博客來
Measures of static and dynamic alignment in individuals with osteoarthritis of the knee.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Measures of static and dynamic alignment in individuals with osteoarthritis of the knee./
作者:
Hunt, Michael Anthony.
面頁冊數:
153 p.
附註:
Source: Dissertation Abstracts International, Volume: 69-02, Section: B, page: 0980.
Contained By:
Dissertation Abstracts International69-02B.
標題:
Health Sciences, Rehabilitation and Therapy. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR36700
ISBN:
9780494367001
Measures of static and dynamic alignment in individuals with osteoarthritis of the knee.
Hunt, Michael Anthony.
Measures of static and dynamic alignment in individuals with osteoarthritis of the knee.
- 153 p.
Source: Dissertation Abstracts International, Volume: 69-02, Section: B, page: 0980.
Thesis (Ph.D.)--The University of Western Ontario (Canada), 2007.
Keywords. knee osteoarthritis, gait, biomechanics, adduction moment, alignment
ISBN: 9780494367001Subjects--Topical Terms:
1017926
Health Sciences, Rehabilitation and Therapy.
Measures of static and dynamic alignment in individuals with osteoarthritis of the knee.
LDR
:03288nmm 2200277 a 45
001
874008
005
20100823
008
100823s2007 ||||||||||||||||| ||eng d
020
$a
9780494367001
035
$a
(UMI)AAINR36700
035
$a
AAINR36700
040
$a
UMI
$c
UMI
100
1
$a
Hunt, Michael Anthony.
$3
1043256
245
1 0
$a
Measures of static and dynamic alignment in individuals with osteoarthritis of the knee.
300
$a
153 p.
500
$a
Source: Dissertation Abstracts International, Volume: 69-02, Section: B, page: 0980.
502
$a
Thesis (Ph.D.)--The University of Western Ontario (Canada), 2007.
520
$a
Keywords. knee osteoarthritis, gait, biomechanics, adduction moment, alignment
520
$a
Results from this thesis describe new aspects of knee joint biomechanics in individuals with knee OA and provide a rationale for the use of measures of dynamic alignment in the study and treatment of knee OA.
520
$a
Several interventions for knee osteoarthritis (OA) are aimed at altering lower limb alignment to reduce joint load during dynamic activities such as walking. The planning of these interventions, however, typically focuses on measures of static alignment that may not adequately represent dynamic situations. Therefore, the purposes of this thesis were to: (1) highlight limitations in using measures of static alignment, and (2) introduce and evaluate novel measures of dynamic alignment for possible use in interventions for patients with knee OA.
520
$a
Five studies involving radiographic measures and three-dimensional gait analyses obtained from patients with knee OA were performed. Findings suggested that the static mechanical axis angle was affected by changing foot positioning during radiograph acquisition. Although the static mechanical axis angle explained a significant portion of variance in the external knee adduction moment during gait---an indirect measure of dynamic medial compartment knee joint load---the addition of gait kinematics such as toe-out and lateral trunk lean angles increased the amount of explained variance substantially. Negative correlations between the knee adduction moment and toe-out and trunk lean angles suggested these kinematics have the potential to reduce knee joint load during gait. Two new measures of dynamic lower limb alignment based on gait analysis were examined: (1) a measure obtained from reflective markers used to quantify hip, knee, and ankle centres, termed marker-based alignment, and (2) the perpendicular distance between the knee joint centre and the ground reaction force vector, termed the frontal plane lever arm. These measures of dynamic alignment were highly correlated with the static mechanical axis angle and the knee adduction moment, indicating they were valid measures of alignment and were associated with knee joint loading. However, only the dynamic lever arm measure was consistently correlated to toe-out and lateral trunk lean. Lastly, all measures of static and dynamic alignment and knee joint load were significantly improved after high tibial osteotomy surgery.
590
$a
School code: 0784.
650
4
$a
Health Sciences, Rehabilitation and Therapy.
$3
1017926
690
$a
0382
710
2
$a
The University of Western Ontario (Canada).
$3
1017622
773
0
$t
Dissertation Abstracts International
$g
69-02B.
790
$a
0784
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR36700
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9079561
電子資源
11.線上閱覽_V
電子書
EB W9079561
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入