語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
到查詢結果
[ subject:"Engineering, Architectural." ]
切換:
標籤
|
MARC模式
|
ISBD
Double-skin facade in hot-arid clima...
~
Alahmed, Zakarya A.
FindBook
Google Book
Amazon
博客來
Double-skin facade in hot-arid climates Computer simulation to find optimized energy and thermal performance of double skin facades.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Double-skin facade in hot-arid climates Computer simulation to find optimized energy and thermal performance of double skin facades./
作者:
Alahmed, Zakarya A.
面頁冊數:
203 p.
附註:
Source: Masters Abstracts International, Volume: 52-03.
Contained By:
Masters Abstracts International52-03(E).
標題:
Architecture. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1546696
ISBN:
9781303466311
Double-skin facade in hot-arid climates Computer simulation to find optimized energy and thermal performance of double skin facades.
Alahmed, Zakarya A.
Double-skin facade in hot-arid climates Computer simulation to find optimized energy and thermal performance of double skin facades.
- 203 p.
Source: Masters Abstracts International, Volume: 52-03.
Thesis (M.B.S.)--University of Southern California, 2013.
Due to the vast development in construction in hot-arid climate areas, implementing innovative facade technologies is crucial to meet owners and developer needs, and to meet climate conditions requirements. Buildings are major contributors of energy consumption due to the high glazing areas and their role of increasing cooling demand. Double skin facades are used in cold and temperate climates to reduce heating loads and for other benefits; however, it's believed that a double skin facade can reduce cooling loads in hot-arid climates. This research project aims to find optimized configurations for double skin facades in this climate. Therefore, by implementing fully glazed double skin facades in hot-arid climate areas with careful design, buildings' energy consumption can be reduced by greater than 10% compared to a single skin facade with high glazing area. Dynamic thermal analysis using IES-VE has been performed on a hypothetical office building in Riyadh city, Saudi Arabia, to simulate baseline and double skin scenarios to examine the performance of proposed variables. Variables include double skin facade typologies: Multi-story, corridor, and box-window, orientation of the facade, cavity depths: 100cm and 150cm, and ventilation type inside the cavity: natural and mechanical. Results showed that rooms adjacent to cavities in different scenarios have lower solar gain, lower cooling load, and improved surface temperature compared to the same rooms in baseline cases. Based on the findings, double skin facades that can reduce energy consumption provide improved thermal performance and help to increase comfort levels. All double skin facade scenarios showed improved performance comparing to the baseline cases. Box-window types show substantial improvement over all other scenarios. And scenarios with mechanically ventilated cavities provided the most improved results in terms of energy and thermal performance.
ISBN: 9781303466311Subjects--Topical Terms:
523581
Architecture.
Double-skin facade in hot-arid climates Computer simulation to find optimized energy and thermal performance of double skin facades.
LDR
:02876nam a2200289 4500
001
1958304
005
20140412123323.5
008
150210s2013 ||||||||||||||||| ||eng d
020
$a
9781303466311
035
$a
(MiAaPQ)AAI1546696
035
$a
AAI1546696
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Alahmed, Zakarya A.
$3
2093348
245
1 0
$a
Double-skin facade in hot-arid climates Computer simulation to find optimized energy and thermal performance of double skin facades.
300
$a
203 p.
500
$a
Source: Masters Abstracts International, Volume: 52-03.
500
$a
Adviser: Douglas Noble.
502
$a
Thesis (M.B.S.)--University of Southern California, 2013.
520
$a
Due to the vast development in construction in hot-arid climate areas, implementing innovative facade technologies is crucial to meet owners and developer needs, and to meet climate conditions requirements. Buildings are major contributors of energy consumption due to the high glazing areas and their role of increasing cooling demand. Double skin facades are used in cold and temperate climates to reduce heating loads and for other benefits; however, it's believed that a double skin facade can reduce cooling loads in hot-arid climates. This research project aims to find optimized configurations for double skin facades in this climate. Therefore, by implementing fully glazed double skin facades in hot-arid climate areas with careful design, buildings' energy consumption can be reduced by greater than 10% compared to a single skin facade with high glazing area. Dynamic thermal analysis using IES-VE has been performed on a hypothetical office building in Riyadh city, Saudi Arabia, to simulate baseline and double skin scenarios to examine the performance of proposed variables. Variables include double skin facade typologies: Multi-story, corridor, and box-window, orientation of the facade, cavity depths: 100cm and 150cm, and ventilation type inside the cavity: natural and mechanical. Results showed that rooms adjacent to cavities in different scenarios have lower solar gain, lower cooling load, and improved surface temperature compared to the same rooms in baseline cases. Based on the findings, double skin facades that can reduce energy consumption provide improved thermal performance and help to increase comfort levels. All double skin facade scenarios showed improved performance comparing to the baseline cases. Box-window types show substantial improvement over all other scenarios. And scenarios with mechanically ventilated cavities provided the most improved results in terms of energy and thermal performance.
590
$a
School code: 0208.
650
4
$a
Architecture.
$3
523581
650
4
$a
Engineering, Architectural.
$3
1671790
650
4
$a
Sustainability.
$3
1029978
690
$a
0729
690
$a
0462
690
$a
0640
710
2
$a
University of Southern California.
$b
Architecture.
$3
1018574
773
0
$t
Masters Abstracts International
$g
52-03(E).
790
$a
0208
791
$a
M.B.S.
792
$a
2013
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1546696
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9253132
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入