Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
The effect of cold, acceleration and...
~
McMullin, Dianne Lynn.
Linked to FindBook
Google Book
Amazon
博客來
The effect of cold, acceleration and frequency on the circulatory and sensory systems of the hand and the transmission of acceleration through the hand and arm.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
The effect of cold, acceleration and frequency on the circulatory and sensory systems of the hand and the transmission of acceleration through the hand and arm./
Author:
McMullin, Dianne Lynn.
Description:
200 p.
Notes:
Adviser: David J. Cochran.
Contained By:
Dissertation Abstracts International55-10B.
Subject:
Engineering, Biomedical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9507819
The effect of cold, acceleration and frequency on the circulatory and sensory systems of the hand and the transmission of acceleration through the hand and arm.
McMullin, Dianne Lynn.
The effect of cold, acceleration and frequency on the circulatory and sensory systems of the hand and the transmission of acceleration through the hand and arm.
- 200 p.
Adviser: David J. Cochran.
Thesis (Ph.D.)--The University of Nebraska - Lincoln, 1994.
Approximately 1.4 million persons are affected by hand-arm vibration in the United States with prevalences of vibration syndrome ranging from 6 to 100% in persons exposed to vibration. The disease affects the peripheral vascular and neural systems and may be associated with musculo-skeletal damage, hearing loss, and carpal tunnel syndrome. The study determined the amount of vibrational acceleration transmitted from a known emission source through the upper limb by the use of accelerometers mounted to the skin at the 3rd metacarpophalangeal joint, the ulnar styloid process, the olecranon and the acromion of the right arm. Three levels of acceleration (4, 16, and 100 m/s$\sp2$), three levels of frequency (67, 163, and 1000 Hz), and three levels of ambient temperature (45, 57.5, and 70$\sp\circ$ F) along with two gender levels were used as independent variables. Input acceleration and input frequency were found to have a significant effect on the transmission of acceleration. Measurements at the metacarpophalangeal joint for 63 and 160 Hz found that the ratios of output to input acceleration were greater than 1.0 indicating that measurements taken only on the tool may underestimate the actual risk to the worker. Also investigated were the effects the independent variables had on blood flow, as measured by finger temperature, vibration sensation thresholds, and subjective ratings of discomfort, tingling and numbness. Ambient temperature had a significant effect upon the changes in finger temperature, vibration sensation threshold and ratings of tingling but not on ratings of numbness and discomfort. A significant but small correlation was found between the transmission of acceleration and vibration threshold sensation and ratings of tingling, numbness and discomfort. The results of the study indicate a need to reevaluate the current ISO and ANSI standards concerning hand-arm vibration exposure.Subjects--Topical Terms:
1017684
Engineering, Biomedical.
The effect of cold, acceleration and frequency on the circulatory and sensory systems of the hand and the transmission of acceleration through the hand and arm.
LDR
:02894nam 2200277 a 45
001
967759
005
20110915
008
110915s1994 eng d
035
$a
(UMI)AAI9507819
035
$a
AAI9507819
040
$a
UMI
$c
UMI
100
1
$a
McMullin, Dianne Lynn.
$3
1291631
245
1 4
$a
The effect of cold, acceleration and frequency on the circulatory and sensory systems of the hand and the transmission of acceleration through the hand and arm.
300
$a
200 p.
500
$a
Adviser: David J. Cochran.
500
$a
Source: Dissertation Abstracts International, Volume: 55-10, Section: B, page: 4545.
502
$a
Thesis (Ph.D.)--The University of Nebraska - Lincoln, 1994.
520
$a
Approximately 1.4 million persons are affected by hand-arm vibration in the United States with prevalences of vibration syndrome ranging from 6 to 100% in persons exposed to vibration. The disease affects the peripheral vascular and neural systems and may be associated with musculo-skeletal damage, hearing loss, and carpal tunnel syndrome. The study determined the amount of vibrational acceleration transmitted from a known emission source through the upper limb by the use of accelerometers mounted to the skin at the 3rd metacarpophalangeal joint, the ulnar styloid process, the olecranon and the acromion of the right arm. Three levels of acceleration (4, 16, and 100 m/s$\sp2$), three levels of frequency (67, 163, and 1000 Hz), and three levels of ambient temperature (45, 57.5, and 70$\sp\circ$ F) along with two gender levels were used as independent variables. Input acceleration and input frequency were found to have a significant effect on the transmission of acceleration. Measurements at the metacarpophalangeal joint for 63 and 160 Hz found that the ratios of output to input acceleration were greater than 1.0 indicating that measurements taken only on the tool may underestimate the actual risk to the worker. Also investigated were the effects the independent variables had on blood flow, as measured by finger temperature, vibration sensation thresholds, and subjective ratings of discomfort, tingling and numbness. Ambient temperature had a significant effect upon the changes in finger temperature, vibration sensation threshold and ratings of tingling but not on ratings of numbness and discomfort. A significant but small correlation was found between the transmission of acceleration and vibration threshold sensation and ratings of tingling, numbness and discomfort. The results of the study indicate a need to reevaluate the current ISO and ANSI standards concerning hand-arm vibration exposure.
590
$a
School code: 0138.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Engineering, Industrial.
$3
626639
650
4
$a
Health Sciences, Medicine and Surgery.
$3
1017756
690
$a
0541
690
$a
0546
690
$a
0564
710
2 0
$a
The University of Nebraska - Lincoln.
$3
1024939
773
0
$t
Dissertation Abstracts International
$g
55-10B.
790
$a
0138
790
1 0
$a
Cochran, David J.,
$e
advisor
791
$a
Ph.D.
792
$a
1994
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9507819
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9126413
電子資源
11.線上閱覽_V
電子書
EB W9126413
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login