Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Airborne pollutant spatial distribut...
~
Jerez, Sheryll Buena.
Linked to FindBook
Google Book
Amazon
博客來
Airborne pollutant spatial distribution, emission, and ventilation effectiveness for mechanically ventilated livestock buildings.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Airborne pollutant spatial distribution, emission, and ventilation effectiveness for mechanically ventilated livestock buildings./
Author:
Jerez, Sheryll Buena.
Description:
276 p.
Notes:
Adviser: Yuanhui Zhang.
Contained By:
Dissertation Abstracts International68-11B.
Subject:
Engineering, Agricultural. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3290261
ISBN:
9780549341994
Airborne pollutant spatial distribution, emission, and ventilation effectiveness for mechanically ventilated livestock buildings.
Jerez, Sheryll Buena.
Airborne pollutant spatial distribution, emission, and ventilation effectiveness for mechanically ventilated livestock buildings.
- 276 p.
Adviser: Yuanhui Zhang.
Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2007.
The spatial distribution of pollutants indoors has not been adequately addressed in the literature primarily due to tedium, high experimental cost, and lack of funding. Yet, this information is essential in the design of pollutant control measures and ventilation systems in buildings. The spatial distributions of particles and gases, as well as the emission and effectiveness of ventilation systems, were studied by conducting field and laboratory experiments and computational fluid dynamics (CFD) simulation.
ISBN: 9780549341994Subjects--Topical Terms:
1019504
Engineering, Agricultural.
Airborne pollutant spatial distribution, emission, and ventilation effectiveness for mechanically ventilated livestock buildings.
LDR
:03289nam 2200301 a 45
001
951275
005
20110609
008
110609s2007 ||||||||||||||||| ||eng d
020
$a
9780549341994
035
$a
(UMI)AAI3290261
035
$a
AAI3290261
040
$a
UMI
$c
UMI
100
1
$a
Jerez, Sheryll Buena.
$3
1275254
245
1 0
$a
Airborne pollutant spatial distribution, emission, and ventilation effectiveness for mechanically ventilated livestock buildings.
300
$a
276 p.
500
$a
Adviser: Yuanhui Zhang.
500
$a
Source: Dissertation Abstracts International, Volume: 68-11, Section: B, page: 7466.
502
$a
Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2007.
520
$a
The spatial distribution of pollutants indoors has not been adequately addressed in the literature primarily due to tedium, high experimental cost, and lack of funding. Yet, this information is essential in the design of pollutant control measures and ventilation systems in buildings. The spatial distributions of particles and gases, as well as the emission and effectiveness of ventilation systems, were studied by conducting field and laboratory experiments and computational fluid dynamics (CFD) simulation.
520
$a
The results of experiments in a mechanically ventilated swine building showed that the spatial distribution of particulate matter (PM) and ammonia (NH3) concentrations differed in winter and summer due to the different airflow patterns. The PM concentration was more likely to vary crosswise in winter and lengthwise in summer within the building. The concentration of NH3, on the other hand, tended to vary more lengthwise in winter and was distributed almost uniformly in summer. These results are important in the strategic location of samplers in the building.
520
$a
Laboratory experiments were conducted to determine how the type of ventilation system and the levels of ventilation rate affect the spatial distribution of pollutants. Carbon dioxide (CO2) was used as a tracer gas to represent the transport of other gases. The type of ventilation system had a significant effect on the spatial distribution of both particles and CO 2. The ventilation rate, on the other hand, had no substantial effect on the spatial distribution of both pollutants. In addition, increased in ventilation rate decreased the removal effectiveness for PM possibly due to resuspension of particles. Increasing the ventilation rate, however, resulted in increased contaminant removal effectiveness for CO2.
520
$a
CFD simulation was used to predict the spatial distribution of particles less than 10 mum in diameter (PM10) in the swine building. Results showed that the magnitude of the predicted concentrations was significantly higher than the measured concentrations which could be attributed to the assumption of the particle generation rate. Thus, the CFD will be useful as a simulation tool in the future if the particle variables (e.g., particle generation rate, particle velocity) in the model can be properly quantified.
590
$a
School code: 0090.
650
4
$a
Engineering, Agricultural.
$3
1019504
690
$a
0539
710
2
$a
University of Illinois at Urbana-Champaign.
$3
626646
773
0
$t
Dissertation Abstracts International
$g
68-11B.
790
$a
0090
790
1 0
$a
Zhang, Yuanhui,
$e
advisor
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3290261
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9118146
電子資源
11.線上閱覽_V
電子書
EB W9118146
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login