Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Real-time processing of three dimens...
~
Novotny, Paul Martin.
Linked to FindBook
Google Book
Amazon
博客來
Real-time processing of three dimensional ultrasound for intracardiac surgery.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Real-time processing of three dimensional ultrasound for intracardiac surgery./
Author:
Novotny, Paul Martin.
Description:
90 p.
Notes:
Adviser: Robert D. Howe.
Contained By:
Dissertation Abstracts International68-05B.
Subject:
Engineering, Biomedical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3265055
ISBN:
9780549036753
Real-time processing of three dimensional ultrasound for intracardiac surgery.
Novotny, Paul Martin.
Real-time processing of three dimensional ultrasound for intracardiac surgery.
- 90 p.
Adviser: Robert D. Howe.
Thesis (Ph.D.)--Harvard University, 2007.
Real-time three-dimensional ultrasound has been demonstrated as a viable tool for guiding surgical procedures. This visualization technique enables a range of new minimally invasive techniques in cardiac surgery. Ultrasound permits visualization through the opaque blood pool in the heart, and the advent of real-time 3DUS overcomes difficulties with 3D spatial perception in conventional 2D ultrasound. These procedures eliminate the need for a cardiopulminary bypass and its well documented adverse effects. However, challenges remain before clinical implementation of ultrasound-guided intracardiac surgery can be made practical. 3D ultrasound provides limited spatial perception due to distorted appearance of tissue and instruments. The low quality imaging when combined with the confined dynamic environment of a beating heart makes complex tasks difficult for surgeons to perform.
ISBN: 9780549036753Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Real-time processing of three dimensional ultrasound for intracardiac surgery.
LDR
:03073nam 2200289 a 45
001
947932
005
20110524
008
110524s2007 ||||||||||||||||| ||eng d
020
$a
9780549036753
035
$a
(UMI)AAI3265055
035
$a
AAI3265055
040
$a
UMI
$c
UMI
100
1
$a
Novotny, Paul Martin.
$3
1271396
245
1 0
$a
Real-time processing of three dimensional ultrasound for intracardiac surgery.
300
$a
90 p.
500
$a
Adviser: Robert D. Howe.
500
$a
Source: Dissertation Abstracts International, Volume: 68-05, Section: B, page: 3203.
502
$a
Thesis (Ph.D.)--Harvard University, 2007.
520
$a
Real-time three-dimensional ultrasound has been demonstrated as a viable tool for guiding surgical procedures. This visualization technique enables a range of new minimally invasive techniques in cardiac surgery. Ultrasound permits visualization through the opaque blood pool in the heart, and the advent of real-time 3DUS overcomes difficulties with 3D spatial perception in conventional 2D ultrasound. These procedures eliminate the need for a cardiopulminary bypass and its well documented adverse effects. However, challenges remain before clinical implementation of ultrasound-guided intracardiac surgery can be made practical. 3D ultrasound provides limited spatial perception due to distorted appearance of tissue and instruments. The low quality imaging when combined with the confined dynamic environment of a beating heart makes complex tasks difficult for surgeons to perform.
520
$a
These challenges are addressed by improving the display of 3D ultrasound with stereo displays, tracked surgical instruments, and introducing robotics for handling the dynamic cardiac tissue. A study is presented that demonstrates stereo displays improve surgical performance, reducing error rates by 50% and procedure times by 28%. The stereo display was found to help surgeons better interpret the low resolution ultrasound volumes. However, a large source of ultrasound distortion is imaging artifacts created by surgical instruments. A detection technique is presented that identifies the position of the instrument within the ultrasound volume. The algorithm uses a form of the generalized Radon transform and passive markers to identify the full position and orientation of the instrument. This detection technique is amenable to rapid execution on parallel computer architectures and as a result real-time instrument tracking was attained. With a tracked instrument location, it is now possible to develop enhanced surgical displays. Instrument tracking also enables robot guidance that is ideally suited to compensate for the highly dynamic environment of beating heart surgery. A system has been designed and tested that uses real-time instrument and target tracking for robot control.
590
$a
School code: 0084.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Engineering, Robotics.
$3
1018454
690
$a
0541
690
$a
0771
710
2
$a
Harvard University.
$3
528741
773
0
$t
Dissertation Abstracts International
$g
68-05B.
790
$a
0084
790
1 0
$a
Howe, Robert D.,
$e
advisor
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3265055
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9115659
電子資源
11.線上閱覽_V
電子書
EB W9115659
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login