A comparison of the kinematic response and biofidelity of the neck of pediatric cadaver data and the Hybrid III three-year-old child finite element model.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
A comparison of the kinematic response and biofidelity of the neck of pediatric cadaver data and the Hybrid III three-year-old child finite element model./
Author:
Tot, Miroslav Joseph.
Description:
83 p.
Notes:
Source: Masters Abstracts International, Volume: 46-04, page: 2004.
Contained By:
Masters Abstracts International46-04.
Subject:
Biology, Physiology. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=MR35174
ISBN:
9780494351741
A comparison of the kinematic response and biofidelity of the neck of pediatric cadaver data and the Hybrid III three-year-old child finite element model.
Tot, Miroslav Joseph.
A comparison of the kinematic response and biofidelity of the neck of pediatric cadaver data and the Hybrid III three-year-old child finite element model.
- 83 p.
Source: Masters Abstracts International, Volume: 46-04, page: 2004.
Thesis (M.H.K.)--University of Windsor (Canada), 2007.
This research focuses on comparing the kinematic response of the head and neck of the Hybrid III three-year-old anthropometric test device finite element model and pediatric cadaver data under tensile distraction and flexion-extension bending loading conditions. In this work, an explicit finite element code (LS-DYNA) and the Hybrid III finite element model were used to numerically simulate previous experimental cadaver tests. Significant differences in linear and rotational stiffness were found between the Hybrid III and the pediatric cadaver data. The pediatric cadaver data was implemented into the Hybrid III model and loaded with a crash pulse obtained from experimental child cadaver sled test. Comparisons of kinematic were made and it was found that the altered model exhibited a 31 percent greater degree of head rotation, a 141 percent greater degree of chest deflection, and the head trajectory more closely resembled that of the experimental pediatric cadaver sled test.
ISBN: 9780494351741Subjects--Topical Terms:
1017816
Biology, Physiology.
A comparison of the kinematic response and biofidelity of the neck of pediatric cadaver data and the Hybrid III three-year-old child finite element model.
LDR
:01825nam 2200241 a 45
001
947129
005
20110523
008
110523s2007 ||||||||||||||||| ||eng d
020
$a
9780494351741
035
$a
(UMI)AAIMR35174
035
$a
AAIMR35174
040
$a
UMI
$c
UMI
100
1
$a
Tot, Miroslav Joseph.
$3
1270547
245
1 2
$a
A comparison of the kinematic response and biofidelity of the neck of pediatric cadaver data and the Hybrid III three-year-old child finite element model.
300
$a
83 p.
500
$a
Source: Masters Abstracts International, Volume: 46-04, page: 2004.
502
$a
Thesis (M.H.K.)--University of Windsor (Canada), 2007.
520
$a
This research focuses on comparing the kinematic response of the head and neck of the Hybrid III three-year-old anthropometric test device finite element model and pediatric cadaver data under tensile distraction and flexion-extension bending loading conditions. In this work, an explicit finite element code (LS-DYNA) and the Hybrid III finite element model were used to numerically simulate previous experimental cadaver tests. Significant differences in linear and rotational stiffness were found between the Hybrid III and the pediatric cadaver data. The pediatric cadaver data was implemented into the Hybrid III model and loaded with a crash pulse obtained from experimental child cadaver sled test. Comparisons of kinematic were made and it was found that the altered model exhibited a 31 percent greater degree of head rotation, a 141 percent greater degree of chest deflection, and the head trajectory more closely resembled that of the experimental pediatric cadaver sled test.
590
$a
School code: 0115.
650
4
$a
Biology, Physiology.
$3
1017816
690
$a
0719
710
2
$a
University of Windsor (Canada).
$3
1018526
773
0
$t
Masters Abstracts International
$g
46-04.
790
$a
0115
791
$a
M.H.K.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=MR35174
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9114933
電子資源
11.線上閱覽_V
電子書
EB W9114933
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login