Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Quantitative detection of Escherichi...
~
Guan, Jiewen.
Linked to FindBook
Google Book
Amazon
博客來
Quantitative detection of Escherichia coli O157:H7 in ground beef by the polymerase chain reaction incorporating immunomagnetic separation.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Quantitative detection of Escherichia coli O157:H7 in ground beef by the polymerase chain reaction incorporating immunomagnetic separation./
Author:
Guan, Jiewen.
Description:
121 p.
Notes:
Director: Robert E. Levin.
Contained By:
Dissertation Abstracts International63-01B.
Subject:
Agriculture, Food Science and Technology. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3039361
ISBN:
0493525823
Quantitative detection of Escherichia coli O157:H7 in ground beef by the polymerase chain reaction incorporating immunomagnetic separation.
Guan, Jiewen.
Quantitative detection of Escherichia coli O157:H7 in ground beef by the polymerase chain reaction incorporating immunomagnetic separation.
- 121 p.
Director: Robert E. Levin.
Thesis (Ph.D.)--University of Massachusetts Amherst, 2002.
<italic>Escherichia coli</italic> O157:H7 is an important foodborne pathogen. The majority of outbreaks of this organism have been attributed to ground beef. In order to improve the sensitivity for detection of <italic> E. coli</italic> O157:H7 in ground beef by the polymerase chain reaction (PCR), sample preparation methods including differential centrifugation, enrichment, immunomagnetic separation (IMS), and DNA extraction were studied. Quantitative detection protocols based on standard PCR, nested PCR and competitive PCR were developed.
ISBN: 0493525823Subjects--Topical Terms:
1017813
Agriculture, Food Science and Technology.
Quantitative detection of Escherichia coli O157:H7 in ground beef by the polymerase chain reaction incorporating immunomagnetic separation.
LDR
:03183nam 2200313 a 45
001
937920
005
20110511
008
110511s2002 eng d
020
$a
0493525823
035
$a
(UnM)AAI3039361
035
$a
AAI3039361
040
$a
UnM
$c
UnM
100
1
$a
Guan, Jiewen.
$3
1261776
245
1 0
$a
Quantitative detection of Escherichia coli O157:H7 in ground beef by the polymerase chain reaction incorporating immunomagnetic separation.
300
$a
121 p.
500
$a
Director: Robert E. Levin.
500
$a
Source: Dissertation Abstracts International, Volume: 63-01, Section: B, page: 0006.
502
$a
Thesis (Ph.D.)--University of Massachusetts Amherst, 2002.
520
$a
<italic>Escherichia coli</italic> O157:H7 is an important foodborne pathogen. The majority of outbreaks of this organism have been attributed to ground beef. In order to improve the sensitivity for detection of <italic> E. coli</italic> O157:H7 in ground beef by the polymerase chain reaction (PCR), sample preparation methods including differential centrifugation, enrichment, immunomagnetic separation (IMS), and DNA extraction were studied. Quantitative detection protocols based on standard PCR, nested PCR and competitive PCR were developed.
520
$a
Using standard PCR enabled detection of 150 colony forming units (CFU) per gram of ground beef without enrichment and 1.2 CFU/g after 4.5 h of enrichment in modified EC broth plus novobiocin (mEC+n) with SLT I and SLT II primers respectively. The quantitative detection range was 150 to 15,000 CFU/g for protocol without enrichment and 1.2 to 19.2 CFU/g for protocol with enrichment.
520
$a
Standard PCR incorporating IMS detected 70 CFU/g with SLT I and SLT II primers without enrichment and 0.7 CFU/g after 6 h of enrichment in Tryptic Soy Broth (TSB) and IMS. The quantitative detection range was 70 to 24,000 CFU/g for protocol without enrichment and 0.7 to 70 CFU/g for protocol with enrichment. A partial digestion of the cell pellets derived from differential centrifugation was required for IMS. DNA extracted from seeded target cells captured by IMB could be used for PCR amplification without further purification.
520
$a
Nested PCR incorporating differential centrifugation and IMS was capable of detecting 2.4 CFU/g with SLT 1 and SLT 2 primers without enrichment. Within the range of 2.4 to 240 CFU/g, a linear relationship between the log CFU of the inocula and the fluorescent intensity of secondary PCR products was achieved by using 25 cycles for both primary and secondary PCR run.
520
$a
Competitive PCR incorporating IMS enabled quantitative detection of 0.5 to 5.5 CFU per gram of ground beef with SLT I and SLT II primers after 6 hours of enrichment using TSB. The numbers of target organisms after enrichment and IMS determined by competitive PCR were highly correlated to those derived from viable plate counts on violet red bile agar.
590
$a
School code: 0118.
650
4
$a
Agriculture, Food Science and Technology.
$3
1017813
690
$a
0359
710
2 0
$a
University of Massachusetts Amherst.
$3
1019433
773
0
$t
Dissertation Abstracts International
$g
63-01B.
790
$a
0118
790
1 0
$a
Levin, Robert E.,
$e
advisor
791
$a
Ph.D.
792
$a
2002
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3039361
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9108407
電子資源
11.線上閱覽_V
電子書
EB W9108407
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login