Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Development and application of needl...
~
University of Waterloo (Canada).
Linked to FindBook
Google Book
Amazon
博客來
Development and application of needle trap device.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Development and application of needle trap device./
Author:
Gong, Ying.
Description:
91 p.
Notes:
Source: Masters Abstracts International, Volume: 47-03, page: .
Contained By:
Masters Abstracts International47-03.
Subject:
Chemistry, Analytical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=MR43668
ISBN:
9780494436684
Development and application of needle trap device.
Gong, Ying.
Development and application of needle trap device.
- 91 p.
Source: Masters Abstracts International, Volume: 47-03, page: .
Thesis (M.Sc.)--University of Waterloo (Canada), 2008.
Air is one of the most important resources in the world and is essential for life. With the development of industry, air pollution is becoming a severe problem. Air Pollution not only affects the quality of the air we breathe; it also impacts the land and the water. Volatile organic compounds (VOCs), which can cause short-term and long-term health problems, are found as contaminants in both indoor air and the environment. Therefore, it is necessary to develop accurate and convenient sampling methods to determine VOCs at trace levels in both community and occupational environment. The focus of this project is to develop the needle trap devices (NTDs) with appropriate sorbents and employ them to do air samplings by diffusive or active sampling mode. For diffusive sampling, the NTD with sorbent Carboxen1000 was developed to monitor benzene, toluene, ethylbenzene and o-xylene (BTEX) in the air, coupled with GC-MS. The factors such as sorbent strength, response time, face velocity, temperature and pressure, relative humidity and sampling duration were investigated. Method validations were done both in the laboratory and in field. The results demonstrate that the NTD with Carboxen1000 is a successful diffusive sampler for monitoring Time-weighted average (TWA) concentrations of BTEX. On the other hand, the NTD with divinylbenzene (DVB) coupled with GC-MS by thermal desorption was developed for sampling and analysis of volatile thiols. The factors such as sorbent strength, desorption efficiency were investigated. The applications, such as vegetable analysis and field sampling analysis, indicate that the NTD with sorbent DVB is a successful active sampler for determine volatile thiols in food and air samples.
ISBN: 9780494436684Subjects--Topical Terms:
586156
Chemistry, Analytical.
Development and application of needle trap device.
LDR
:02459nmm 2200241 a 45
001
867373
005
20100804
008
100804s2008 ||||||||||||||||| ||eng d
020
$a
9780494436684
035
$a
(UMI)AAIMR43668
035
$a
AAIMR43668
040
$a
UMI
$c
UMI
100
1
$a
Gong, Ying.
$3
1036103
245
1 0
$a
Development and application of needle trap device.
300
$a
91 p.
500
$a
Source: Masters Abstracts International, Volume: 47-03, page: .
502
$a
Thesis (M.Sc.)--University of Waterloo (Canada), 2008.
520
$a
Air is one of the most important resources in the world and is essential for life. With the development of industry, air pollution is becoming a severe problem. Air Pollution not only affects the quality of the air we breathe; it also impacts the land and the water. Volatile organic compounds (VOCs), which can cause short-term and long-term health problems, are found as contaminants in both indoor air and the environment. Therefore, it is necessary to develop accurate and convenient sampling methods to determine VOCs at trace levels in both community and occupational environment. The focus of this project is to develop the needle trap devices (NTDs) with appropriate sorbents and employ them to do air samplings by diffusive or active sampling mode. For diffusive sampling, the NTD with sorbent Carboxen1000 was developed to monitor benzene, toluene, ethylbenzene and o-xylene (BTEX) in the air, coupled with GC-MS. The factors such as sorbent strength, response time, face velocity, temperature and pressure, relative humidity and sampling duration were investigated. Method validations were done both in the laboratory and in field. The results demonstrate that the NTD with Carboxen1000 is a successful diffusive sampler for monitoring Time-weighted average (TWA) concentrations of BTEX. On the other hand, the NTD with divinylbenzene (DVB) coupled with GC-MS by thermal desorption was developed for sampling and analysis of volatile thiols. The factors such as sorbent strength, desorption efficiency were investigated. The applications, such as vegetable analysis and field sampling analysis, indicate that the NTD with sorbent DVB is a successful active sampler for determine volatile thiols in food and air samples.
590
$a
School code: 1141.
650
4
$a
Chemistry, Analytical.
$3
586156
690
$a
0486
710
2
$a
University of Waterloo (Canada).
$3
1017669
773
0
$t
Masters Abstracts International
$g
47-03.
790
$a
1141
791
$a
M.Sc.
792
$a
2008
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=MR43668
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9078851
電子資源
11.線上閱覽_V
電子書
EB W9078851
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password