Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
High resolution high field quantitat...
~
University of California, San Francisco., Bioengineering.
Linked to FindBook
Google Book
Amazon
博客來
High resolution high field quantitative parallel magnetic resonance imaging for osteoporosis and other clinical applications.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
High resolution high field quantitative parallel magnetic resonance imaging for osteoporosis and other clinical applications./
Author:
Banerjee, Suchandrima.
Description:
159 p.
Notes:
Adviser: Sharmila Majumdar.
Contained By:
Dissertation Abstracts International68-07B.
Subject:
Engineering, Biomedical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoeng/servlet/advanced?query=3274656
ISBN:
9780549132882
High resolution high field quantitative parallel magnetic resonance imaging for osteoporosis and other clinical applications.
Banerjee, Suchandrima.
High resolution high field quantitative parallel magnetic resonance imaging for osteoporosis and other clinical applications.
- 159 p.
Adviser: Sharmila Majumdar.
Thesis (Ph.D.)--University of California, San Francisco, 2007.
This thesis developed high signal-to-noise ratio (SNR) yielding magnetic resonance imaging (MRI) methods that require relatively short measurement times. The methods were primarily aimed at addressing existing technical limitations of low SNR and long scan times (∼ 20 minutes) in the field of in vivo high resolution (HR) imaging of trabecular bone micro-architecture. HR-MRI of trabecular bone provides a non-invasive way of monitoring trabecular bone structural integrity for assessment of the disease condition, osteoporosis. Osteoporosis is a debilitating skeletal disorder affecting 1 in 3 women and 1 in 12 men over the age of 50 worldwide and is characterized by loss of bone mass and structure leading to atraumatic fractures at the vertebrae, hip, wrists and other sites. SNR limitations in trabecular bone MRI were overcome by incorporating a high magnetization yielding pulse sequence and translating the imaging protocol to the higher field strength of 3 Tesla (T) from the clinical standard of 1.5 T. A simulation model was developed to estimate SNR in bone tissue. The feasibility of imaging trabecular bone structure in vivo at the proximal femur (hip), until then an SNR impeded application, was demonstrated. Next, an autocalibrating parallel imaging (PI) method was implemented to accelerate data acquisition. Using an eight channel coil array, scan time was reduced 2-4 fold without any significant impact on image resolution or edge sharpness; although bone structural measures derived from the accelerated images showed overestimation. Consequently, parallel reconstruction and image processing algorithms were developed to address the causes of overestimation. With the availability of whole body 7 T magnets and the motivation for further improvement in SNR, the PI methods were adapted to the even higher field strength and its performance was found to improve relative to 3 T. To summarize, this thesis developed SNR efficient MR methods that facilitate quantitative HR-MRI of trabecular bone within 2-10 minutes, thus increasing the clinical feasibility of this application. Additionally, the PI methods were applied to diverse applications such as cartilage imaging for osteoarthritis; and susceptibility weighted imaging of brain vasculature and 3D spectroscopic imaging of brain metabolites in brain tumor patients.
ISBN: 9780549132882Subjects--Topical Terms:
1017684
Engineering, Biomedical.
High resolution high field quantitative parallel magnetic resonance imaging for osteoporosis and other clinical applications.
LDR
:03402nam 2200301 a 45
001
858168
005
20100712
008
100712s2007 ||||||||||||||||| ||eng d
020
$a
9780549132882
035
$a
(UMI)AAI3274656
035
$a
AAI3274656
040
$a
UMI
$c
UMI
100
1
$a
Banerjee, Suchandrima.
$3
1025200
245
1 0
$a
High resolution high field quantitative parallel magnetic resonance imaging for osteoporosis and other clinical applications.
300
$a
159 p.
500
$a
Adviser: Sharmila Majumdar.
500
$a
Source: Dissertation Abstracts International, Volume: 68-07, Section: B, page: 4629.
502
$a
Thesis (Ph.D.)--University of California, San Francisco, 2007.
520
$a
This thesis developed high signal-to-noise ratio (SNR) yielding magnetic resonance imaging (MRI) methods that require relatively short measurement times. The methods were primarily aimed at addressing existing technical limitations of low SNR and long scan times (∼ 20 minutes) in the field of in vivo high resolution (HR) imaging of trabecular bone micro-architecture. HR-MRI of trabecular bone provides a non-invasive way of monitoring trabecular bone structural integrity for assessment of the disease condition, osteoporosis. Osteoporosis is a debilitating skeletal disorder affecting 1 in 3 women and 1 in 12 men over the age of 50 worldwide and is characterized by loss of bone mass and structure leading to atraumatic fractures at the vertebrae, hip, wrists and other sites. SNR limitations in trabecular bone MRI were overcome by incorporating a high magnetization yielding pulse sequence and translating the imaging protocol to the higher field strength of 3 Tesla (T) from the clinical standard of 1.5 T. A simulation model was developed to estimate SNR in bone tissue. The feasibility of imaging trabecular bone structure in vivo at the proximal femur (hip), until then an SNR impeded application, was demonstrated. Next, an autocalibrating parallel imaging (PI) method was implemented to accelerate data acquisition. Using an eight channel coil array, scan time was reduced 2-4 fold without any significant impact on image resolution or edge sharpness; although bone structural measures derived from the accelerated images showed overestimation. Consequently, parallel reconstruction and image processing algorithms were developed to address the causes of overestimation. With the availability of whole body 7 T magnets and the motivation for further improvement in SNR, the PI methods were adapted to the even higher field strength and its performance was found to improve relative to 3 T. To summarize, this thesis developed SNR efficient MR methods that facilitate quantitative HR-MRI of trabecular bone within 2-10 minutes, thus increasing the clinical feasibility of this application. Additionally, the PI methods were applied to diverse applications such as cartilage imaging for osteoarthritis; and susceptibility weighted imaging of brain vasculature and 3D spectroscopic imaging of brain metabolites in brain tumor patients.
590
$a
School code: 0034.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Health Sciences, Radiology.
$3
1019076
690
$a
0541
690
$a
0574
710
2
$a
University of California, San Francisco.
$b
Bioengineering.
$3
1025199
773
0
$t
Dissertation Abstracts International
$g
68-07B.
790
$a
0034
790
1 0
$a
Link, Thomas M.
$e
committee member
790
1 0
$a
Majumdar, Sharmila,
$e
advisor
790
1 0
$a
Nelson, Sarah J.
$e
committee member
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoeng/servlet/advanced?query=3274656
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9073044
電子資源
11.線上閱覽_V
電子書
EB W9073044
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login