Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Ultra-high resolution imaging and ar...
~
University of Washington.
Linked to FindBook
Google Book
Amazon
博客來
Ultra-high resolution imaging and artery-vein separation of blood pool contrast-enhanced MRA.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Ultra-high resolution imaging and artery-vein separation of blood pool contrast-enhanced MRA./
Author:
Wang, Maisie S.
Description:
126 p.
Notes:
Adviser: David Haynor.
Contained By:
Dissertation Abstracts International68-02B.
Subject:
Engineering, Biomedical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoeng/servlet/advanced?query=3252902
Ultra-high resolution imaging and artery-vein separation of blood pool contrast-enhanced MRA.
Wang, Maisie S.
Ultra-high resolution imaging and artery-vein separation of blood pool contrast-enhanced MRA.
- 126 p.
Adviser: David Haynor.
Thesis (Ph.D.)--University of Washington, 2007.
Contrast-enhanced magnetic resonance angiography (CE-MRA) is used for diagnosing atherosclerotic peripheral vascular occlusive disease (PVOD). Current methods of CE-MRA use conventional gadolinium (Gd) contrast agents to acquire images of the vasculature during the arterial phase. Accurate timing of the contrast arrival is required and acquisition times are limited due to the short contrast-enhancement window. A new type of Gd-based contrast agent, termed blood pool, has prolonged intravascular half-life and higher relaxivity than conventional Gd contrast agents. Image acquisition is no longer restricted to the dynamic phase. Longer scan times could be utilized for high resolution imaging, which would allow better visualization of the peripheral vasculature and diagnosis of vascular disease. This feature is useful in the lower extremity, where vessels are small (1-6mm in diameter). High resolution imaging occurs in the equilibrium phase (EP), where both arteries and veins are enhanced. Consequently, it is pertinent to distinguish and separate arteries and veins so that the arterial and venous vasculature can be visualized clearly.Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Ultra-high resolution imaging and artery-vein separation of blood pool contrast-enhanced MRA.
LDR
:03457nam 2200301 a 45
001
858158
005
20100712
008
100712s2007 ||||||||||||||||| ||eng d
035
$a
(UMI)AAI3252902
035
$a
AAI3252902
040
$a
UMI
$c
UMI
100
1
$a
Wang, Maisie S.
$3
1025189
245
1 0
$a
Ultra-high resolution imaging and artery-vein separation of blood pool contrast-enhanced MRA.
300
$a
126 p.
500
$a
Adviser: David Haynor.
500
$a
Source: Dissertation Abstracts International, Volume: 68-02, Section: B, page: 1126.
502
$a
Thesis (Ph.D.)--University of Washington, 2007.
520
$a
Contrast-enhanced magnetic resonance angiography (CE-MRA) is used for diagnosing atherosclerotic peripheral vascular occlusive disease (PVOD). Current methods of CE-MRA use conventional gadolinium (Gd) contrast agents to acquire images of the vasculature during the arterial phase. Accurate timing of the contrast arrival is required and acquisition times are limited due to the short contrast-enhancement window. A new type of Gd-based contrast agent, termed blood pool, has prolonged intravascular half-life and higher relaxivity than conventional Gd contrast agents. Image acquisition is no longer restricted to the dynamic phase. Longer scan times could be utilized for high resolution imaging, which would allow better visualization of the peripheral vasculature and diagnosis of vascular disease. This feature is useful in the lower extremity, where vessels are small (1-6mm in diameter). High resolution imaging occurs in the equilibrium phase (EP), where both arteries and veins are enhanced. Consequently, it is pertinent to distinguish and separate arteries and veins so that the arterial and venous vasculature can be visualized clearly.
520
$a
Methods were developed to obtain ultra-high resolution images of the entire vasculature using the blood pool agent Vasovist and to separate those images into the arterial and venous vasculature. First, a model was developed to find optimal MR sequence parameters that maximize contrast-to-noise (CNR) for ultra-high resolution equilibrium phase imaging. An in-plane resolution of 0.5 mm was found to provide the best trade-off between the spatial resolution needed to distinguish arteries from veins and the CNR needed for artery-vein separation and detecting arterial disease.
520
$a
An algorithm to segment distinct arterial and venous vasculatures from the EP MRA images was developed. The algorithm uses a novel feature image that incorporates vessel shape. This feature image can be applied in both Markov random field and level set methods. The algorithm is fast and requires only a small amount of user interaction to initialize and is hence practical for use in a clinical workflow. An image viewing strategy was also devised to alleviate the impact of imperfect segmentation.
520
$a
The entire process from image acquisition through the clinical presentation of images was evaluated for effectiveness in diagnosing PVOD. The segmented EP images compared favorably to the dynamic phase images with high sensitivity and specificity, and significantly improved venous suppression, SNR, and vessel clarity.
590
$a
School code: 0250.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Health Sciences, Radiology.
$3
1019076
690
$a
0541
690
$a
0574
710
2
$a
University of Washington.
$3
545923
773
0
$t
Dissertation Abstracts International
$g
68-02B.
790
$a
0250
790
1 0
$a
Haynor, David,
$e
advisor
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoeng/servlet/advanced?query=3252902
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9073034
電子資源
11.線上閱覽_V
電子書
EB W9073034
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login