A novel air sampling and analytical method for determination of airborne bronopol.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
A novel air sampling and analytical method for determination of airborne bronopol./
Author:
Smyth, John Charles.
Description:
200 p.
Notes:
Adviser: Yehia Y. Hammad.
Contained By:
Dissertation Abstracts International68-01B.
Subject:
Engineering, Environmental. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoeng/servlet/advanced?query=3248310
A novel air sampling and analytical method for determination of airborne bronopol.
Smyth, John Charles.
A novel air sampling and analytical method for determination of airborne bronopol.
- 200 p.
Adviser: Yehia Y. Hammad.
Thesis (Ph.D.)--University of South Florida, 2006.
A calibration curve has been developed with a linear range of 1 microg/ml to 25 microg/ml. The instrumental limit of detection is 1 microg/ml with an instrumental limit of quantitation of ca. 3 microg/ml.Subjects--Topical Terms:
783782
Engineering, Environmental.
A novel air sampling and analytical method for determination of airborne bronopol.
LDR
:03263nam 2200325 a 45
001
858155
005
20100712
008
100712s2006 ||||||||||||||||| ||eng d
035
$a
(UMI)AAI3248310
035
$a
AAI3248310
040
$a
UMI
$c
UMI
100
1
$a
Smyth, John Charles.
$3
1025186
245
1 2
$a
A novel air sampling and analytical method for determination of airborne bronopol.
300
$a
200 p.
500
$a
Adviser: Yehia Y. Hammad.
500
$a
Source: Dissertation Abstracts International, Volume: 68-01, Section: B, page: 0221.
502
$a
Thesis (Ph.D.)--University of South Florida, 2006.
520
$a
A calibration curve has been developed with a linear range of 1 microg/ml to 25 microg/ml. The instrumental limit of detection is 1 microg/ml with an instrumental limit of quantitation of ca. 3 microg/ml.
520
$a
Treated glass fiber filters spiked with bronopol were found to be stable for a period of 48 hours; derivatized bronopol solutions were found to be stable for a period of fourteen days.
520
$a
Bronopol has been used as a preservative in drugs and cosmetics since 1964. Bronopol has low dermal irritancy at levels commonly used in cosmetics and pharmaceuticals but it is significantly irritating at higher concentrations. Laboratory testing of bronopol indicates a low potential for dermal sensitization; however, a number of case reports demonstrate human allergenic reactions. No reports were identified on the allergenic properties of bronopol for the inhalation route of exposure.
520
$a
In 1983 approximately 5,200 people in the United States were occupationally exposed to bronopol. Current novel uses of bronopol include mold remediation and the sanitizing of ventilation system components. These new applications have the potential to expose vast new populations to the chemical. Since 89 million people in the United States work in indoor environments and 50 million Americans suffer from allergies, it is likely that a sizeable portion of these populations will be exposed to bronopol. This is significant since the dermal sensitizing properties of bronopol suggest that the material may also be a respiratory sensitizer, potentially resulting in chemically induced asthma. More people are being diagnosed with asthma today than at any time in the past; the causes of this increased prevalence are largely unknown.
520
$a
In this work an existing ultraviolet spectrophotometric method for analysis of bronopol has been combined with conventional industrial hygiene air sampling techniques. No combined air sampling and analytical method for bronopol has previously been published in the literature.
520
$a
During chamber sampling trials analytical recovery for treated glass fiber filters yielded a sampling recovery efficiency averaging 99.9 %. Bronopol concentration obtained during chamber sampling trials ranged from 10.80 mg/m³ to 21.59 mg/m³, with a pooled coefficient of variation of 4.33% for all chamber sampling sets.
590
$a
School code: 0206.
650
4
$a
Engineering, Environmental.
$3
783782
650
4
$a
Health Sciences, Occupational Health and Safety.
$3
1017799
690
$a
0354
690
$a
0775
710
2
$a
University of South Florida.
$3
1020446
773
0
$t
Dissertation Abstracts International
$g
68-01B.
790
$a
0206
790
1 0
$a
Hammad, Yehia Y.,
$e
advisor
791
$a
Ph.D.
792
$a
2006
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoeng/servlet/advanced?query=3248310
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9073031
電子資源
11.線上閱覽_V
電子書
EB W9073031
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login