Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Comparison of microdialysis with sol...
~
University of Waterloo (Canada).
Linked to FindBook
Google Book
Amazon
博客來
Comparison of microdialysis with solid-phase microextraction for in vivo study.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Comparison of microdialysis with solid-phase microextraction for in vivo study./
Author:
Zhou, Simon Ningsun.
Description:
230 p.
Notes:
Source: Dissertation Abstracts International, Volume: 69-11, Section: B, page: 6763.
Contained By:
Dissertation Abstracts International69-11B.
Subject:
Chemistry, Analytical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR43395
ISBN:
9780494433959
Comparison of microdialysis with solid-phase microextraction for in vivo study.
Zhou, Simon Ningsun.
Comparison of microdialysis with solid-phase microextraction for in vivo study.
- 230 p.
Source: Dissertation Abstracts International, Volume: 69-11, Section: B, page: 6763.
Thesis (Ph.D.)--University of Waterloo (Canada), 2008.
Although microdialysis (MD) and solid-phase microextraction (SPME) are widely used sampling techniques, a comparison study has not been performed to date. The goal of the research presented was not only to address this issue but also to develop new analytical methods that were more suitable for in vivo study using MD and SPME.
ISBN: 9780494433959Subjects--Topical Terms:
586156
Chemistry, Analytical.
Comparison of microdialysis with solid-phase microextraction for in vivo study.
LDR
:05777nam 2200301 a 45
001
855246
005
20100708
008
100708s2008 ||||||||||||||||| ||eng d
020
$a
9780494433959
035
$a
(UMI)AAINR43395
035
$a
AAINR43395
040
$a
UMI
$c
UMI
100
1
$a
Zhou, Simon Ningsun.
$3
1021804
245
1 0
$a
Comparison of microdialysis with solid-phase microextraction for in vivo study.
300
$a
230 p.
500
$a
Source: Dissertation Abstracts International, Volume: 69-11, Section: B, page: 6763.
502
$a
Thesis (Ph.D.)--University of Waterloo (Canada), 2008.
520
$a
Although microdialysis (MD) and solid-phase microextraction (SPME) are widely used sampling techniques, a comparison study has not been performed to date. The goal of the research presented was not only to address this issue but also to develop new analytical methods that were more suitable for in vivo study using MD and SPME.
520
$a
A new calibration method called kinetic microdialysis was developed for in vivo sampling. Two MD probes with different flow rates were simultaneously inserted into the symmetric parts of sampling system. A simple empirical equation was proposed to calculate the analyte concentrations in the sample matrix using two different dialysate concentrations. Several factors that influenced the correction factor in this equation were discussed. An excellent correlation was observed between the calculated and theoretical value. This method was subsequently applied for in vivo sampling, for the measurement of pesticide allocation in the different leaves of a jade plant ( Crassula ovata). Compared to the other reported MD calibration methods, this novel approach offers several advantages including simplicity, speed, robustness, and increased accuracy.
520
$a
The on-fiber standardization technique for solid-coated SPME was studied and a theoretical model is proposed for the isotropic behavior of adsorption and desorption, based on Fick's law of diffusion and the Langmuir model. The isotropy of the adsorption and desorption of analytes onto and from the surface of porous solid SPME fiber was validated with the use of a commercially available fiber, a 50 mum carbowax/templated resin (CW/TPR) for carbamate pesticide analysis in various in vitro sample matrices. Time constants were comparable for the adsorption and desorption processes. Equilibrium constants and fiber capacities were calculated with the Langmuir Isotherm Model. A kinetic method was developed to calibrate adsorption using desorption. This calibration corrected for the sample matrix effects and minimized displacement effects as a pre-equilibrium extraction. The technique was successfully applied to the analysis of pesticides in river water and white wine. This developed method could be potentially applied for in vivo study.
520
$a
A new kinetic calibration was developed using dominant pre-equilibrium desorption by SPME. The calibration was based on isotropism between absorption and desorption, which was proved theoretically and experimentally in an aqueous solution and semi-solid matrix. This approach allows for the calibration of absorption using desorption to compensate for matrix effects. Moreover, concentration profiles are initially proposed to verify isotropism between the absorption and desorption, while providing a linear approach to obtain time constants for the purpose of quantitative analysis. This linear approach is more convenient, robust and accurate than the non-linear version with the previously used time profiles. Furthermore, the target analytes are used as the internal standards, thus radioactive or deuterated internal standards are not necessary. In addition, dominant pre-equilibrium desorption utilizes the pre-equilibrium approach and offers a shorter sample preparation time, which is typically suitable for in vivo sampling. This kinetic calibration method was successfully applied to prepare samples of polycyclic aromatic hydrocarbons (PAHs) in a flow-through system and in vivo pesticide sampling in a jade plant (Crassula ovata).
520
$a
In this study, SPME was developed for in vivo laboratory and field sampling of pharmaceuticals in fish muscle. Pre-equilibrium extraction was used to shorten in vivo sampling time. The use of pre-equilibrium desorption rates are proposed as a means to calibrate pre-equilibrium extractions. Based on this study, SPME technique has demonstrated several important advantages for laboratory and field in vivo sampling. The development of a rapid, robust, easy to deploy technique which combines sampling, extraction and concentration into one step is a potentially important tool for use in vivo field-based sampling.
520
$a
MD and SPME methods have been developed and compared through in vitro and in vivo study. For in vitro study (juice, milk and orange jelly), both methods offered accurate and precise results (recovery: 88-105% with RSD < 15%) for complex sample matrices by standard addition method. The limits of quantification (LOQs) of the two methods developed were below the tolerance levels in milk set by the United Nations Food and Agriculture Organization (FAO). Compared to MD, the fully automated SPME procedure offered several advantages including high-throughput and more efficient sampling, less labor intensity, and capability for batch analysis. For in vivo study, kinetic calibrations were performed using retrodialysis and in-fiber standardization techniques for MD and SPME, respectively. (Abstract shortened by UMI.)
590
$a
School code: 1141.
650
4
$a
Chemistry, Analytical.
$3
586156
690
$a
0486
710
2
$a
University of Waterloo (Canada).
$3
1017669
773
0
$t
Dissertation Abstracts International
$g
69-11B.
790
$a
1141
791
$a
Ph.D.
792
$a
2008
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR43395
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9070583
電子資源
11.線上閱覽_V
電子書
EB W9070583
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login