Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Radiometric modeling of mechanical d...
~
Rochester Institute of Technology., Imaging Science.
Linked to FindBook
Google Book
Amazon
博客來
Radiometric modeling of mechanical draft cooling towers to assist in the extraction of their absolute temperature from remote thermal imagery.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Radiometric modeling of mechanical draft cooling towers to assist in the extraction of their absolute temperature from remote thermal imagery./
Author:
Montanaro, Matthew.
Description:
209 p.
Notes:
Adviser: Carl Salvaggio.
Contained By:
Dissertation Abstracts International70-04B.
Subject:
Remote Sensing. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3354721
ISBN:
9781109118971
Radiometric modeling of mechanical draft cooling towers to assist in the extraction of their absolute temperature from remote thermal imagery.
Montanaro, Matthew.
Radiometric modeling of mechanical draft cooling towers to assist in the extraction of their absolute temperature from remote thermal imagery.
- 209 p.
Adviser: Carl Salvaggio.
Thesis (Ph.D.)--Rochester Institute of Technology, 2009.
Determination of the internal temperature of a mechanical draft cooling tower (MDCT) from remotely-sensed thermal imagery is important for many applications that provide input to energy-related process models. The problem of determining the temperature of an MDCT is unique due to the geometry of the tower and due to the exhausted water vapor plume. The radiance leaving the tower is dependent on the optical and thermal properties of the tower materials ( i.e., emissivity, BRDF, temperature, etc.) as well as the internal geometry of the tower. The tower radiance is then propagated through the exhaust plume and through the atmosphere to arrive at the sensor. The expelled effluent from the tower consists of a warm plume with a higher water vapor concentration than the ambient atmosphere. Given that a thermal image has been atmospherically compensated, the remaining sources of error in extracted tower temperature due to the exhausted plume and the tower geometry must be accounted for. A temperature correction factor due to these error sources is derived through the use of three-dimensional radiometric modeling. A range of values for each important parameter are modeled to create a target space (i.e. , look-up table) that predicts the internal MDCT temperature for every combination of parameter values. The look-up table provides data for the creation of a fast-running parameterized model. This model, along with user knowledge of the scene, provides a means to convert the image-derived apparent temperature into the estimated absolute temperature of an MDCT.
ISBN: 9781109118971Subjects--Topical Terms:
1018559
Remote Sensing.
Radiometric modeling of mechanical draft cooling towers to assist in the extraction of their absolute temperature from remote thermal imagery.
LDR
:02665nam 2200301 a 45
001
853276
005
20100701
008
100701s2009 ||||||||||||||||| ||eng d
020
$a
9781109118971
035
$a
(UMI)AAI3354721
035
$a
AAI3354721
040
$a
UMI
$c
UMI
100
1
$a
Montanaro, Matthew.
$3
1019512
245
1 0
$a
Radiometric modeling of mechanical draft cooling towers to assist in the extraction of their absolute temperature from remote thermal imagery.
300
$a
209 p.
500
$a
Adviser: Carl Salvaggio.
500
$a
Source: Dissertation Abstracts International, Volume: 70-04, Section: B, page: .
502
$a
Thesis (Ph.D.)--Rochester Institute of Technology, 2009.
520
$a
Determination of the internal temperature of a mechanical draft cooling tower (MDCT) from remotely-sensed thermal imagery is important for many applications that provide input to energy-related process models. The problem of determining the temperature of an MDCT is unique due to the geometry of the tower and due to the exhausted water vapor plume. The radiance leaving the tower is dependent on the optical and thermal properties of the tower materials ( i.e., emissivity, BRDF, temperature, etc.) as well as the internal geometry of the tower. The tower radiance is then propagated through the exhaust plume and through the atmosphere to arrive at the sensor. The expelled effluent from the tower consists of a warm plume with a higher water vapor concentration than the ambient atmosphere. Given that a thermal image has been atmospherically compensated, the remaining sources of error in extracted tower temperature due to the exhausted plume and the tower geometry must be accounted for. A temperature correction factor due to these error sources is derived through the use of three-dimensional radiometric modeling. A range of values for each important parameter are modeled to create a target space (i.e. , look-up table) that predicts the internal MDCT temperature for every combination of parameter values. The look-up table provides data for the creation of a fast-running parameterized model. This model, along with user knowledge of the scene, provides a means to convert the image-derived apparent temperature into the estimated absolute temperature of an MDCT.
590
$a
School code: 0465.
650
4
$a
Remote Sensing.
$3
1018559
690
$a
0799
710
2
$a
Rochester Institute of Technology.
$b
Imaging Science.
$3
1019498
773
0
$t
Dissertation Abstracts International
$g
70-04B.
790
$a
0465
790
1 0
$a
Garrett, Alfred J.
$e
committee member
790
1 0
$a
Hensel, Edward C.
$e
committee member
790
1 0
$a
Messinger, David W.
$e
committee member
790
1 0
$a
Salvaggio, Carl,
$e
advisor
791
$a
Ph.D.
792
$a
2009
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3354721
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9069795
電子資源
11.線上閱覽_V
電子書
EB W9069795
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login