Numerical Investigation of NAPL Depl...
~
Cheng, Shih-Yang,
FindBook
Google Book
Amazon
博客來
Numerical Investigation of NAPL Depletion and Back Diffusion Mitigation Through In Situ Persulfate Oxidation /
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Numerical Investigation of NAPL Depletion and Back Diffusion Mitigation Through In Situ Persulfate Oxidation // Shih-Yang Cheng.
作者:
Cheng, Shih-Yang,
面頁冊數:
1 electronic resource (76 pages)
附註:
Source: Masters Abstracts International, Volume: 86-05.
Contained By:
Masters Abstracts International86-05.
標題:
Environmental engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31562721
ISBN:
9798342756457
Numerical Investigation of NAPL Depletion and Back Diffusion Mitigation Through In Situ Persulfate Oxidation /
Cheng, Shih-Yang,
Numerical Investigation of NAPL Depletion and Back Diffusion Mitigation Through In Situ Persulfate Oxidation /
Shih-Yang Cheng. - 1 electronic resource (76 pages)
Source: Masters Abstracts International, Volume: 86-05.
Persulfate, noted for its high oxidative potential and prolonged persistence, is increasingly being utilized for groundwater remediation purposes. A reactive transport model was utilized to evaluate the effectiveness of persulfate oxidation in non-aqueous phase liquid (NAPL) depletion and back diffusion mitigation of trichloroethylene (TCE). The model, incorporating NAPL dissolution and persulfate chemistry, was validated against previously published experimental data and subsequently applied to two illustrative cases, which were used to examine the influence of various design parameters and soil oxidant demand (SOD) on contaminant removal. Findings indicate that high oxidant concentration and slow groundwater velocity are preferred for both NAPL depletion and back diffusion mitigation. High temperature can benefit NAPL depletion while low temperature is suitable for back diffusion mitigation. Understanding site-specific SOD values is critical for evaluating ISCO performance. This study highlights the importance of optimizing design parameters and considering site-specific conditions to improve the effectiveness of TCE remediation efforts.
English
ISBN: 9798342756457Subjects--Topical Terms:
548583
Environmental engineering.
Subjects--Index Terms:
Back diffusion
Numerical Investigation of NAPL Depletion and Back Diffusion Mitigation Through In Situ Persulfate Oxidation /
LDR
:02582nmm a22004453i 4500
001
2438871
005
20260727135843.5
006
m o d
007
cr|nu||||||||
008
261011s2024 miu||||||m |||||||eng d
020
$a
9798342756457
035
$a
(MiAaPQD)AAI31562721
035
$a
AAI31562721
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Cheng, Shih-Yang,
$e
author.
$0
(orcid)0009-0008-7053-045X
$3
3830300
245
1 0
$a
Numerical Investigation of NAPL Depletion and Back Diffusion Mitigation Through In Situ Persulfate Oxidation /
$c
Shih-Yang Cheng.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2024
300
$a
1 electronic resource (76 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 86-05.
500
$a
Advisors: Sleep, Brent.
502
$b
M.A.S.
$c
University of Toronto (Canada)
$d
2024.
520
$a
Persulfate, noted for its high oxidative potential and prolonged persistence, is increasingly being utilized for groundwater remediation purposes. A reactive transport model was utilized to evaluate the effectiveness of persulfate oxidation in non-aqueous phase liquid (NAPL) depletion and back diffusion mitigation of trichloroethylene (TCE). The model, incorporating NAPL dissolution and persulfate chemistry, was validated against previously published experimental data and subsequently applied to two illustrative cases, which were used to examine the influence of various design parameters and soil oxidant demand (SOD) on contaminant removal. Findings indicate that high oxidant concentration and slow groundwater velocity are preferred for both NAPL depletion and back diffusion mitigation. High temperature can benefit NAPL depletion while low temperature is suitable for back diffusion mitigation. Understanding site-specific SOD values is critical for evaluating ISCO performance. This study highlights the importance of optimizing design parameters and considering site-specific conditions to improve the effectiveness of TCE remediation efforts.
546
$a
English
590
$a
School code: 0779
650
4
$a
Environmental engineering.
$3
548583
650
4
$a
Mineralogy.
$3
516743
653
$a
Back diffusion
653
$a
ISCO performance
653
$a
NAPL dissolution
653
$a
Numerical modeling
653
$a
Persulfate oxidation
653
$a
Trichloroethylene
690
$a
0775
690
$a
0543
690
$a
0411
710
2
$a
University of Toronto (Canada).
$b
Civil Engineering.
$e
degree granting institution.
$3
3816485
720
1
$a
Sleep, Brent
$e
degree supervisor.
773
0
$t
Masters Abstracts International
$g
86-05.
790
$a
0779
791
$a
M.A.S.
792
$a
2024
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31562721
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9534566
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入