Investigation of Flow Past Cylinder ...
~
Bista, Sabal,
Linked to FindBook
Google Book
Amazon
博客來
Investigation of Flow Past Cylinder Placed Near a Bed /
Record Type:
Electronic resources : Monograph/item
Title/Author:
Investigation of Flow Past Cylinder Placed Near a Bed // Sabal Bista.
Author:
Bista, Sabal,
Description:
1 electronic resource (73 pages)
Notes:
Source: Masters Abstracts International, Volume: 86-04.
Contained By:
Masters Abstracts International86-04.
Subject:
Fluid mechanics. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31563394
ISBN:
9798384475828
Investigation of Flow Past Cylinder Placed Near a Bed /
Bista, Sabal,
Investigation of Flow Past Cylinder Placed Near a Bed /
Sabal Bista. - 1 electronic resource (73 pages)
Source: Masters Abstracts International, Volume: 86-04.
This study investigates the impact of gap ratio and Reynolds number on the wake dynamics of flow past a horizontal cylinder using Particle Image Velocimetry. The gap ratios (ratio of gap size, \uD835\uDC3A to cylinder diameter, \uD835\uDC51 ) examined were 0.50,1.0, and 1.5 at Reynolds number of 3960 and 0.25, 0.50, and 1.0, at Reynolds number of 7930. The findings reveal that a decreasing gap ratio results in an asymmetrical wake due to the stretching of the bottom cylinder shear layer and an increase in recirculation length behind the cylinder due to reduced entrainment. Additionally, the recirculation region length decreases with increasing Reynolds number due to enhanced mixing and momentum transfer. No recirculation zone near the bed was observed for the Reynolds numbers considered. Proper Orthogonal Decomposition (POD) analysis showed reduced energy contribution of the first two modes with decreasing gap ratio, reflecting the breakdown of large coherent structures due to the bed interaction. The reconstructed flow field indicated suppression of vortex shedding from the bottom cylinder shear layer for gap ratios less than 0.50. These results suggest that gap ratio is a more critical parameter than absolute gap size in determining flow structures, with minimal effect from Reynolds number. 
English
ISBN: 9798384475828Subjects--Topical Terms:
528155
Fluid mechanics.
Subjects--Index Terms:
Gap flow
Investigation of Flow Past Cylinder Placed Near a Bed /
LDR
:02749nmm a22004453i 4500
001
2438686
005
20260727134409.5
006
m o d
007
cr|nu||||||||
008
261011s2024 miu||||||m |||||||eng d
020
$a
9798384475828
035
$a
(MiAaPQD)AAI31563394
035
$a
AAI31563394
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Bista, Sabal,
$e
author.
$3
3830061
245
1 0
$a
Investigation of Flow Past Cylinder Placed Near a Bed /
$c
Sabal Bista.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2024
300
$a
1 electronic resource (73 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 86-04.
500
$a
Advisors: Nasif, G.; Balachandar, R. Committee members: Shinneeb, M.; Barron, R.
502
$b
M.A.Sc.
$c
University of Windsor (Canada)
$d
2024.
520
$a
This study investigates the impact of gap ratio and Reynolds number on the wake dynamics of flow past a horizontal cylinder using Particle Image Velocimetry. The gap ratios (ratio of gap size, \uD835\uDC3A to cylinder diameter, \uD835\uDC51 ) examined were 0.50,1.0, and 1.5 at Reynolds number of 3960 and 0.25, 0.50, and 1.0, at Reynolds number of 7930. The findings reveal that a decreasing gap ratio results in an asymmetrical wake due to the stretching of the bottom cylinder shear layer and an increase in recirculation length behind the cylinder due to reduced entrainment. Additionally, the recirculation region length decreases with increasing Reynolds number due to enhanced mixing and momentum transfer. No recirculation zone near the bed was observed for the Reynolds numbers considered. Proper Orthogonal Decomposition (POD) analysis showed reduced energy contribution of the first two modes with decreasing gap ratio, reflecting the breakdown of large coherent structures due to the bed interaction. The reconstructed flow field indicated suppression of vortex shedding from the bottom cylinder shear layer for gap ratios less than 0.50. These results suggest that gap ratio is a more critical parameter than absolute gap size in determining flow structures, with minimal effect from Reynolds number. 
546
$a
English
590
$a
School code: 0115
650
4
$a
Fluid mechanics.
$3
528155
650
4
$a
Engineering.
$3
586835
650
4
$a
Materials science.
$3
543314
650
4
$a
Mechanical engineering.
$3
649730
653
$a
Gap flow
653
$a
Particle Image Velocimetry
653
$a
Reynolds number
653
$a
Cylinder shear layer
690
$a
0204
690
$a
0794
690
$a
0537
690
$a
0548
710
2
$a
University of Windsor (Canada).
$b
MECHANICAL ENGINEERING.
$e
degree granting institution.
$3
3819042
720
1
$a
Nasif, G.
$e
degree supervisor.
720
1
$a
Balachandar, R.
$e
degree supervisor.
773
0
$t
Masters Abstracts International
$g
86-04.
790
$a
0115
791
$a
M.A.Sc.
792
$a
2024
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31563394
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9534381
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login