Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Comparative Shade Measurement Analys...
~
Rattanapian, Parinda,
Linked to FindBook
Google Book
Amazon
博客來
Comparative Shade Measurement Analysis Between Visual Assessment, Intraoral Scanner and Vita EasyShade /
Record Type:
Electronic resources : Monograph/item
Title/Author:
Comparative Shade Measurement Analysis Between Visual Assessment, Intraoral Scanner and Vita EasyShade // Parinda Rattanapian.
Author:
Rattanapian, Parinda,
Description:
1 electronic resource (60 pages)
Notes:
Source: Masters Abstracts International, Volume: 85-11.
Contained By:
Masters Abstracts International85-11.
Subject:
Dentistry. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31292886
ISBN:
9798382726632
Comparative Shade Measurement Analysis Between Visual Assessment, Intraoral Scanner and Vita EasyShade /
Rattanapian, Parinda,
Comparative Shade Measurement Analysis Between Visual Assessment, Intraoral Scanner and Vita EasyShade /
Parinda Rattanapian. - 1 electronic resource (60 pages)
Source: Masters Abstracts International, Volume: 85-11.
Aim & Hypothesis:This research aimed to perform a comparative analysis of shade measurement methods in dentistry, focusing on the accuracy of a digital scanning system (Trios 4) in comparison with traditional visual determination with Vita Classical and Vita 3D Master shade guides, using a handheld spectrophotometer (Vita EasyShade) as the reference standard. The null hypothesis was that there would be no difference in the shade matching outcomes between the methods.Materials & Methods:In a controlled clinical setting, 25 teeth were assessed for color matching using the Vita EasyShade device to establish reference values. The same teeth were then measured with the Trios 4 scanner. A diverse group of twenty examiners, including ten dental students and ten experienced dentists, utilized Vita Classical and Vita 3D Master shade guides to determine the shade that best matched each tooth. The ΔE values were calculated and compared with the thresholds of acceptability and perceptibility for color match precision.Results:When applying the more stringent acceptability/perceptibility threshold of 1.8, a mere 14.6% of 714 observations were in agreement with the Vita Easyshade measurements. Notably, the success rate of matches varied slightly across different groups, with the lowest being the Vita Classical and 3D Master guide indications by the Trios 4 scanner at 11.8%, and the highest being the student group using Vita Classical and 3D Master at 15.3%. These differences, however, did not reach statistical significance (p = 0.994). The analysis conducted at the threshold of 3.6 demonstrated an overall agreement rate of 42.6%, with individual group performance ranging from 38.4% to 64.0%, still maintaining statistical non-significance (p = 0.135).Conclusions:In the study of shade matching efficacy, the comparative analysis between digital assessment using the Trios 4 scanner and conventional visual evaluation with Vita Classical and Vita3D Master shade guides did not show statistically significant differences. The anticipated enhancement in consistency and reliability with digital methods, as per prior expectations, was not substantiated with empirical evidence within the parameters of this study. It is particularly noteworthy that when a decision threshold of 1.8 was used, the data did not demonstrate a definitive trend in favor of the digital approach. These findings imply that current advancements in digital shade determination technology have not yet reached a level of development that conclusively surpasses traditional methods in the practice of aesthetic dentistry. As such, this research underscores the essentiality of ongoing development in digital dental technologies and presents a tempered perspective on the immediate integration of such methods. Further inquiries are warranted to establish the specific conditions under which digital methods might indeed exhibit significant improvements, thereby justifying a methodological shift in the field.
English
ISBN: 9798382726632Subjects--Topical Terms:
828971
Dentistry.
Subjects--Index Terms:
Color analysis
Comparative Shade Measurement Analysis Between Visual Assessment, Intraoral Scanner and Vita EasyShade /
LDR
:04506nmm a22004333i 4500
001
2438211
005
20251210113946.5
006
m o d
007
cr|nu||||||||
008
261011s2024 miu||||||m |||||||eng d
020
$a
9798382726632
035
$a
(MiAaPQD)AAI31292886
035
$a
AAI31292886
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Rattanapian, Parinda,
$e
author.
$3
3829449
245
1 0
$a
Comparative Shade Measurement Analysis Between Visual Assessment, Intraoral Scanner and Vita EasyShade /
$c
Parinda Rattanapian.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2024
300
$a
1 electronic resource (60 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 85-11.
500
$a
Advisors: Mahn Arteaga, Gustavo Committee members: Finkelman, Matthew; Papathanasiou, Aikaterini; Molina Rojas, Giovanni.
502
$b
M.S.
$c
Tufts University School of Dental Medicine
$d
2024.
520
$a
Aim & Hypothesis:This research aimed to perform a comparative analysis of shade measurement methods in dentistry, focusing on the accuracy of a digital scanning system (Trios 4) in comparison with traditional visual determination with Vita Classical and Vita 3D Master shade guides, using a handheld spectrophotometer (Vita EasyShade) as the reference standard. The null hypothesis was that there would be no difference in the shade matching outcomes between the methods.Materials & Methods:In a controlled clinical setting, 25 teeth were assessed for color matching using the Vita EasyShade device to establish reference values. The same teeth were then measured with the Trios 4 scanner. A diverse group of twenty examiners, including ten dental students and ten experienced dentists, utilized Vita Classical and Vita 3D Master shade guides to determine the shade that best matched each tooth. The ΔE values were calculated and compared with the thresholds of acceptability and perceptibility for color match precision.Results:When applying the more stringent acceptability/perceptibility threshold of 1.8, a mere 14.6% of 714 observations were in agreement with the Vita Easyshade measurements. Notably, the success rate of matches varied slightly across different groups, with the lowest being the Vita Classical and 3D Master guide indications by the Trios 4 scanner at 11.8%, and the highest being the student group using Vita Classical and 3D Master at 15.3%. These differences, however, did not reach statistical significance (p = 0.994). The analysis conducted at the threshold of 3.6 demonstrated an overall agreement rate of 42.6%, with individual group performance ranging from 38.4% to 64.0%, still maintaining statistical non-significance (p = 0.135).Conclusions:In the study of shade matching efficacy, the comparative analysis between digital assessment using the Trios 4 scanner and conventional visual evaluation with Vita Classical and Vita3D Master shade guides did not show statistically significant differences. The anticipated enhancement in consistency and reliability with digital methods, as per prior expectations, was not substantiated with empirical evidence within the parameters of this study. It is particularly noteworthy that when a decision threshold of 1.8 was used, the data did not demonstrate a definitive trend in favor of the digital approach. These findings imply that current advancements in digital shade determination technology have not yet reached a level of development that conclusively surpasses traditional methods in the practice of aesthetic dentistry. As such, this research underscores the essentiality of ongoing development in digital dental technologies and presents a tempered perspective on the immediate integration of such methods. Further inquiries are warranted to establish the specific conditions under which digital methods might indeed exhibit significant improvements, thereby justifying a methodological shift in the field.
546
$a
English
590
$a
School code: 1547
650
4
$a
Dentistry.
$3
828971
650
4
$a
Medicine.
$3
641104
653
$a
Color analysis
653
$a
Dental aesthetics
653
$a
Digital dentistry
653
$a
Shade assessment
653
$a
Shade matching
653
$a
Spectrophotometry
690
$a
0567
690
$a
0564
710
2
$a
Tufts University School of Dental Medicine.
$b
Other.
$e
degree granting institution.
$3
3828557
720
1
$a
Mahn Arteaga, Gustavo
$e
degree supervisor.
773
0
$t
Masters Abstracts International
$g
85-11.
790
$a
1547
791
$a
M.S.
792
$a
2024
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31292886
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9533906
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login