Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
The Biomechanical Influence of Trans...
~
Vandenberg, Nicholas William,
Linked to FindBook
Google Book
Amazon
博客來
The Biomechanical Influence of Transfemoral Bone-Anchored Limb Use and Predictive Modeling Applications for Enhancing Clinical Efficacy /
Record Type:
Electronic resources : Monograph/item
Title/Author:
The Biomechanical Influence of Transfemoral Bone-Anchored Limb Use and Predictive Modeling Applications for Enhancing Clinical Efficacy // Nicholas William Vandenberg.
Author:
Vandenberg, Nicholas William,
Description:
1 electronic resource (142 pages)
Notes:
Source: Dissertations Abstracts International, Volume: 86-11, Section: B.
Contained By:
Dissertations Abstracts International86-11B.
Subject:
Mechanical engineering. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=32043935
ISBN:
9798315733577
The Biomechanical Influence of Transfemoral Bone-Anchored Limb Use and Predictive Modeling Applications for Enhancing Clinical Efficacy /
Vandenberg, Nicholas William,
The Biomechanical Influence of Transfemoral Bone-Anchored Limb Use and Predictive Modeling Applications for Enhancing Clinical Efficacy /
Nicholas William Vandenberg. - 1 electronic resource (142 pages)
Source: Dissertations Abstracts International, Volume: 86-11, Section: B.
People with unilateral transfemoral amputations often demonstrate compensatory movement patterns while using socket-type prostheses, resulting in asymmetrical joint loading that increases the risk of developing secondary comorbidities such as osteoarthritis or low-back pain. Bone-anchored limbs (BALs), which attach prostheses directly to the residual limb using osseointegrated implants, have shown promise in improving mobility, muscle function, and overall quality of life. However, there remains a need to better understand the biomechanical outcomes of BAL use. The objective of this dissertation was to assess the longitudinal biomechanical effects of transfemoral BAL use and utilize predictive modeling tools to aid clinical application.Three Specific Aims guided this work. The first aim developed subject-specific musculoskeletal models to evaluate longitudinal changes in gait biomechanics before and after BAL implantation. This included a novel six degree-of-freedom residuum-socket interface for socket-type prosthesis users. Specific Aim 1 showed that BALs improved muscle function and forward propulsion strategies, but also highlighted that asymmetric joint loading conditions persisted. In the second aim, an optimal control framework was implemented to generate subject-specific gait patterns, joint loading conditions, and muscle activity using BAL models and experimental data. These results were robustly validated to generate solutions to act as baselines for simulated rehabilitative interventions. Specific Aim 2 included test cases investigating the movement pattern and joint loading changes from simulating varied weakened and strengthened conditions of hip abductor muscles. Additionally, a movement pattern retraining intervention was simulated to determine feasibility of symmetrical movement for transfemoral BAL users, and the biomechanical changes resulting from achieving symmetry. Finally, to address limitations of laboratory-based modeling, the third aim used probabilistic analysis to assess the sensitivity of predicted joint moments to perturbations in physical parameters of Hunt-Crossley contact spheres; within an optimal control framework driven by wearable sensor kinematic data.Collectively, this work presents a range of computational tools (including musculoskeletal modeling, optimal control, and probabilistic analyses) which could potentially aid in promoting clinical accessibility to computational biomechanics to inform high-cost clinical trials and help develop patient-specific rehabilitation strategies for transfemoral BAL users.
English
ISBN: 9798315733577Subjects--Topical Terms:
649730
Mechanical engineering.
Subjects--Index Terms:
Inertial measurement unit
The Biomechanical Influence of Transfemoral Bone-Anchored Limb Use and Predictive Modeling Applications for Enhancing Clinical Efficacy /
LDR
:04311nmm a22004813i 4500
001
2436096
005
20251021115111.5
006
m o d
007
cr|nu||||||||
008
261011s2025 miu||||||m |||||||eng d
020
$a
9798315733577
035
$a
(MiAaPQD)AAI32043935
035
$a
AAI32043935
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Vandenberg, Nicholas William,
$e
author.
$3
3826636
245
1 0
$a
The Biomechanical Influence of Transfemoral Bone-Anchored Limb Use and Predictive Modeling Applications for Enhancing Clinical Efficacy /
$c
Nicholas William Vandenberg.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2025
300
$a
1 electronic resource (142 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 86-11, Section: B.
500
$a
Advisors: Gaffney, Brecca M. M.; Carpenter, R. Dana Committee members: Christiansen, Cory L.; Al Borno, Mazen; Wheatley, Benjamin.
502
$b
Ph.D.
$c
University of Colorado at Denver
$d
2025.
520
$a
People with unilateral transfemoral amputations often demonstrate compensatory movement patterns while using socket-type prostheses, resulting in asymmetrical joint loading that increases the risk of developing secondary comorbidities such as osteoarthritis or low-back pain. Bone-anchored limbs (BALs), which attach prostheses directly to the residual limb using osseointegrated implants, have shown promise in improving mobility, muscle function, and overall quality of life. However, there remains a need to better understand the biomechanical outcomes of BAL use. The objective of this dissertation was to assess the longitudinal biomechanical effects of transfemoral BAL use and utilize predictive modeling tools to aid clinical application.Three Specific Aims guided this work. The first aim developed subject-specific musculoskeletal models to evaluate longitudinal changes in gait biomechanics before and after BAL implantation. This included a novel six degree-of-freedom residuum-socket interface for socket-type prosthesis users. Specific Aim 1 showed that BALs improved muscle function and forward propulsion strategies, but also highlighted that asymmetric joint loading conditions persisted. In the second aim, an optimal control framework was implemented to generate subject-specific gait patterns, joint loading conditions, and muscle activity using BAL models and experimental data. These results were robustly validated to generate solutions to act as baselines for simulated rehabilitative interventions. Specific Aim 2 included test cases investigating the movement pattern and joint loading changes from simulating varied weakened and strengthened conditions of hip abductor muscles. Additionally, a movement pattern retraining intervention was simulated to determine feasibility of symmetrical movement for transfemoral BAL users, and the biomechanical changes resulting from achieving symmetry. Finally, to address limitations of laboratory-based modeling, the third aim used probabilistic analysis to assess the sensitivity of predicted joint moments to perturbations in physical parameters of Hunt-Crossley contact spheres; within an optimal control framework driven by wearable sensor kinematic data.Collectively, this work presents a range of computational tools (including musculoskeletal modeling, optimal control, and probabilistic analyses) which could potentially aid in promoting clinical accessibility to computational biomechanics to inform high-cost clinical trials and help develop patient-specific rehabilitation strategies for transfemoral BAL users.
546
$a
English
590
$a
School code: 0765
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Biomechanics.
$3
548685
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Physical therapy.
$3
588713
650
4
$a
Kinesiology.
$3
517627
653
$a
Inertial measurement unit
653
$a
Musculoskeletal modeling
653
$a
Optimal control
653
$a
Osseointegration
653
$a
Rehabilitation
653
$a
Transfemoral amputations
690
$a
0548
690
$a
0648
690
$a
0541
690
$a
0575
690
$a
0382
710
2
$a
University of Colorado at Denver.
$b
Engineering and Applied Science.
$e
degree granting institution.
$3
3826637
720
1
$a
Gaffney, Brecca M. M.
$e
degree supervisor.
720
1
$a
Carpenter, R. Dana
$e
degree supervisor.
773
0
$t
Dissertations Abstracts International
$g
86-11B.
790
$a
0765
791
$a
Ph.D.
792
$a
2025
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=32043935
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9531791
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login