Development of a Prototype AWSM-PET System for Augmented Whole-Body PET Imaging /
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Development of a Prototype AWSM-PET System for Augmented Whole-Body PET Imaging // Yunlai Chen.
作者:
Chen, Yunlai,
面頁冊數:
1 electronic resource (152 pages)
附註:
Source: Dissertations Abstracts International, Volume: 86-10, Section: B.
Contained By:
Dissertations Abstracts International86-10B.
標題:
Electrical engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31848708
ISBN:
9798310388765
Development of a Prototype AWSM-PET System for Augmented Whole-Body PET Imaging /
Chen, Yunlai,
Development of a Prototype AWSM-PET System for Augmented Whole-Body PET Imaging /
Yunlai Chen. - 1 electronic resource (152 pages)
Source: Dissertations Abstracts International, Volume: 86-10, Section: B.
Positron Emission Tomography (PET) is a critical imaging modality for medical diagnostics, yet its accuracy is often limited by spatial resolution and sensitivity constraints. This dissertation presents the development of Augmented Whole-body Scan via Magnifying PET (AWSM-PET), a novel technique integrating high-resolution auxiliary detectors with a clinical PET scanner to enhance sensitivity and resolution while remaining fully compatible with standard clinical protocols. The study encompasses hardware development, image reconstruction methods, and performance evaluation through imaging studies, including human trials.High-resolution outsert panel detectors were designed, mounted on a mobile cart, and integrated with a Biograph Vision PET/CT scanner. Firmware and software modifications enabled simultaneous data acquisition under clinical protocols. The outsert detectors achieved an energy resolution of 11% full width at half maximum (FWHM) at 511 keV and a coincidence resolving time (CRT) of 183 ps FWHM. Sensitivity improved by up to 18.4%, depending on source location.A data-driven geometric alignment method was developed using point source measurements, achieving sub-millimeter precision without requiring special landmarks or repetitive measurements. This approach optimized the outsert detector positioning to minimize angular discrepancies in detected lines of response (LORs) via an iterative optimization method. Monte Carlo simulations confirmed that the deviation between the ground truth and estimated geometry remained well below 1 mm. Experimental validation demonstrated that point source images using the estimated geometry aligned well with those from the Biograph Vision scanner, with centroid deviations below 1 mm and angular deviations of line source images under 1 degree across the field of view.To support image reconstruction, a Maximum Likelihood Expectation Maximization (MLEM) listmode image reconstruction technique was developed for continuous-bed-motion (CBM) reconstruction in AWSM-PET. To balance reconstruction speed and accuracy, a single-ring approximation and grouped crystal approximation were introduced to accelerate sensitivity image calculation. Scatter and random corrections were implemented to achieve quantitative images, incorporating approximations to optimize computational efficiency. Additionally, a spatially variant point spread function (PSF) model was compared with a spatially invariant model. Rather than enhancing spatial resolution, the PSF model primarily contributes to improving contrast recovery and noise control.AWSM-PET was evaluated through NEMA-IQ, and mini-Derenzo phantoms, as well as human imaging studies. Compared to the Biograph Vision scanner, the mini-Derenzo phantom study demonstrated improved spatial resolution for spherical lesions ≤6 mm in diameter, and the NEMA-IQ study confirmed higher contrast recovery coefficients (CRC) for the smallest lesion (4.88 mm O). Initial human imaging validated clinical compatibility, showing enhanced resolution in high-count regions (e.g., brain) but increased noise in low-count regions (e.g., abdomen), highlighting areas for further refinement.
English
ISBN: 9798310388765Subjects--Topical Terms:
649834
Electrical engineering.
Subjects--Index Terms:
AWSM-PET system
Development of a Prototype AWSM-PET System for Augmented Whole-Body PET Imaging /
LDR
:04702nmm a22004333i 4500
001
2434831
005
20251001062535.5
006
m o d
007
cr|nu||||||||
008
261011s2025 miu||||||m |||||||eng d
020
$a
9798310388765
035
$a
(MiAaPQD)AAI31848708
035
$a
AAI31848708
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Chen, Yunlai,
$e
author.
$3
3824948
245
1 0
$a
Development of a Prototype AWSM-PET System for Augmented Whole-Body PET Imaging /
$c
Yunlai Chen.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2025
300
$a
1 electronic resource (152 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 86-10, Section: B.
500
$a
Advisors: Tai, Yuan-Chuan Committee members: O'Sullivan, Joseph A.; Laforest, Richard; Dehdashti, Farrokh; Jha, Abhinav K.
502
$b
Ph.D.
$c
Washington University in St. Louis
$d
2025.
520
$a
Positron Emission Tomography (PET) is a critical imaging modality for medical diagnostics, yet its accuracy is often limited by spatial resolution and sensitivity constraints. This dissertation presents the development of Augmented Whole-body Scan via Magnifying PET (AWSM-PET), a novel technique integrating high-resolution auxiliary detectors with a clinical PET scanner to enhance sensitivity and resolution while remaining fully compatible with standard clinical protocols. The study encompasses hardware development, image reconstruction methods, and performance evaluation through imaging studies, including human trials.High-resolution outsert panel detectors were designed, mounted on a mobile cart, and integrated with a Biograph Vision PET/CT scanner. Firmware and software modifications enabled simultaneous data acquisition under clinical protocols. The outsert detectors achieved an energy resolution of 11% full width at half maximum (FWHM) at 511 keV and a coincidence resolving time (CRT) of 183 ps FWHM. Sensitivity improved by up to 18.4%, depending on source location.A data-driven geometric alignment method was developed using point source measurements, achieving sub-millimeter precision without requiring special landmarks or repetitive measurements. This approach optimized the outsert detector positioning to minimize angular discrepancies in detected lines of response (LORs) via an iterative optimization method. Monte Carlo simulations confirmed that the deviation between the ground truth and estimated geometry remained well below 1 mm. Experimental validation demonstrated that point source images using the estimated geometry aligned well with those from the Biograph Vision scanner, with centroid deviations below 1 mm and angular deviations of line source images under 1 degree across the field of view.To support image reconstruction, a Maximum Likelihood Expectation Maximization (MLEM) listmode image reconstruction technique was developed for continuous-bed-motion (CBM) reconstruction in AWSM-PET. To balance reconstruction speed and accuracy, a single-ring approximation and grouped crystal approximation were introduced to accelerate sensitivity image calculation. Scatter and random corrections were implemented to achieve quantitative images, incorporating approximations to optimize computational efficiency. Additionally, a spatially variant point spread function (PSF) model was compared with a spatially invariant model. Rather than enhancing spatial resolution, the PSF model primarily contributes to improving contrast recovery and noise control.AWSM-PET was evaluated through NEMA-IQ, and mini-Derenzo phantoms, as well as human imaging studies. Compared to the Biograph Vision scanner, the mini-Derenzo phantom study demonstrated improved spatial resolution for spherical lesions ≤6 mm in diameter, and the NEMA-IQ study confirmed higher contrast recovery coefficients (CRC) for the smallest lesion (4.88 mm O). Initial human imaging validated clinical compatibility, showing enhanced resolution in high-count regions (e.g., brain) but increased noise in low-count regions (e.g., abdomen), highlighting areas for further refinement.
546
$a
English
590
$a
School code: 0252
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Medical imaging.
$3
3172799
653
$a
AWSM-PET system
653
$a
Positron Emission Tomography
653
$a
PET image reconstruction
653
$a
Virtual-Pinhole PET
653
$a
Coincidence resolving time
690
$a
0544
690
$a
0541
690
$a
0574
710
2
$a
Washington University in St. Louis.
$b
Interdisciplinary Programs.
$e
degree granting institution.
$3
3824949
720
1
$a
Tai, Yuan-Chuan
$e
degree supervisor.
773
0
$t
Dissertations Abstracts International
$g
86-10B.
790
$a
0252
791
$a
Ph.D.
792
$a
2025
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31848708
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9530526
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入