Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Development of Endovascular Devices ...
~
Oliver, Alexander Andrew,
Linked to FindBook
Google Book
Amazon
博客來
Development of Endovascular Devices Using Progressive Materials: In Vivo Evaluations of Bioresorbable and Magnetic Cell Capture Enabling Devices /
Record Type:
Electronic resources : Monograph/item
Title/Author:
Development of Endovascular Devices Using Progressive Materials: In Vivo Evaluations of Bioresorbable and Magnetic Cell Capture Enabling Devices // Alexander Andrew Oliver.
Author:
Oliver, Alexander Andrew,
Description:
1 electronic resource (331 pages)
Notes:
Source: Dissertations Abstracts International, Volume: 86-07, Section: B.
Contained By:
Dissertations Abstracts International86-07B.
Subject:
Biomedical engineering. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31769470
ISBN:
9798302181497
Development of Endovascular Devices Using Progressive Materials: In Vivo Evaluations of Bioresorbable and Magnetic Cell Capture Enabling Devices /
Oliver, Alexander Andrew,
Development of Endovascular Devices Using Progressive Materials: In Vivo Evaluations of Bioresorbable and Magnetic Cell Capture Enabling Devices /
Alexander Andrew Oliver. - 1 electronic resource (331 pages)
Source: Dissertations Abstracts International, Volume: 86-07, Section: B.
Cardiovascular disease is the leading cause of death in the US. These conditions commonly present as lesions of the blood vessels that inhibit their ability to deliver blood to downstream tissues. Endovascular treatment approaches have rapidly grown in clinical use and application. In this approach, vascular access is gained in a peripheral blood vessel and a catheter is navigated through the vasculature to the lesion under X-ray guidance. An endovascular device, such as a stent, valve, or coil, is deployed through the catheter to treat the lesion. Relative to open surgery, the endovascular approach generally reduces pain, recovery time, and risk of periprocedural complication.While endovascular devices have become a gold standard approach for treating common vascular pathologies, there are still several associated complications such as device induced thrombosis and stenosis. Endovascular devices are typically constructed from materials selected to optimize deployability and mechanical function. These materials are considered tolerable and advertised as inert in the blood vessel.This thesis explores the concept of constructing endovascular devices from materials selected with the primary objective of improving the biological response, without compromising deployability and mechanical function. In Part 1, bioresorbable flow diverters are investigated for the treatment of intracranial aneurysms. These devices aim to serve their transient function of healing the aneurysm prior to safely dissolving, mitigating complications associated with the permanent presence of conventional flow diverters. Devices were prototyped from multiple materials and their strength, flow diversion functionality, and MRI safety were demonstrated in benchtop experiments. Iron-based bioresorbable flow diverters were evaluated in the rabbit elastase induced aneurysm model. These experiments demonstrated the selected materials were biocompatible but degraded too rapidly to effectively treat the aneurysms.In Part 2, an approach to magnetically capture cells to the surface of endovascular devices to promote healing is investigated. Magnetic stent grafts were used to capture autologous blood outgrowth endothelial cells in a porcine carotid artery pseudoaneurysm model. Magnetic venous stents were used to capture autologous mesenchymal stem cells in a rabbit iliac vein model. Both approaches demonstrated evidence of magnetic cell capture and improved healing relative to non-magnetic control devices in vivo.
English
ISBN: 9798302181497Subjects--Topical Terms:
535387
Biomedical engineering.
Subjects--Index Terms:
Biodegradable
Development of Endovascular Devices Using Progressive Materials: In Vivo Evaluations of Bioresorbable and Magnetic Cell Capture Enabling Devices /
LDR
:04214nmm a22004693i 4500
001
2434789
005
20251001062525.5
006
m o d
007
cr|nu||||||||
008
261011s2025 miu||||||m |||||||eng d
020
$a
9798302181497
035
$a
(MiAaPQD)AAI31769470
035
$a
AAI31769470
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Oliver, Alexander Andrew,
$e
author.
$3
3824890
245
1 0
$a
Development of Endovascular Devices Using Progressive Materials: In Vivo Evaluations of Bioresorbable and Magnetic Cell Capture Enabling Devices /
$c
Alexander Andrew Oliver.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2025
300
$a
1 electronic resource (331 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 86-07, Section: B.
500
$a
Advisors: Kallmes, David F.; Dragomir-Daescu, Dan Committee members: Leng, Shuai; Kadirvel, Ramanathan; Guillory, Roger J.
502
$b
Ph.D.
$c
College of Medicine - Mayo Clinic
$d
2025.
520
$a
Cardiovascular disease is the leading cause of death in the US. These conditions commonly present as lesions of the blood vessels that inhibit their ability to deliver blood to downstream tissues. Endovascular treatment approaches have rapidly grown in clinical use and application. In this approach, vascular access is gained in a peripheral blood vessel and a catheter is navigated through the vasculature to the lesion under X-ray guidance. An endovascular device, such as a stent, valve, or coil, is deployed through the catheter to treat the lesion. Relative to open surgery, the endovascular approach generally reduces pain, recovery time, and risk of periprocedural complication.While endovascular devices have become a gold standard approach for treating common vascular pathologies, there are still several associated complications such as device induced thrombosis and stenosis. Endovascular devices are typically constructed from materials selected to optimize deployability and mechanical function. These materials are considered tolerable and advertised as inert in the blood vessel.This thesis explores the concept of constructing endovascular devices from materials selected with the primary objective of improving the biological response, without compromising deployability and mechanical function. In Part 1, bioresorbable flow diverters are investigated for the treatment of intracranial aneurysms. These devices aim to serve their transient function of healing the aneurysm prior to safely dissolving, mitigating complications associated with the permanent presence of conventional flow diverters. Devices were prototyped from multiple materials and their strength, flow diversion functionality, and MRI safety were demonstrated in benchtop experiments. Iron-based bioresorbable flow diverters were evaluated in the rabbit elastase induced aneurysm model. These experiments demonstrated the selected materials were biocompatible but degraded too rapidly to effectively treat the aneurysms.In Part 2, an approach to magnetically capture cells to the surface of endovascular devices to promote healing is investigated. Magnetic stent grafts were used to capture autologous blood outgrowth endothelial cells in a porcine carotid artery pseudoaneurysm model. Magnetic venous stents were used to capture autologous mesenchymal stem cells in a rabbit iliac vein model. Both approaches demonstrated evidence of magnetic cell capture and improved healing relative to non-magnetic control devices in vivo.
546
$a
English
590
$a
School code: 1542
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Pathology.
$3
643180
650
4
$a
Medical imaging.
$3
3172799
650
4
$a
Surgery.
$3
707153
653
$a
Biodegradable
653
$a
Bioresorbable flow diverters
653
$a
Endothelialization
653
$a
Endovascular devices
653
$a
Magnetic cell capture
653
$a
Magnetic stent grafts
690
$a
0541
690
$a
0576
690
$a
0574
690
$a
0571
710
2
$a
College of Medicine - Mayo Clinic.
$b
Biomedical Engineering.
$e
degree granting institution.
$3
3824891
720
1
$a
Kallmes, David F.
$e
degree supervisor.
720
1
$a
Dragomir-Daescu, Dan
$e
degree supervisor.
773
0
$t
Dissertations Abstracts International
$g
86-07B.
790
$a
1542
791
$a
Ph.D.
792
$a
2025
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31769470
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9530484
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login