Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Ultra-Fast Langmuir Probe Diagnostic...
~
Hickling, Christopher James,
Linked to FindBook
Google Book
Amazon
博客來
Ultra-Fast Langmuir Probe Diagnostic for Magnetised Plasma /
Record Type:
Electronic resources : Monograph/item
Title/Author:
Ultra-Fast Langmuir Probe Diagnostic for Magnetised Plasma // Christopher James Hickling.
Author:
Hickling, Christopher James,
Description:
1 electronic resource (146 pages)
Notes:
Source: Dissertations Abstracts International, Volume: 85-08, Section: B.
Contained By:
Dissertations Abstracts International85-08B.
Subject:
Receivers & amplifiers. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30832335
ISBN:
9798381557664
Ultra-Fast Langmuir Probe Diagnostic for Magnetised Plasma /
Hickling, Christopher James,
Ultra-Fast Langmuir Probe Diagnostic for Magnetised Plasma /
Christopher James Hickling. - 1 electronic resource (146 pages)
Source: Dissertations Abstracts International, Volume: 85-08, Section: B.
In order to better understand the processes behind nuclear fusion, high precision and reliable diagnostics are required. Traditionally, analogue diagnostics have been used, mostly due to cost and availability. Analogue electronics take up a large volume and often have to be completely redesigned when moving to different systems or making changes to their function. In recent decades, huge advancements in digital technology has made the use of digital systems more affordable and more robust. The Field Programmable Gate Array (FPGA) can provide a low-cost and modular solution to the analogue problem.This thesis will describe the designing, implementation and testing of a new diagnostic for future installation onto Mega Amp Spherical Tokamak - Upgrade (MASTU), the Ultra Fast Langmuir Probe (UFLP). The UFLP aims to solve the Langmuir equation in real time utilising only a single Langmuir probe configuration to return the electron temperature, ion saturation current and plasma floating potential. It achieves this via fast biasing and dynamic adjustment of the bias range to ensure samples are taken within the transition region. The design of such a system both in terms of FPGA design and electrical hardware will be described. To ensure properly functionality, real-world testing results in low temperature magnetron systems will be presented.
English
ISBN: 9798381557664Subjects--Topical Terms:
3559205
Receivers & amplifiers.
Ultra-Fast Langmuir Probe Diagnostic for Magnetised Plasma /
LDR
:02782nmm a22004453i 4500
001
2434055
005
20250905091334.5
006
m o d
007
cr|nu||||||||
008
261011s2023 miu||||||m |||||||eng d
020
$a
9798381557664
035
$a
(MiAaPQD)AAI30832335
035
$a
(MiAaPQD)Liverpool_3172867
035
$a
AAI30832335
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Hickling, Christopher James,
$e
author.
$3
3823908
245
1 0
$a
Ultra-Fast Langmuir Probe Diagnostic for Magnetised Plasma /
$c
Christopher James Hickling.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2023
300
$a
1 electronic resource (146 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 85-08, Section: B.
500
$a
Advisors: Bradley, James W.; Hall, Stephanie.
502
$b
Ph.D.
$c
The University of Liverpool (United Kingdom)
$d
2023.
520
$a
In order to better understand the processes behind nuclear fusion, high precision and reliable diagnostics are required. Traditionally, analogue diagnostics have been used, mostly due to cost and availability. Analogue electronics take up a large volume and often have to be completely redesigned when moving to different systems or making changes to their function. In recent decades, huge advancements in digital technology has made the use of digital systems more affordable and more robust. The Field Programmable Gate Array (FPGA) can provide a low-cost and modular solution to the analogue problem.This thesis will describe the designing, implementation and testing of a new diagnostic for future installation onto Mega Amp Spherical Tokamak - Upgrade (MASTU), the Ultra Fast Langmuir Probe (UFLP). The UFLP aims to solve the Langmuir equation in real time utilising only a single Langmuir probe configuration to return the electron temperature, ion saturation current and plasma floating potential. It achieves this via fast biasing and dynamic adjustment of the bias range to ensure samples are taken within the transition region. The design of such a system both in terms of FPGA design and electrical hardware will be described. To ensure properly functionality, real-world testing results in low temperature magnetron systems will be presented.
546
$a
English
590
$a
School code: 0722
650
4
$a
Receivers & amplifiers.
$3
3559205
650
4
$a
Design.
$3
518875
650
4
$a
Plasma.
$3
877619
650
4
$a
Power supply.
$3
3683627
650
4
$a
Energy.
$3
876794
650
4
$a
Electrons.
$3
516581
650
4
$a
Fusion.
$3
3380818
650
4
$a
Magnetic fields.
$3
660770
650
4
$a
Field programmable gate arrays.
$3
666370
650
4
$a
Atomic physics.
$3
3173870
650
4
$a
Computer engineering.
$3
621879
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Electromagnetics.
$3
3173223
650
4
$a
Physics.
$3
516296
690
$a
0389
690
$a
0791
690
$a
0748
690
$a
0464
690
$a
0544
690
$a
0607
690
$a
0605
710
2
$a
The University of Liverpool (United Kingdom).
$e
degree granting institution.
$3
3767499
720
1
$a
Bradley, James W.
$e
degree supervisor.
720
1
$a
Hall, Stephanie
$e
degree supervisor.
773
0
$t
Dissertations Abstracts International
$g
85-08B.
790
$a
0722
791
$a
Ph.D.
792
$a
2023
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30832335
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9529750
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login