Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Reduced Order Modeling for Vapor Com...
~
Ma, Jiacheng,
Linked to FindBook
Google Book
Amazon
博客來
Reduced Order Modeling for Vapor Compression Systems Via Proper Orthogonal Decomposition /
Record Type:
Electronic resources : Monograph/item
Title/Author:
Reduced Order Modeling for Vapor Compression Systems Via Proper Orthogonal Decomposition // Jiacheng Ma.
Author:
Ma, Jiacheng,
Description:
1 electronic resource (102 pages)
Notes:
Source: Masters Abstracts International, Volume: 84-12.
Contained By:
Masters Abstracts International84-12.
Subject:
Load. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30502790
ISBN:
9798379676681
Reduced Order Modeling for Vapor Compression Systems Via Proper Orthogonal Decomposition /
Ma, Jiacheng,
Reduced Order Modeling for Vapor Compression Systems Via Proper Orthogonal Decomposition /
Jiacheng Ma. - 1 electronic resource (102 pages)
Source: Masters Abstracts International, Volume: 84-12.
Dynamic modeling of Vapor Compression Cycles (VCC) is particularly important for designing and evaluating controls and fault detection and diagnosis (FDD) algorithms. As a result, transient modeling of VCCs has become an active area of research over the past two decades. Although a number of tools have been developed, the computational requirements for dynamic VCC simulations are still significant. A computationally efficient but accurate modeling approach is critically important to accelerate the design and assessment of control and FDD algorithms where a number of iterations with a variety of test input signals are required. Typically, the dynamics of compressors and expansion devices evolve on an order of magnitude faster than those of heat exchangers (HX) within VCC systems. As a result, most dynamic modeling efforts have focused on heat exchanger models. The switched moving boundary (SMB) method, which segments a heat exchanger depending on thermodynamic phase of the refrigerant, i.e. subcooled liquid, two-phase and superheated vapor, and moves control volumes as the length of each phase changes, can reduce the computation time compared with the finite volume (FV) method by solving fewer equations due to a smaller set of control volumes. Despite the computational benefit of the SMB, there is a well-known numerical issue associated with switching the model representations when a phase zone disappears or reappears inside of a heat exchanger. More importantly, the computational load is still challenging for many practical VCC systems. This thesis proposes an approach applying nonlinear model order reduction (MOR) methods to dynamic heat exchanger models to generate reduced order HX models, and then to couple them to quasi-static models of other VCC components to complete a reduced order VCC model. To enable the use of nonlinear model reduction techniques, a reformulated FV model is developed for matching the baseline MOR model structure, by using different pairs of thermodynamic states with some appropriate assumptions. Then a rigorous nonlinear model order reduction framework based on Proper Orthogonal Decomposition (POD) and the Discrete Empirical Interpolation Method (DEIM) is developed to generate reduced order HX models.The proposed reduced order modeling approach is implemented within a complete VCC model. Reduced order HX models are constructed for a centrifugal chiller teststand at Herrick Labs, Purdue University, and are integrated with quasi-static models of compressor and expansion valve to form the complete cycle. The reduced cycle model is simulated in the Modelica-based platform to predict load-change transients, and is compared with measurements. The validation results indicate that the reduced order model executes 200 times faster than real time with negligible prediction errors.
English
ISBN: 9798379676681Subjects--Topical Terms:
3562902
Load.
Reduced Order Modeling for Vapor Compression Systems Via Proper Orthogonal Decomposition /
LDR
:04110nmm a22003853i 4500
001
2433888
005
20250909080244.5
006
m o d
007
cr|nu||||||||
008
261011s2019 miu||||||m |||||||eng d
020
$a
9798379676681
035
$a
(MiAaPQD)AAI30502790
035
$a
(MiAaPQD)Purdue11312597
035
$a
AAI30502790
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Ma, Jiacheng,
$e
author.
$3
3823671
245
1 0
$a
Reduced Order Modeling for Vapor Compression Systems Via Proper Orthogonal Decomposition /
$c
Jiacheng Ma.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
1 electronic resource (102 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 84-12.
500
$a
Advisors: Braun, James E. Committee members: Jain, Neera.
502
$b
M.Sc.
$c
Purdue University
$d
2019.
520
$a
Dynamic modeling of Vapor Compression Cycles (VCC) is particularly important for designing and evaluating controls and fault detection and diagnosis (FDD) algorithms. As a result, transient modeling of VCCs has become an active area of research over the past two decades. Although a number of tools have been developed, the computational requirements for dynamic VCC simulations are still significant. A computationally efficient but accurate modeling approach is critically important to accelerate the design and assessment of control and FDD algorithms where a number of iterations with a variety of test input signals are required. Typically, the dynamics of compressors and expansion devices evolve on an order of magnitude faster than those of heat exchangers (HX) within VCC systems. As a result, most dynamic modeling efforts have focused on heat exchanger models. The switched moving boundary (SMB) method, which segments a heat exchanger depending on thermodynamic phase of the refrigerant, i.e. subcooled liquid, two-phase and superheated vapor, and moves control volumes as the length of each phase changes, can reduce the computation time compared with the finite volume (FV) method by solving fewer equations due to a smaller set of control volumes. Despite the computational benefit of the SMB, there is a well-known numerical issue associated with switching the model representations when a phase zone disappears or reappears inside of a heat exchanger. More importantly, the computational load is still challenging for many practical VCC systems. This thesis proposes an approach applying nonlinear model order reduction (MOR) methods to dynamic heat exchanger models to generate reduced order HX models, and then to couple them to quasi-static models of other VCC components to complete a reduced order VCC model. To enable the use of nonlinear model reduction techniques, a reformulated FV model is developed for matching the baseline MOR model structure, by using different pairs of thermodynamic states with some appropriate assumptions. Then a rigorous nonlinear model order reduction framework based on Proper Orthogonal Decomposition (POD) and the Discrete Empirical Interpolation Method (DEIM) is developed to generate reduced order HX models.The proposed reduced order modeling approach is implemented within a complete VCC model. Reduced order HX models are constructed for a centrifugal chiller teststand at Herrick Labs, Purdue University, and are integrated with quasi-static models of compressor and expansion valve to form the complete cycle. The reduced cycle model is simulated in the Modelica-based platform to predict load-change transients, and is compared with measurements. The validation results indicate that the reduced order model executes 200 times faster than real time with negligible prediction errors.
546
$a
English
590
$a
School code: 0183
650
4
$a
Load.
$3
3562902
650
4
$a
Heat transfer.
$3
3391367
650
4
$a
Behavior.
$3
532476
650
4
$a
Control algorithms.
$3
3560702
650
4
$a
Partial differential equations.
$3
2180177
650
4
$a
Heat exchangers.
$3
626398
650
4
$a
Decomposition.
$3
3561186
650
4
$a
HVAC.
$3
3555644
650
4
$a
Energy.
$3
876794
650
4
$a
Boundary conditions.
$3
3560411
650
4
$a
Mathematics.
$3
515831
650
4
$a
Thermodynamics.
$3
517304
690
$a
0791
690
$a
0405
690
$a
0348
710
2
$a
Purdue University.
$e
degree granting institution.
$3
3759105
720
1
$a
Braun, James E.
$e
degree supervisor.
773
0
$t
Masters Abstracts International
$g
84-12.
790
$a
0183
791
$a
M.Sc.
792
$a
2019
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30502790
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9529583
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login