語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Deep Learning Strategies for PET and...
~
Xie, Huidong,
FindBook
Google Book
Amazon
博客來
Deep Learning Strategies for PET and SPECT Image Enhancement /
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Deep Learning Strategies for PET and SPECT Image Enhancement // Huidong Xie.
作者:
Xie, Huidong,
面頁冊數:
1 electronic resource (314 pages)
附註:
Source: Dissertations Abstracts International, Volume: 86-12, Section: B.
Contained By:
Dissertations Abstracts International86-12B.
標題:
Biomedical engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31845806
ISBN:
9798286445004
Deep Learning Strategies for PET and SPECT Image Enhancement /
Xie, Huidong,
Deep Learning Strategies for PET and SPECT Image Enhancement /
Huidong Xie. - 1 electronic resource (314 pages)
Source: Dissertations Abstracts International, Volume: 86-12, Section: B.
Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT) are essential imaging modalities in nuclear medicine, providing critical diagnostic information for a wide range of medical applications, including oncology, cardiology, and neurology studies. However, the image quality of nuclear imaging could be negatively affected by various factors, including reduced radiation dose, limited spatial resolution, the partial volume effect, and the positron range effect. In this dissertation, a series of deep learning strategies are presented to address these challenges, with the aim of improving the safety, efficiency, and diagnostic accuracy of nuclear imaging.In PET imaging, we addressed the challenges related to 3D PET image denoising and positron range effect. In Chapter 2, we developed DDPET-3D, a dose-aware diffusion-based framework for 3D PET imaging, which was validated on a large-scale, multi-institutional PET dataset. This framework demonstrated superior performance compared to baseline methods, with nuclear medicine physicists judging the denoised images to be visually comparable to full-dose images, highlighting its clinical potential. Additional evaluations of DDPET-3D, including multi-modal PET-CT denoising and PET image enhancement within a radiation therapy system, are provided in Appendix B. In Chapter 3, we addressed the noise and positron range effects in dynamic 82Rb cardiac PET imaging through a self-supervised noise-aware dynamic denoising and positron range correction framework. This approach enabled robust dynamic image denoising and positron range correction without paired training data. The presented results demonstrated the potential of improved image quantification, particularly in myocardial blood flow (MBF) assessments and other key clinical metrics. In the Appendix A, we introduced another PET image denoising method, the Unified Noise-aware Network (UNN), which employed a noise-aware mechanism to adaptively weight sub-denoising networks based on varying noise levels, providing robust and generalizable results.In SPECT imaging, we introduced DiffSPECT-3D (Chapter 4), a diffusion-based framework for 3D cardiac SPECT image enhancement under various acquisition settings, including different low-dose and few-view settings. By enforcing projection/image data consistency and integrating anatomical priors, DiffSPECT-3D demonstrated superior generalizability across diverse acquisition settings without additional network re-training or fine-tuning. In Chapter 5, to mitigate the partial volume effect without the tedious manual segmentation steps, we proposed a segmentation-free partial volume correction method that improves quantitative precision while reducing radiation exposure to the patients by eliminating the need for additional contrast-enhanced CT or MRI scans. In Chapter 6, to further enhance image quality on stationary cardiac SPECT scanners, we developed a multi-angle reconstruction protocol to increase angular sampling. To preserve the stationary benefits of this scanner type, we introduced a deep-learning-based framework to synthesize multi-angle data from single-angle counterparts. In the Appendix D and Appendix E, we also explored image-domain and dual-domain transformer-based methods for few-view SPECT imaging. For all SPECT imaging projects, comprehensive validations using physical phantoms, animal studies, and human datasets were performed, demonstrating potential improvements in spatial resolution, diagnostic accuracy, and overall image quality.The deep learning strategies proposed in this dissertation collectively enhance PET and SPECT imaging by addressing critical challenges such as dose reduction, noise suppression, and image resolution enhancement. These innovations contribute to safer, faster, and more accurate imaging, with the potential to improve diagnostic performance and patient outcomes, and establish a strong foundation for future advancements in AI-driven medical imaging technologies.
English
ISBN: 9798286445004Subjects--Topical Terms:
535387
Biomedical engineering.
Subjects--Index Terms:
Deep learning
Deep Learning Strategies for PET and SPECT Image Enhancement /
LDR
:05506nmm a22004453i 4500
001
2433803
005
20250905091016.5
006
m o d
007
cr|nu||||||||
008
261011s2025 miu||||||m |||||||eng d
020
$a
9798286445004
035
$a
(MiAaPQD)AAI31845806
035
$a
AAI31845806
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Xie, Huidong,
$e
author.
$3
3823559
245
1 0
$a
Deep Learning Strategies for PET and SPECT Image Enhancement /
$c
Huidong Xie.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2025
300
$a
1 electronic resource (314 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 86-12, Section: B.
500
$a
Advisors: Liu, Chi Committee members: Sinusas, Albert; Carson, Richard; Papademetris, Xenophon.
502
$b
Ph.D.
$c
Yale University
$d
2025.
520
$a
Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT) are essential imaging modalities in nuclear medicine, providing critical diagnostic information for a wide range of medical applications, including oncology, cardiology, and neurology studies. However, the image quality of nuclear imaging could be negatively affected by various factors, including reduced radiation dose, limited spatial resolution, the partial volume effect, and the positron range effect. In this dissertation, a series of deep learning strategies are presented to address these challenges, with the aim of improving the safety, efficiency, and diagnostic accuracy of nuclear imaging.In PET imaging, we addressed the challenges related to 3D PET image denoising and positron range effect. In Chapter 2, we developed DDPET-3D, a dose-aware diffusion-based framework for 3D PET imaging, which was validated on a large-scale, multi-institutional PET dataset. This framework demonstrated superior performance compared to baseline methods, with nuclear medicine physicists judging the denoised images to be visually comparable to full-dose images, highlighting its clinical potential. Additional evaluations of DDPET-3D, including multi-modal PET-CT denoising and PET image enhancement within a radiation therapy system, are provided in Appendix B. In Chapter 3, we addressed the noise and positron range effects in dynamic 82Rb cardiac PET imaging through a self-supervised noise-aware dynamic denoising and positron range correction framework. This approach enabled robust dynamic image denoising and positron range correction without paired training data. The presented results demonstrated the potential of improved image quantification, particularly in myocardial blood flow (MBF) assessments and other key clinical metrics. In the Appendix A, we introduced another PET image denoising method, the Unified Noise-aware Network (UNN), which employed a noise-aware mechanism to adaptively weight sub-denoising networks based on varying noise levels, providing robust and generalizable results.In SPECT imaging, we introduced DiffSPECT-3D (Chapter 4), a diffusion-based framework for 3D cardiac SPECT image enhancement under various acquisition settings, including different low-dose and few-view settings. By enforcing projection/image data consistency and integrating anatomical priors, DiffSPECT-3D demonstrated superior generalizability across diverse acquisition settings without additional network re-training or fine-tuning. In Chapter 5, to mitigate the partial volume effect without the tedious manual segmentation steps, we proposed a segmentation-free partial volume correction method that improves quantitative precision while reducing radiation exposure to the patients by eliminating the need for additional contrast-enhanced CT or MRI scans. In Chapter 6, to further enhance image quality on stationary cardiac SPECT scanners, we developed a multi-angle reconstruction protocol to increase angular sampling. To preserve the stationary benefits of this scanner type, we introduced a deep-learning-based framework to synthesize multi-angle data from single-angle counterparts. In the Appendix D and Appendix E, we also explored image-domain and dual-domain transformer-based methods for few-view SPECT imaging. For all SPECT imaging projects, comprehensive validations using physical phantoms, animal studies, and human datasets were performed, demonstrating potential improvements in spatial resolution, diagnostic accuracy, and overall image quality.The deep learning strategies proposed in this dissertation collectively enhance PET and SPECT imaging by addressing critical challenges such as dose reduction, noise suppression, and image resolution enhancement. These innovations contribute to safer, faster, and more accurate imaging, with the potential to improve diagnostic performance and patient outcomes, and establish a strong foundation for future advancements in AI-driven medical imaging technologies.
546
$a
English
590
$a
School code: 0265
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Medical imaging.
$3
3172799
650
4
$a
Medicine.
$3
641104
650
4
$a
Nuclear chemistry.
$3
643077
653
$a
Deep learning
653
$a
Nuclear medicine
653
$a
Positron Emission Tomography
653
$a
Single Photon Emission Computed Tomography
653
$a
Myocardial blood flow
690
$a
0541
690
$a
0574
690
$a
0564
690
$a
0738
710
2
$a
Yale University.
$b
Biomedical Engineering.
$e
degree granting institution.
$3
3818985
720
1
$a
Liu, Chi
$e
degree supervisor.
773
0
$t
Dissertations Abstracts International
$g
86-12B.
790
$a
0265
791
$a
Ph.D.
792
$a
2025
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31845806
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9529498
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入