CFD Modelling of Axial Fans for Ther...
~
Franzke, Randi,
Linked to FindBook
Google Book
Amazon
博客來
CFD Modelling of Axial Fans for Thermal Management Applications /
Record Type:
Electronic resources : Monograph/item
Title/Author:
CFD Modelling of Axial Fans for Thermal Management Applications // Randi Franzke.
Author:
Franzke, Randi,
Description:
1 electronic resource (67 pages)
Notes:
Source: Masters Abstracts International, Volume: 81-03.
Contained By:
Masters Abstracts International81-03.
Subject:
Thermodynamics. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=27555776
ISBN:
9781085754422
CFD Modelling of Axial Fans for Thermal Management Applications /
Franzke, Randi,
CFD Modelling of Axial Fans for Thermal Management Applications /
Randi Franzke. - 1 electronic resource (67 pages)
Source: Masters Abstracts International, Volume: 81-03.
Reducing CO2 emissions is one of the key challenges in today's automotive industry. Different strategies to achieve this goal are, for example, to electrify the powertrain and to reduce the aerodynamic drag by reducing the amount of cooling air through the underhood. In order not to sacrifice the cooling performance, a better understanding of the air flow through the underhood compartment is necessary. Computational Fluid Dynamics (CFD) is an important tool for the investigation of the underhood flow, since it gives the possibility to look at the flow field even in areas where measurement equipment cannot reach. This work focusses on the simulation of the main driving factor of underhood flow: the axial cooling fan. In CFD multiple methods of varying complexity are available to simulate the fan rotation. The more computational expensive approach, called the Rigid Body Motion (RBM), physically resolves the rotation, while the less expensive approach, called the Multiple Reference Frame (MRF), rotates the air in proximity to a stationary rotor around the blades. In the first study presented in this thesis, the flow field downstream of an axial fan is investigated for these two methods and in addition, a third hybrid approach is also evaluated. The results are compared to experimental data, which were obtained in the Volvo Cars Model-scale Wind Tunnel by using Laser Doppler Anemometry. In the second study, the interaction between the MRF approach and different upstream and downstream conditions were investigated. For this study, a temperature variation upstream of the rotor is introduced, as well as different geometric obstacles up- and downstream.As a result of the presented investigations it could be confirmed that the RBM approach gives the best representation of the flow field downstream of the fan. The MRF on the other hand showed severe limitations that the users need to be aware of. Especially the rotation of an upstream temperature source, that was found in Paper II, can lead to misleading results of component temperatures. However, when the temperature field is uniformly distributed or of minor importance, the MRF is still the most feasible approach for large applications.
English
ISBN: 9781085754422Subjects--Topical Terms:
517304
Thermodynamics.
Subjects--Index Terms:
Axial cooling fans
CFD Modelling of Axial Fans for Thermal Management Applications /
LDR
:03415nmm a22003853i 4500
001
2432503
005
20250718090818.5
006
m o d
007
cr|nu||||||||
008
261011s2019 miu||||||m |||||||eng d
020
$a
9781085754422
035
$a
(MiAaPQD)AAI27555776
035
$a
(MiAaPQD)Chalmers_SE510470
035
$a
AAI27555776
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Franzke, Randi,
$e
author.
$3
3821751
245
1 0
$a
CFD Modelling of Axial Fans for Thermal Management Applications /
$c
Randi Franzke.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
1 electronic resource (67 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 81-03.
502
$b
Licentiate
$c
Chalmers Tekniska Hogskola (Sweden)
$d
2019.
520
$a
Reducing CO2 emissions is one of the key challenges in today's automotive industry. Different strategies to achieve this goal are, for example, to electrify the powertrain and to reduce the aerodynamic drag by reducing the amount of cooling air through the underhood. In order not to sacrifice the cooling performance, a better understanding of the air flow through the underhood compartment is necessary. Computational Fluid Dynamics (CFD) is an important tool for the investigation of the underhood flow, since it gives the possibility to look at the flow field even in areas where measurement equipment cannot reach. This work focusses on the simulation of the main driving factor of underhood flow: the axial cooling fan. In CFD multiple methods of varying complexity are available to simulate the fan rotation. The more computational expensive approach, called the Rigid Body Motion (RBM), physically resolves the rotation, while the less expensive approach, called the Multiple Reference Frame (MRF), rotates the air in proximity to a stationary rotor around the blades. In the first study presented in this thesis, the flow field downstream of an axial fan is investigated for these two methods and in addition, a third hybrid approach is also evaluated. The results are compared to experimental data, which were obtained in the Volvo Cars Model-scale Wind Tunnel by using Laser Doppler Anemometry. In the second study, the interaction between the MRF approach and different upstream and downstream conditions were investigated. For this study, a temperature variation upstream of the rotor is introduced, as well as different geometric obstacles up- and downstream.As a result of the presented investigations it could be confirmed that the RBM approach gives the best representation of the flow field downstream of the fan. The MRF on the other hand showed severe limitations that the users need to be aware of. Especially the rotation of an upstream temperature source, that was found in Paper II, can lead to misleading results of component temperatures. However, when the temperature field is uniformly distributed or of minor importance, the MRF is still the most feasible approach for large applications.
546
$a
English
590
$a
School code: 0419
650
4
$a
Thermodynamics.
$3
517304
650
4
$a
Automotive engineering.
$3
2181195
650
4
$a
Fluid mechanics.
$3
528155
650
4
$a
Mechanical engineering.
$3
649730
653
$a
Axial cooling fans
690
$a
0548
690
$a
0204
690
$a
0348
690
$a
0540
710
2
$a
Chalmers Tekniska Hogskola (Sweden).
$e
degree granting institution.
$3
3770588
773
0
$t
Masters Abstracts International
$g
81-03.
790
$a
0419
791
$a
Licentiate
792
$a
2019
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=27555776
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9528198
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login