Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Digital Signal Processing Techniques...
~
Anderson, Damon,
Linked to FindBook
Google Book
Amazon
博客來
Digital Signal Processing Techniques and ASIC Development for 3D CdZnTe Gamma-Ray Detectors /
Record Type:
Electronic resources : Monograph/item
Title/Author:
Digital Signal Processing Techniques and ASIC Development for 3D CdZnTe Gamma-Ray Detectors // Damon Anderson.
Author:
Anderson, Damon,
Description:
1 electronic resource (122 pages)
Notes:
Source: Dissertations Abstracts International, Volume: 86-07, Section: B.
Contained By:
Dissertations Abstracts International86-07B.
Subject:
Engineering. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31871441
ISBN:
9798346892021
Digital Signal Processing Techniques and ASIC Development for 3D CdZnTe Gamma-Ray Detectors /
Anderson, Damon,
Digital Signal Processing Techniques and ASIC Development for 3D CdZnTe Gamma-Ray Detectors /
Damon Anderson. - 1 electronic resource (122 pages)
Source: Dissertations Abstracts International, Volume: 86-07, Section: B.
Over the last 30 years, CdZnTe (CZT) radiation detectors have been developed into one competitive room-temperature option for gamma-ray spectroscopy and imaging. Electronic readout from triggered anode pixels and a single planar cathode enables the position of each interaction to be located with a resolution of < 500 μm in all three dimensions at 662 keV. Using the 3D position of interaction as a basis for energy calibration, energy resolution of < 1% for all events, and best energy resolutions of < 0.35% resolution for single-pixel events at 662 keV have been demonstrated. The unique capabilities of 3D-CZT lend to its use in medical applications such as positron emission tomography (PET). One component of this work is the evaluation of the timing resolution achievable by 3D-CZT, a critical parameter for coincidence systems employed in PET imaging. Prior studies achieved timing resolutions of <10 ns using 1 cm thick CZT with GHz sampling systems and waveform fitting techniques. In this study, hand-held systems employing 1.5 cm thick CZT, sampling frequencies up to 80 MHz, and linear-fit-based digital signals processing (DSP) techniques yield a best timing resolution of 36.3 ns. Simulations based on the system response waveforms and measured system noise indicate that the measured timing resolution is in agreement with the limits imposed by cathode noise. Towards further optimization of timing resolution in 3D-CZT coincidence systems, investigations on the correlation between cathode noise and detector thickness, area, and applied bias are recommended.System compactness is at a premium for any fields requiring portability such as military, space, and reactor inspection. For current 3D-CZT electronic readout, a CPU is required to perform complex filtering operations on the anode and cathode waveforms. Discrete analog-to-digital converters (ADCs), and a field programmable gate array (FPGA) are required to read out waveforms from the front-end electronics. To significantly reduce power consumption and area requirements, an application specific integrated circuit (ASIC) is proposed which brings the ADC, data acquisition (DAQ), and DSP all onto one piece of silicon. Four revisions of the DSP-DAQ-ADC ASIC have been taped out over the last four years on the TSMC 65nm MS RF GP technology. The 4th iteration of the chip is the first back-end digital ASIC used with 3D-CZT to demonstrate a calibrated energy spectrum, achieving a resolution of 0.6% for single-pixel events at 662 keV. With a die area of 9 mm2 and a total power consumption of 35 mW, the DSP-DAQ-ADCv4 ASIC is a step towards the next generation of low power, hand-held 3D-CZT systems.
English
ISBN: 9798346892021Subjects--Topical Terms:
586835
Engineering.
Subjects--Index Terms:
Radiation detection
Digital Signal Processing Techniques and ASIC Development for 3D CdZnTe Gamma-Ray Detectors /
LDR
:04239nmm a22004573i 4500
001
2432489
005
20250707081513.5
006
m o d
007
cr|nu||||||||
008
261011s2024 miu||||||m |||||||eng d
020
$a
9798346892021
035
$a
(MiAaPQD)AAI31871441
035
$a
(MiAaPQD)umichrackham005900
035
$a
AAI31871441
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Anderson, Damon,
$e
author.
$3
3821725
245
1 0
$a
Digital Signal Processing Techniques and ASIC Development for 3D CdZnTe Gamma-Ray Detectors /
$c
Damon Anderson.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2024
300
$a
1 electronic resource (122 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 86-07, Section: B.
500
$a
Advisors: He, Zhong Committee members: Flynn, Michael; Jovanovic, Igor; Zhu, Yuefeng.
502
$b
Ph.D.
$c
University of Michigan
$d
2024.
520
$a
Over the last 30 years, CdZnTe (CZT) radiation detectors have been developed into one competitive room-temperature option for gamma-ray spectroscopy and imaging. Electronic readout from triggered anode pixels and a single planar cathode enables the position of each interaction to be located with a resolution of < 500 μm in all three dimensions at 662 keV. Using the 3D position of interaction as a basis for energy calibration, energy resolution of < 1% for all events, and best energy resolutions of < 0.35% resolution for single-pixel events at 662 keV have been demonstrated. The unique capabilities of 3D-CZT lend to its use in medical applications such as positron emission tomography (PET). One component of this work is the evaluation of the timing resolution achievable by 3D-CZT, a critical parameter for coincidence systems employed in PET imaging. Prior studies achieved timing resolutions of <10 ns using 1 cm thick CZT with GHz sampling systems and waveform fitting techniques. In this study, hand-held systems employing 1.5 cm thick CZT, sampling frequencies up to 80 MHz, and linear-fit-based digital signals processing (DSP) techniques yield a best timing resolution of 36.3 ns. Simulations based on the system response waveforms and measured system noise indicate that the measured timing resolution is in agreement with the limits imposed by cathode noise. Towards further optimization of timing resolution in 3D-CZT coincidence systems, investigations on the correlation between cathode noise and detector thickness, area, and applied bias are recommended.System compactness is at a premium for any fields requiring portability such as military, space, and reactor inspection. For current 3D-CZT electronic readout, a CPU is required to perform complex filtering operations on the anode and cathode waveforms. Discrete analog-to-digital converters (ADCs), and a field programmable gate array (FPGA) are required to read out waveforms from the front-end electronics. To significantly reduce power consumption and area requirements, an application specific integrated circuit (ASIC) is proposed which brings the ADC, data acquisition (DAQ), and DSP all onto one piece of silicon. Four revisions of the DSP-DAQ-ADC ASIC have been taped out over the last four years on the TSMC 65nm MS RF GP technology. The 4th iteration of the chip is the first back-end digital ASIC used with 3D-CZT to demonstrate a calibrated energy spectrum, achieving a resolution of 0.6% for single-pixel events at 662 keV. With a die area of 9 mm2 and a total power consumption of 35 mW, the DSP-DAQ-ADCv4 ASIC is a step towards the next generation of low power, hand-held 3D-CZT systems.
546
$a
English
590
$a
School code: 0127
650
4
$a
Engineering.
$3
586835
650
4
$a
Nuclear engineering.
$3
595435
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Physics.
$3
516296
653
$a
Radiation detection
653
$a
Semiconductor detectors
653
$a
Digital signals processing
653
$a
Positron emission tomography
653
$a
Field programmable gate array
690
$a
0537
690
$a
0552
690
$a
0544
690
$a
0605
710
2
$a
University of Michigan.
$b
Nuclear Engineering & Radiological Sciences.
$e
degree granting institution.
$3
3821726
720
1
$a
He, Zhong
$e
degree supervisor.
773
0
$t
Dissertations Abstracts International
$g
86-07B.
790
$a
0127
791
$a
Ph.D.
792
$a
2024
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31871441
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9528184
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login