Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Functional and Spatial Statistical M...
~
Wooten, Zachary T.,
Linked to FindBook
Google Book
Amazon
博客來
Functional and Spatial Statistical Methods With Applications in Radiotherapy Imaging /
Record Type:
Electronic resources : Monograph/item
Title/Author:
Functional and Spatial Statistical Methods With Applications in Radiotherapy Imaging // Zachary T Wooten.
Author:
Wooten, Zachary T.,
Description:
1 electronic resource (139 pages)
Notes:
Source: Dissertations Abstracts International, Volume: 86-02, Section: B.
Contained By:
Dissertations Abstracts International86-02B.
Subject:
Statistics. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31533132
ISBN:
9798383419502
Functional and Spatial Statistical Methods With Applications in Radiotherapy Imaging /
Wooten, Zachary T.,
Functional and Spatial Statistical Methods With Applications in Radiotherapy Imaging /
Zachary T Wooten. - 1 electronic resource (139 pages)
Source: Dissertations Abstracts International, Volume: 86-02, Section: B.
In this thesis, we propose functional and spatial statistical methods for the purpose of improving radiation therapy treatments and optimizing patient outcomes. Medical imaging is crucial for the diagnosis and treatment of a wide range of diseases, and deep learning models have increasingly been used for contouring medical images. However, ensuring the accuracy and safety of computer-generated contours is essential, particularly for radiation treatment planning. This thesis addresses the need to quantify the quality of these contours and to account for uncertainty in the delivered dose when predicting radiotherapy toxicities.In the first project, we introduce an innovative method for the quality assurance of autocontours, computer-generated contours, in medical imaging using shape statistics. This approach is distinct from the prevalent use of models that rely on image-specific features and leverages the geometric properties of the contour itself, offering broad applicability across various imaging technologies and medical institutions. By focusing on shape features that are invariant to the imaging modality, we present a solution that significantly advances medical imaging quality assurance, enabling more accurate and safe radiation treatment plans.Building on this, in the second project, we present a novel Bayesian additive regression trees model specifically designed for functional data that addresses the challenge of location-specific errors within treatment plans. This model, a novel approach in the field, not only identifies clinically unacceptable contours but also pinpoints the precise location of errors, providing clinicians with actionable insights for plan correction. This capability represents a substantial improvement over existing methods, which either lack specificity in error localization or depend heavily on imaging features that may vary across imaging modalities and medical institutions.In the third project, we expand the scope of treatment planning quality assurance to include spatial and measurement error models for lung radiation treatment planning, specifically focusing on the voxel-wise prediction of pneumonitis, a severe inflammation of lung tissue, as a negative consequence of radiation treatment. By incorporating spatial random effects and addressing measurement errors in radiation dose delivery, we offer a novel methodology for radiation treatment planning that provides deeper insights into the factors influencing treatment success and patient safety. This approach addresses the limitations of current methods of voxel-wise disease prediction that overlook spatial information and measurement inaccuracies, providing a more accurate assessment of negative outcomes such as the development of pneumonitis.All together, these projects bridge significant gaps in radiation therapy research, from enhancing the interpretability and effectiveness of autocontour quality assurance to incorporating spatial and measurement error considerations in treatment planning. This work not only contributes valuable tools and insights to the field of radiation therapy but also sets the stage for ongoing advancements in medical imaging and treatment optimization.
English
ISBN: 9798383419502Subjects--Topical Terms:
517247
Statistics.
Subjects--Index Terms:
Functional data analysis
Functional and Spatial Statistical Methods With Applications in Radiotherapy Imaging /
LDR
:04754nmm a22004453i 4500
001
2430801
005
20250603111619.5
006
m o d
007
cr|nu||||||||
008
261011s2024 miu||||||m |||||||eng d
020
$a
9798383419502
035
$a
(MiAaPQD)AAI31533132
035
$a
(MiAaPQD)0187rice5020Wooten
035
$a
AAI31533132
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Wooten, Zachary T.,
$e
author.
$3
3819305
245
1 0
$a
Functional and Spatial Statistical Methods With Applications in Radiotherapy Imaging /
$c
Zachary T Wooten.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2024
300
$a
1 electronic resource (139 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 86-02, Section: B.
500
$a
Advisors: Peterson, Christine; Kimmel, Marek Committee members: Kowal, Daniel; Treangen, Todd.
502
$b
Ph.D.
$c
Rice University
$d
2024.
520
$a
In this thesis, we propose functional and spatial statistical methods for the purpose of improving radiation therapy treatments and optimizing patient outcomes. Medical imaging is crucial for the diagnosis and treatment of a wide range of diseases, and deep learning models have increasingly been used for contouring medical images. However, ensuring the accuracy and safety of computer-generated contours is essential, particularly for radiation treatment planning. This thesis addresses the need to quantify the quality of these contours and to account for uncertainty in the delivered dose when predicting radiotherapy toxicities.In the first project, we introduce an innovative method for the quality assurance of autocontours, computer-generated contours, in medical imaging using shape statistics. This approach is distinct from the prevalent use of models that rely on image-specific features and leverages the geometric properties of the contour itself, offering broad applicability across various imaging technologies and medical institutions. By focusing on shape features that are invariant to the imaging modality, we present a solution that significantly advances medical imaging quality assurance, enabling more accurate and safe radiation treatment plans.Building on this, in the second project, we present a novel Bayesian additive regression trees model specifically designed for functional data that addresses the challenge of location-specific errors within treatment plans. This model, a novel approach in the field, not only identifies clinically unacceptable contours but also pinpoints the precise location of errors, providing clinicians with actionable insights for plan correction. This capability represents a substantial improvement over existing methods, which either lack specificity in error localization or depend heavily on imaging features that may vary across imaging modalities and medical institutions.In the third project, we expand the scope of treatment planning quality assurance to include spatial and measurement error models for lung radiation treatment planning, specifically focusing on the voxel-wise prediction of pneumonitis, a severe inflammation of lung tissue, as a negative consequence of radiation treatment. By incorporating spatial random effects and addressing measurement errors in radiation dose delivery, we offer a novel methodology for radiation treatment planning that provides deeper insights into the factors influencing treatment success and patient safety. This approach addresses the limitations of current methods of voxel-wise disease prediction that overlook spatial information and measurement inaccuracies, providing a more accurate assessment of negative outcomes such as the development of pneumonitis.All together, these projects bridge significant gaps in radiation therapy research, from enhancing the interpretability and effectiveness of autocontour quality assurance to incorporating spatial and measurement error considerations in treatment planning. This work not only contributes valuable tools and insights to the field of radiation therapy but also sets the stage for ongoing advancements in medical imaging and treatment optimization.
546
$a
English
590
$a
School code: 0187
650
4
$a
Statistics.
$3
517247
650
4
$a
Biostatistics.
$3
1002712
650
4
$a
Medical imaging.
$3
3172799
653
$a
Functional data analysis
653
$a
Shape statistics
653
$a
Radiation treatment planning
653
$a
Machine learning
690
$a
0463
690
$a
0574
690
$a
0308
710
2
$a
Rice University.
$b
Statistics.
$e
degree granting institution.
$3
3816467
720
1
$a
Peterson, Christine
$e
degree supervisor.
720
1
$a
Kimmel, Marek
$e
degree supervisor.
773
0
$t
Dissertations Abstracts International
$g
86-02B.
790
$a
0187
791
$a
Ph.D.
792
$a
2024
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31533132
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9526496
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login