Design and in situ testing of a piezometer system to measure earthquake -induced pore -pressure changes /
Record Type:
Electronic resources : Monograph/item
Title/Author:
Design and in situ testing of a piezometer system to measure earthquake -induced pore -pressure changes // Robert Farrell.
Author:
Farrell, Robert,
Description:
1 electronic resource (269 pages)
Notes:
Source: Dissertations Abstracts International, Volume: 65-02, Section: B.
Contained By:
Dissertations Abstracts International65-02B.
Subject:
Civil engineering. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3083728
ISBN:
9780496315352
Design and in situ testing of a piezometer system to measure earthquake -induced pore -pressure changes /
Farrell, Robert,
Design and in situ testing of a piezometer system to measure earthquake -induced pore -pressure changes /
Robert Farrell. - 1 electronic resource (269 pages)
Source: Dissertations Abstracts International, Volume: 65-02, Section: B.
Pore pressure changes have been measured in fine sand deposits that are known to have liquefied during earthquakes. Some of the measured signals have not been similar to what was expected during earthquake-induced liquefaction. Using artificially generated signals, several investigators have attempted to determine if existing piezometer fields designed to measure earthquake induced pore pressure changes are operating correctly. The signals generated during one investigation were not similar to those expected from an earthquake. In another investigation, while the generated signals were similar to ones expected from an earthquake, the results were not reproducible; the generated signals damaged the aquifer being tested and damaged or destroyed some piezometers being tested. This thesis describes the design and field-testing of a piezometer system that allows in situ testing of the screens on the piezometer, and in situ calibration of the transducer. An intergral part of this system is a signal generating system that generates a signal with frequencies similar to those expected from an earthquake. The generated signal has been detected in piezometers at least 20 feet from the source and at depths of at least 15 feet deeper than the source. The signal has been demonstrated to be reproducible through time with no measurable damage to the aquifer or the piezometers. It has been possible to investigate the ability of an existing piezometer field to detect earthquake-like signals and to demonstrate changes over time of some piezometers in their ability to detect earthquake-like signals. A detailed procedure for installing a piezometer array for liquefaction studies is presented.
English
ISBN: 9780496315352Subjects--Topical Terms:
860360
Civil engineering.
Subjects--Index Terms:
Earthquake-induced
Design and in situ testing of a piezometer system to measure earthquake -induced pore -pressure changes /
LDR
:03151nmm a22004453i 4500
001
2430634
005
20250527055720.5
006
m o d
007
cr|nu||||||||
008
261011s2003 miu||||||m |||||||eng d
020
$a
9780496315352
035
$a
(MiAaPQD)AAI3083728
035
$a
AAI3083728
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Farrell, Robert,
$e
author.
$3
3819052
245
1 0
$a
Design and in situ testing of a piezometer system to measure earthquake -induced pore -pressure changes /
$c
Robert Farrell.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2003
300
$a
1 electronic resource (269 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 65-02, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisors: Alba, Pedro A. de.
502
$b
Ph.D.
$c
University of New Hampshire
$d
2003.
520
$a
Pore pressure changes have been measured in fine sand deposits that are known to have liquefied during earthquakes. Some of the measured signals have not been similar to what was expected during earthquake-induced liquefaction. Using artificially generated signals, several investigators have attempted to determine if existing piezometer fields designed to measure earthquake induced pore pressure changes are operating correctly. The signals generated during one investigation were not similar to those expected from an earthquake. In another investigation, while the generated signals were similar to ones expected from an earthquake, the results were not reproducible; the generated signals damaged the aquifer being tested and damaged or destroyed some piezometers being tested. This thesis describes the design and field-testing of a piezometer system that allows in situ testing of the screens on the piezometer, and in situ calibration of the transducer. An intergral part of this system is a signal generating system that generates a signal with frequencies similar to those expected from an earthquake. The generated signal has been detected in piezometers at least 20 feet from the source and at depths of at least 15 feet deeper than the source. The signal has been demonstrated to be reproducible through time with no measurable damage to the aquifer or the piezometers. It has been possible to investigate the ability of an existing piezometer field to detect earthquake-like signals and to demonstrate changes over time of some piezometers in their ability to detect earthquake-like signals. A detailed procedure for installing a piezometer array for liquefaction studies is presented.
546
$a
English
590
$a
School code: 0141
650
4
$a
Civil engineering.
$3
860360
650
4
$a
Geotechnology.
$3
1018558
650
4
$a
Geology.
$3
516570
653
$a
Earthquake-induced
653
$a
In situ testing
653
$a
Liquefaction
653
$a
Piezometer
653
$a
Pore-pressure
690
$a
0543
690
$a
0428
690
$a
0372
710
2
$a
University of New Hampshire.
$e
degree granting institution.
$3
3819053
720
1
$a
Alba, Pedro A. de
$e
degree supervisor.
773
0
$t
Dissertations Abstracts International
$g
65-02B.
790
$a
0141
791
$a
Ph.D.
792
$a
2003
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3083728
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9526329
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login