Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Graphene-Conductive Ink Coated Laser...
~
Ghosh, Dipannita,
Linked to FindBook
Google Book
Amazon
博客來
Graphene-Conductive Ink Coated Laser Engraved Kapton Electrochemical Biosensor for the Detection of Dopamine and Immune Sensing /
Record Type:
Electronic resources : Monograph/item
Title/Author:
Graphene-Conductive Ink Coated Laser Engraved Kapton Electrochemical Biosensor for the Detection of Dopamine and Immune Sensing // Dipannita Ghosh.
Author:
Ghosh, Dipannita,
Description:
1 electronic resource (79 pages)
Notes:
Source: Masters Abstracts International, Volume: 85-01.
Contained By:
Masters Abstracts International85-01.
Subject:
Electrical engineering. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30310204
ISBN:
9798379951146
Graphene-Conductive Ink Coated Laser Engraved Kapton Electrochemical Biosensor for the Detection of Dopamine and Immune Sensing /
Ghosh, Dipannita,
Graphene-Conductive Ink Coated Laser Engraved Kapton Electrochemical Biosensor for the Detection of Dopamine and Immune Sensing /
Dipannita Ghosh. - 1 electronic resource (79 pages)
Source: Masters Abstracts International, Volume: 85-01.
Novel and flexible disposable laser-engraved Kapton (LEK) electrodes modified with graphene conductive inks have been developed for dopamine and Interleukin-6 (IL-6) detection. The LEK sensors exhibit high reproducibility (RSD=0.76%, N=5) and stability (RSD=4.39%, N=15)after multiple bendings, and thus make the sensors ideal for wearable and stretchable bioelectronics applications. We have developed graphene conductive ink- PEDOT:PSS (G-PEDOT:PSS) and polyaniline (G-PANI) based electrode coatings for working electrode modification to improve the sensitivity (41.41 times higher for screen printed electrode with G-PEDPT:PSS ink modification),and limit of detection (LOD) . We have further compared the performance of the fabricated electrodes with commercially available screen-printed electrodes (SPE), screen-printed electrodes modified with G-PEDOT:PSS (SPE/G-PEDOT:PSS) and G-PANI (SPE/G-PANI). SPE/G-PANI has a lower LOD of 0.632 μM, compared to SPE/G-PEDOT:PSS (0.867 μM) and SPE/G-PANI(1.974 μM). The lowest LOD of the LEK/G-PANI sensor (0.4084 μM, S/N=3) suggests that it can be a great alternative to measure dopamine levels in a physiological medium. Additionally, LEK/G-PANI electrode has excellent LOD (2.6234 pg/mL) to detect IL-6.GRAPHENE-CONDUCTIVE INK COATED LASER ENGRAVED KAPTONELECTROCHEMICAL BIOSENSOR FOR THE DETECTION OF DOPAMINE AND IMMUNESENSING.
English
ISBN: 9798379951146Subjects--Topical Terms:
649834
Electrical engineering.
Subjects--Index Terms:
Biosensors
Graphene-Conductive Ink Coated Laser Engraved Kapton Electrochemical Biosensor for the Detection of Dopamine and Immune Sensing /
LDR
:02804nmm a22004213i 4500
001
2430232
005
20250519115925.5
006
m o d
007
cr|nu||||||||
008
261011s2023 miu||||||m |||||||eng d
020
$a
9798379951146
035
$a
(MiAaPQD)AAI30310204
035
$a
AAI30310204
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Ghosh, Dipannita,
$e
author.
$3
3818454
245
1 0
$a
Graphene-Conductive Ink Coated Laser Engraved Kapton Electrochemical Biosensor for the Detection of Dopamine and Immune Sensing /
$c
Dipannita Ghosh.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2023
300
$a
1 electronic resource (79 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 85-01.
500
$a
Advisors: Islam, Nazmul Committee members: Ashraf, Ali; Choi, Paul.
502
$b
M.S.E.
$c
The University of Texas Rio Grande Valley
$d
2023.
520
$a
Novel and flexible disposable laser-engraved Kapton (LEK) electrodes modified with graphene conductive inks have been developed for dopamine and Interleukin-6 (IL-6) detection. The LEK sensors exhibit high reproducibility (RSD=0.76%, N=5) and stability (RSD=4.39%, N=15)after multiple bendings, and thus make the sensors ideal for wearable and stretchable bioelectronics applications. We have developed graphene conductive ink- PEDOT:PSS (G-PEDOT:PSS) and polyaniline (G-PANI) based electrode coatings for working electrode modification to improve the sensitivity (41.41 times higher for screen printed electrode with G-PEDPT:PSS ink modification),and limit of detection (LOD) . We have further compared the performance of the fabricated electrodes with commercially available screen-printed electrodes (SPE), screen-printed electrodes modified with G-PEDOT:PSS (SPE/G-PEDOT:PSS) and G-PANI (SPE/G-PANI). SPE/G-PANI has a lower LOD of 0.632 μM, compared to SPE/G-PEDOT:PSS (0.867 μM) and SPE/G-PANI(1.974 μM). The lowest LOD of the LEK/G-PANI sensor (0.4084 μM, S/N=3) suggests that it can be a great alternative to measure dopamine levels in a physiological medium. Additionally, LEK/G-PANI electrode has excellent LOD (2.6234 pg/mL) to detect IL-6.GRAPHENE-CONDUCTIVE INK COATED LASER ENGRAVED KAPTONELECTROCHEMICAL BIOSENSOR FOR THE DETECTION OF DOPAMINE AND IMMUNESENSING.
546
$a
English
590
$a
School code: 1863
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Bioengineering.
$3
657580
650
4
$a
Materials science.
$3
543314
653
$a
Biosensors
653
$a
Electrochemical biosensors
653
$a
Dopamine
653
$a
Immune sensing
690
$a
0544
690
$a
0202
690
$a
0794
710
2
$a
The University of Texas Rio Grande Valley.
$b
Department of Electrical Engineering.
$e
degree granting institution.
$3
3818455
720
1
$a
Islam, Nazmul
$e
degree supervisor.
773
0
$t
Masters Abstracts International
$g
85-01.
790
$a
1863
791
$a
M.S.E.
792
$a
2023
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30310204
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9525927
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login