Investigations Into the Effects of Electrospray Deposition Sample Preparation Parameters on Analyte Signal in MALDI MS Imaging Samples & Correcting Mass Accuracy and Signal Intensity Errors in a MALDI TOF Mass Spectrometer.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Investigations Into the Effects of Electrospray Deposition Sample Preparation Parameters on Analyte Signal in MALDI MS Imaging Samples & Correcting Mass Accuracy and Signal Intensity Errors in a MALDI TOF Mass Spectrometer./
作者:
Malys, Brian J.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2024,
面頁冊數:
179 p.
附註:
Source: Dissertations Abstracts International, Volume: 85-10, Section: B.
Contained By:
Dissertations Abstracts International85-10B.
標題:
Chemistry. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31143643
ISBN:
9798382306209
Investigations Into the Effects of Electrospray Deposition Sample Preparation Parameters on Analyte Signal in MALDI MS Imaging Samples & Correcting Mass Accuracy and Signal Intensity Errors in a MALDI TOF Mass Spectrometer.
Malys, Brian J.
Investigations Into the Effects of Electrospray Deposition Sample Preparation Parameters on Analyte Signal in MALDI MS Imaging Samples & Correcting Mass Accuracy and Signal Intensity Errors in a MALDI TOF Mass Spectrometer.
- Ann Arbor : ProQuest Dissertations & Theses, 2024 - 179 p.
Source: Dissertations Abstracts International, Volume: 85-10, Section: B.
Thesis (Ph.D.)--Drexel University, 2024.
The thesis consists of three sections. In the first, depth profiles are collected and used to investigate the effects of electrospray deposition (ESD) parameters on matrix deposition for matrix-assisted laser desorption ionization (MALDI) mass spectrometry imaging (MSI) samples. Various matrix deposition parameters including spray time, spray height and matrix identity were varied and the resulting signal of three analytes was collected in sequential spectra using a small number of laser shots. It was found that the spray parameters have a significant effect on the resulting analyte signal and its distribution throughout the matrix overlayer, with homogeneous and heterogeneous distributions of analyte signal observed. The differences in analyte distributions are explained using the fundamental principles of ESD. By identifying the sections of the matrix overlayer with the most analyte signal present, much higher quality MALDI MS images can be collected.In the second section, the use of ESD to apply matrix with an additional solvent spray to incorporate and homogenize analyte within the matrix overlayer was demonstrated. Prior to this incorporation spray, samples prepared using alpha-cyano-4-hydroxycinnamic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB) as the matrix showed low signal while the sample using sinapinic acid (SA) initially exhibited good signal. Following the incorporation spray, the sample using SA did not show an increase in signal, the sample using DHB showed moderate gains, while CHCA samples saw large increases in signal. The use of an incorporation spray to apply solvent by ESD to a matrix layer already deposited by ESD provides an increase in signal by both promoting incorporation of the analyte within and homogenizing the distribution of the incorporated analyte throughout the matrix layer.In the final section, ESD samples were used to determine the source of error in both mass accuracy and signal intensity in a MALDI time-of-flight (TOF) mass spectrometer (MS). This source of error was found to be due to small differences in the initial position of ions formed in the source region of the TOF MS. These differences arise largely from misalignment of the instrument sample stage, with a smaller contribution arising from the non-ideal shape of the target plates used. By physically measuring the target plates used and comparing TOF data collected from three different instruments, an estimate of the magnitude and direction of the sample stage misalignment was determined for each of the instruments. A correction method was developed to correct the TOFs and peak areas obtained for a given combination of target plate and instrument, significantly decreased the error observed.
ISBN: 9798382306209Subjects--Topical Terms:
516420
Chemistry.
Subjects--Index Terms:
Time-of-flight
Investigations Into the Effects of Electrospray Deposition Sample Preparation Parameters on Analyte Signal in MALDI MS Imaging Samples & Correcting Mass Accuracy and Signal Intensity Errors in a MALDI TOF Mass Spectrometer.
LDR
:04088nmm a2200409 4500
001
2402211
005
20241028051456.5
006
m o d
007
cr#unu||||||||
008
251215s2024 ||||||||||||||||| ||eng d
020
$a
9798382306209
035
$a
(MiAaPQ)AAI31143643
035
$a
AAI31143643
035
$a
2402211
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Malys, Brian J.
$0
(orcid)0000-0002-5819-1896
$3
3772435
245
1 0
$a
Investigations Into the Effects of Electrospray Deposition Sample Preparation Parameters on Analyte Signal in MALDI MS Imaging Samples & Correcting Mass Accuracy and Signal Intensity Errors in a MALDI TOF Mass Spectrometer.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2024
300
$a
179 p.
500
$a
Source: Dissertations Abstracts International, Volume: 85-10, Section: B.
500
$a
Advisor: Owens, Kevin G.;Foley, Joe.
502
$a
Thesis (Ph.D.)--Drexel University, 2024.
520
$a
The thesis consists of three sections. In the first, depth profiles are collected and used to investigate the effects of electrospray deposition (ESD) parameters on matrix deposition for matrix-assisted laser desorption ionization (MALDI) mass spectrometry imaging (MSI) samples. Various matrix deposition parameters including spray time, spray height and matrix identity were varied and the resulting signal of three analytes was collected in sequential spectra using a small number of laser shots. It was found that the spray parameters have a significant effect on the resulting analyte signal and its distribution throughout the matrix overlayer, with homogeneous and heterogeneous distributions of analyte signal observed. The differences in analyte distributions are explained using the fundamental principles of ESD. By identifying the sections of the matrix overlayer with the most analyte signal present, much higher quality MALDI MS images can be collected.In the second section, the use of ESD to apply matrix with an additional solvent spray to incorporate and homogenize analyte within the matrix overlayer was demonstrated. Prior to this incorporation spray, samples prepared using alpha-cyano-4-hydroxycinnamic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB) as the matrix showed low signal while the sample using sinapinic acid (SA) initially exhibited good signal. Following the incorporation spray, the sample using SA did not show an increase in signal, the sample using DHB showed moderate gains, while CHCA samples saw large increases in signal. The use of an incorporation spray to apply solvent by ESD to a matrix layer already deposited by ESD provides an increase in signal by both promoting incorporation of the analyte within and homogenizing the distribution of the incorporated analyte throughout the matrix layer.In the final section, ESD samples were used to determine the source of error in both mass accuracy and signal intensity in a MALDI time-of-flight (TOF) mass spectrometer (MS). This source of error was found to be due to small differences in the initial position of ions formed in the source region of the TOF MS. These differences arise largely from misalignment of the instrument sample stage, with a smaller contribution arising from the non-ideal shape of the target plates used. By physically measuring the target plates used and comparing TOF data collected from three different instruments, an estimate of the magnitude and direction of the sample stage misalignment was determined for each of the instruments. A correction method was developed to correct the TOFs and peak areas obtained for a given combination of target plate and instrument, significantly decreased the error observed.
590
$a
School code: 0065.
650
4
$a
Chemistry.
$3
516420
650
4
$a
Physical chemistry.
$3
1981412
650
4
$a
Analytical chemistry.
$3
3168300
653
$a
Time-of-flight
653
$a
Electrospray deposition
653
$a
MALDI
653
$a
Mass spectrometry
653
$a
Analyte signal
653
$a
Mass accuracy
690
$a
0485
690
$a
0486
690
$a
0494
710
2
$a
Drexel University.
$b
Chemistry (College of Arts and Sciences).
$3
3173551
773
0
$t
Dissertations Abstracts International
$g
85-10B.
790
$a
0065
791
$a
Ph.D.
792
$a
2024
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31143643
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9510531
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入