Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Modeling Thermosyphon and Heat Pipe ...
~
Sarkar, Dwaipayan.
Linked to FindBook
Google Book
Amazon
博客來
Modeling Thermosyphon and Heat Pipe Performance for Mold Cooling Applications.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Modeling Thermosyphon and Heat Pipe Performance for Mold Cooling Applications./
Author:
Sarkar, Dwaipayan.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2024,
Description:
372 p.
Notes:
Source: Dissertations Abstracts International, Volume: 85-11, Section: B.
Contained By:
Dissertations Abstracts International85-11B.
Subject:
Industrial engineering. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31272777
ISBN:
9798382232560
Modeling Thermosyphon and Heat Pipe Performance for Mold Cooling Applications.
Sarkar, Dwaipayan.
Modeling Thermosyphon and Heat Pipe Performance for Mold Cooling Applications.
- Ann Arbor : ProQuest Dissertations & Theses, 2024 - 372 p.
Source: Dissertations Abstracts International, Volume: 85-11, Section: B.
Thesis (Ph.D.)--The University of Western Ontario (Canada), 2024.
Thermosyphons are enhanced heat transfer devices that can continuously transfer very large amounts of heat rapidly over long distances with small temperature differences. The high heat transfer rate is achieved through simultaneous boiling and condensation of the working fluid and the continuous heat transfer is achieved through recirculation of the working fluid in its liquid and vapor phase. A potentially important application of the thermosyphons has been towards reducing the cycle times of the mold cooling processes which would provide economic incentives to the automotive industry. Different operational and geometrical parameters such as the input heating power, fill ratio (FR), aspect ratio (AR) and orientation influence the thermodynamic state of the working fluid and the boiling and condensation thermal resistances. The goal of the present work is to develop a more rigorous understanding of the thermal performance of thermosyphons as a function of their design parameters and operating conditions. A thermodynamic model is developed to predict the thermodynamic state of the working fluid and its related properties inside a thermosyphon and heat pipe at each stage of the thermodynamic cycle. The model can predict the operating temperature of a thermosyphon and a heat pipe under a given geometrical and operating condition. The existing predictive heat transfer correlations for estimating the boiling and condensation thermal resistances for thermosyphons are inadequate and lack consistency. Using non-dimensional analysis based on the Buckingham-pi theorem, a series of analytical expressions capable of predicting the boiling and condensation thermal resistance under different operational parameters are developed. The thermal performance of ten distilled-water copper thermosyphons is experimentally investigated by varying the input heating power between 6.68 [W] and 32.98 [W], fill ratio between 0.35 - 0.75 and aspect ratio between 5.33 and 12.43 to understand the relationship between these operating parameters and the boiling and condensation thermal resistances. The present experimental data when compared to the new thermal resistance expressions showed excellent agreement (± 15%). The previous experimental data, however, showed a slightly worse agreement (± 30%), which could be attributed to the overall energy balance and the uncertainties in the reported fill ratio. The results from this work can be useful for selecting thermosyphons for specific applications and optimize the existing design of thermosyphons.
ISBN: 9798382232560Subjects--Topical Terms:
526216
Industrial engineering.
Subjects--Index Terms:
Thermosyphons
Modeling Thermosyphon and Heat Pipe Performance for Mold Cooling Applications.
LDR
:03778nmm a2200385 4500
001
2399500
005
20240916065500.5
006
m o d
007
cr#unu||||||||
008
251215s2024 ||||||||||||||||| ||eng d
020
$a
9798382232560
035
$a
(MiAaPQ)AAI31272777
035
$a
(MiAaPQ)oaiirlibuwocaetd12807
035
$a
AAI31272777
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Sarkar, Dwaipayan.
$3
3769473
245
1 0
$a
Modeling Thermosyphon and Heat Pipe Performance for Mold Cooling Applications.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2024
300
$a
372 p.
500
$a
Source: Dissertations Abstracts International, Volume: 85-11, Section: B.
500
$a
Advisor: DeGroot, Christopher;Savory, Eric.
502
$a
Thesis (Ph.D.)--The University of Western Ontario (Canada), 2024.
520
$a
Thermosyphons are enhanced heat transfer devices that can continuously transfer very large amounts of heat rapidly over long distances with small temperature differences. The high heat transfer rate is achieved through simultaneous boiling and condensation of the working fluid and the continuous heat transfer is achieved through recirculation of the working fluid in its liquid and vapor phase. A potentially important application of the thermosyphons has been towards reducing the cycle times of the mold cooling processes which would provide economic incentives to the automotive industry. Different operational and geometrical parameters such as the input heating power, fill ratio (FR), aspect ratio (AR) and orientation influence the thermodynamic state of the working fluid and the boiling and condensation thermal resistances. The goal of the present work is to develop a more rigorous understanding of the thermal performance of thermosyphons as a function of their design parameters and operating conditions. A thermodynamic model is developed to predict the thermodynamic state of the working fluid and its related properties inside a thermosyphon and heat pipe at each stage of the thermodynamic cycle. The model can predict the operating temperature of a thermosyphon and a heat pipe under a given geometrical and operating condition. The existing predictive heat transfer correlations for estimating the boiling and condensation thermal resistances for thermosyphons are inadequate and lack consistency. Using non-dimensional analysis based on the Buckingham-pi theorem, a series of analytical expressions capable of predicting the boiling and condensation thermal resistance under different operational parameters are developed. The thermal performance of ten distilled-water copper thermosyphons is experimentally investigated by varying the input heating power between 6.68 [W] and 32.98 [W], fill ratio between 0.35 - 0.75 and aspect ratio between 5.33 and 12.43 to understand the relationship between these operating parameters and the boiling and condensation thermal resistances. The present experimental data when compared to the new thermal resistance expressions showed excellent agreement (± 15%). The previous experimental data, however, showed a slightly worse agreement (± 30%), which could be attributed to the overall energy balance and the uncertainties in the reported fill ratio. The results from this work can be useful for selecting thermosyphons for specific applications and optimize the existing design of thermosyphons.
590
$a
School code: 0784.
650
4
$a
Industrial engineering.
$3
526216
650
4
$a
Thermodynamics.
$3
517304
653
$a
Thermosyphons
653
$a
Heat pipes
653
$a
Buckingham pi-theorem
653
$a
Copper thermosyphon
653
$a
Thermal resistance
690
$a
0546
690
$a
0348
710
2
$a
The University of Western Ontario (Canada).
$3
1017622
773
0
$t
Dissertations Abstracts International
$g
85-11B.
790
$a
0784
791
$a
Ph.D.
792
$a
2024
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31272777
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9507820
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login