語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Characterization of Gafchromic HD-V2...
~
Azman, Muhammad Taufiq.
FindBook
Google Book
Amazon
博客來
Characterization of Gafchromic HD-V2 Film for Dose Verification in Stereotactic Radiosurgery (SRS).
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Characterization of Gafchromic HD-V2 Film for Dose Verification in Stereotactic Radiosurgery (SRS)./
作者:
Azman, Muhammad Taufiq.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2018,
面頁冊數:
67 p.
附註:
Source: Masters Abstracts International, Volume: 85-04.
Contained By:
Masters Abstracts International85-04.
標題:
Silicon. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30599423
ISBN:
9798380458320
Characterization of Gafchromic HD-V2 Film for Dose Verification in Stereotactic Radiosurgery (SRS).
Azman, Muhammad Taufiq.
Characterization of Gafchromic HD-V2 Film for Dose Verification in Stereotactic Radiosurgery (SRS).
- Ann Arbor : ProQuest Dissertations & Theses, 2018 - 67 p.
Source: Masters Abstracts International, Volume: 85-04.
Thesis (M.S.)--University of Malaya (Malaysia), 2018.
The purpose of this study was to characterize specific dosimetric properties of Gafchromic HD-V2 film and to investigate its feasibility in the dosimetric verification for Stereotactic Radiosurgery (SRS). Basic dosimeter properties including energy and dose rate dependencies were investigated and HD-V2 film showed energy and dose rate dependencies of less than 9.5% and 4.94% respectively. The HD-V2 film has very low dependency on scanning orientation in portrait versus landscape as well as "face-up" versus "face-down" scanning orientation. The percentage differences recorded were less than 2.7% for portrait versus landscape and less than 2.5% for "face-up" versus "facedown" orientation. In terms of angular dependency, there was no significant influence on net optical density, with deviations less than 4.3% for films irradiated at selected gantry angles ranging from 0° (which film is perpendicular to the irradiation beam) to 180°. Two treatment plans using SRS technique were created and irradiated using HD-V2 film for dosimetric verification. The dose distributions were calculated using a treatment planning system to obtain point doses at specified positions within a phantom. The calculated doses from TPS were compared to dose distributions delivered to HD-V2 film. The results of the point dose measurements for SRS treatment irradiations showed that the deviations between the TPS predicted dose and HD-V2 film measurements were less 4% which were within the recommended values by ICRU. This study shows that Gafchromic HD-V2 film can be used as dosimetric verification for SRS and for radiotherapy clinical practices that involves high range of doses of 10 to 1000 Gy.
ISBN: 9798380458320Subjects--Topical Terms:
669429
Silicon.
Characterization of Gafchromic HD-V2 Film for Dose Verification in Stereotactic Radiosurgery (SRS).
LDR
:02798nmm a2200373 4500
001
2399012
005
20240909062217.5
006
m o d
007
cr#unu||||||||
008
251215s2018 ||||||||||||||||| ||eng d
020
$a
9798380458320
035
$a
(MiAaPQ)AAI30599423
035
$a
(MiAaPQ)Malayastudentsrepoumedumy11570
035
$a
AAI30599423
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Azman, Muhammad Taufiq.
$3
3768977
245
1 0
$a
Characterization of Gafchromic HD-V2 Film for Dose Verification in Stereotactic Radiosurgery (SRS).
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2018
300
$a
67 p.
500
$a
Source: Masters Abstracts International, Volume: 85-04.
500
$a
Advisor: Min, Ung Ngie.
502
$a
Thesis (M.S.)--University of Malaya (Malaysia), 2018.
520
$a
The purpose of this study was to characterize specific dosimetric properties of Gafchromic HD-V2 film and to investigate its feasibility in the dosimetric verification for Stereotactic Radiosurgery (SRS). Basic dosimeter properties including energy and dose rate dependencies were investigated and HD-V2 film showed energy and dose rate dependencies of less than 9.5% and 4.94% respectively. The HD-V2 film has very low dependency on scanning orientation in portrait versus landscape as well as "face-up" versus "face-down" scanning orientation. The percentage differences recorded were less than 2.7% for portrait versus landscape and less than 2.5% for "face-up" versus "facedown" orientation. In terms of angular dependency, there was no significant influence on net optical density, with deviations less than 4.3% for films irradiated at selected gantry angles ranging from 0° (which film is perpendicular to the irradiation beam) to 180°. Two treatment plans using SRS technique were created and irradiated using HD-V2 film for dosimetric verification. The dose distributions were calculated using a treatment planning system to obtain point doses at specified positions within a phantom. The calculated doses from TPS were compared to dose distributions delivered to HD-V2 film. The results of the point dose measurements for SRS treatment irradiations showed that the deviations between the TPS predicted dose and HD-V2 film measurements were less 4% which were within the recommended values by ICRU. This study shows that Gafchromic HD-V2 film can be used as dosimetric verification for SRS and for radiotherapy clinical practices that involves high range of doses of 10 to 1000 Gy.
590
$a
School code: 1293.
650
4
$a
Silicon.
$3
669429
650
4
$a
Polyesters.
$3
686152
650
4
$a
Diodes.
$3
673996
650
4
$a
Radiosurgery.
$3
1084362
650
4
$a
Scanners.
$3
3562953
650
4
$a
Semiconductors.
$3
516162
650
4
$a
Sensors.
$3
3549539
650
4
$a
Oncology.
$3
751006
650
4
$a
Fluorides.
$3
620981
650
4
$a
Energy.
$3
876794
650
4
$a
Dosimetry.
$3
3687072
650
4
$a
Transistors.
$3
713271
650
4
$a
Radiation therapy.
$3
3557731
650
4
$a
Reproducibility.
$3
3683754
650
4
$a
Lithium.
$3
1638490
650
4
$a
X-rays.
$3
604695
650
4
$a
Nuclear physics.
$3
517741
650
4
$a
Physics.
$3
516296
650
4
$a
Plastics.
$3
649803
650
4
$a
Therapy.
$3
3343697
690
$a
0791
690
$a
0992
690
$a
0756
690
$a
0605
690
$a
0795
690
$a
0212
710
2
$a
University of Malaya (Malaysia).
$3
3700764
773
0
$t
Masters Abstracts International
$g
85-04.
790
$a
1293
791
$a
M.S.
792
$a
2018
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30599423
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9507332
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入