語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Modeling of Advanced Heat Pump Cycle...
~
mei, Zhenyuan.
FindBook
Google Book
Amazon
博客來
Modeling of Advanced Heat Pump Cycles and Aerodynamic Design of a Small-Scale Centrifugal Compressor for Electric Vehicles.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Modeling of Advanced Heat Pump Cycles and Aerodynamic Design of a Small-Scale Centrifugal Compressor for Electric Vehicles./
作者:
mei, Zhenyuan.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2023,
面頁冊數:
164 p.
附註:
Source: Dissertations Abstracts International, Volume: 84-12, Section: A.
Contained By:
Dissertations Abstracts International84-12A.
標題:
Mechanical engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30420852
ISBN:
9798379752835
Modeling of Advanced Heat Pump Cycles and Aerodynamic Design of a Small-Scale Centrifugal Compressor for Electric Vehicles.
mei, Zhenyuan.
Modeling of Advanced Heat Pump Cycles and Aerodynamic Design of a Small-Scale Centrifugal Compressor for Electric Vehicles.
- Ann Arbor : ProQuest Dissertations & Theses, 2023 - 164 p.
Source: Dissertations Abstracts International, Volume: 84-12, Section: A.
Thesis (Ph.D.)--University of Maryland, College Park, 2023.
This item must not be sold to any third party vendors.
Unlike conventional vehicles powered by internal combustion engines, electric vehicles do not have enough waste heat to provide sufficient heating to the cabin. Thus, an additional heating system, such as a heat pump, is needed. However, its performance decreases significantly when the ambient temperature is low. The new kangaroo heat pump cycle (KC) is proposed to increase the heating capacity in low-temperature climates. It is an enhanced flash tank-based vapor injection heat pump cycle (FT-VIC). A sub-cycle is added to the system to increase the refrigerant inlet quality entering the flash tank, which leads to a higher refrigerant mass flow rate and heating capacity. Because KC has a higher heating capacity, the heating needed from the electric heater can be reduced, thus reducing energy consumption and increasing the driving distance. In this study, thermodynamic models were developed for the basic heat pump cycle (BC), FT-VIC, and KC. And a new method evaluating the life cycle climate performance (LCCP) of electric vehicle heat pumps based on the SAE J2766 standard was proposed. Results show that KC is effective at low ambient temperatures. At -15°C, KC can save 13.8% energy compared to BC, and save 2.7% energy compared to FT-VIC. However, due to the additional weight, KC has a higher LCCP than other cycles. If the pressure ratio limit is removed and the compressor efficiencies are constant, KC can have a lower LCCP than other cycles in cold climates. Transient models were also developed to assess their performance in urban driving conditions. Results show that at the end of the simulation, the cabin room temperature of KC is 3.6°C and 7.0°C higher than that of FT-VIC and BC, respectively. However, due to the high pressure ratio and refrigerant mass flow rate, the accumulated power consumption of KC is 32.4% higher than FT-VIC and 64.4% higher than BC. Despite its high energy consumption, it is more efficient than adding heat from an electric heater. In addition, a small-scale centrifugal compressor was designed for an electric vehicle to reduce the compressor's size and weight. Results show that its COP is 6.6% higher than that of the scroll compressor at the design point. However, its efficiency at the off-design point quickly drops. Future studies are needed to improve its off-design point performance.
ISBN: 9798379752835Subjects--Topical Terms:
649730
Mechanical engineering.
Subjects--Index Terms:
Centrifugal compressor
Modeling of Advanced Heat Pump Cycles and Aerodynamic Design of a Small-Scale Centrifugal Compressor for Electric Vehicles.
LDR
:03686nmm a2200409 4500
001
2395477
005
20240517104602.5
006
m o d
007
cr#unu||||||||
008
251215s2023 ||||||||||||||||| ||eng d
020
$a
9798379752835
035
$a
(MiAaPQ)AAI30420852
035
$a
AAI30420852
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
mei, Zhenyuan.
$0
(orcid)0000-0001-8569-6286
$3
3764983
245
1 0
$a
Modeling of Advanced Heat Pump Cycles and Aerodynamic Design of a Small-Scale Centrifugal Compressor for Electric Vehicles.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2023
300
$a
164 p.
500
$a
Source: Dissertations Abstracts International, Volume: 84-12, Section: A.
500
$a
Advisor: Radermacher, Reinhard;Hwang, Yunho.
502
$a
Thesis (Ph.D.)--University of Maryland, College Park, 2023.
506
$a
This item must not be sold to any third party vendors.
520
$a
Unlike conventional vehicles powered by internal combustion engines, electric vehicles do not have enough waste heat to provide sufficient heating to the cabin. Thus, an additional heating system, such as a heat pump, is needed. However, its performance decreases significantly when the ambient temperature is low. The new kangaroo heat pump cycle (KC) is proposed to increase the heating capacity in low-temperature climates. It is an enhanced flash tank-based vapor injection heat pump cycle (FT-VIC). A sub-cycle is added to the system to increase the refrigerant inlet quality entering the flash tank, which leads to a higher refrigerant mass flow rate and heating capacity. Because KC has a higher heating capacity, the heating needed from the electric heater can be reduced, thus reducing energy consumption and increasing the driving distance. In this study, thermodynamic models were developed for the basic heat pump cycle (BC), FT-VIC, and KC. And a new method evaluating the life cycle climate performance (LCCP) of electric vehicle heat pumps based on the SAE J2766 standard was proposed. Results show that KC is effective at low ambient temperatures. At -15°C, KC can save 13.8% energy compared to BC, and save 2.7% energy compared to FT-VIC. However, due to the additional weight, KC has a higher LCCP than other cycles. If the pressure ratio limit is removed and the compressor efficiencies are constant, KC can have a lower LCCP than other cycles in cold climates. Transient models were also developed to assess their performance in urban driving conditions. Results show that at the end of the simulation, the cabin room temperature of KC is 3.6°C and 7.0°C higher than that of FT-VIC and BC, respectively. However, due to the high pressure ratio and refrigerant mass flow rate, the accumulated power consumption of KC is 32.4% higher than FT-VIC and 64.4% higher than BC. Despite its high energy consumption, it is more efficient than adding heat from an electric heater. In addition, a small-scale centrifugal compressor was designed for an electric vehicle to reduce the compressor's size and weight. Results show that its COP is 6.6% higher than that of the scroll compressor at the design point. However, its efficiency at the off-design point quickly drops. Future studies are needed to improve its off-design point performance.
590
$a
School code: 0117.
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Automotive engineering.
$3
2181195
650
4
$a
Design.
$3
518875
653
$a
Centrifugal compressor
653
$a
Electric vehicle
653
$a
Heat pump
653
$a
LCCP
653
$a
Mobile air conditioner
653
$a
Transient simulation
690
$a
0548
690
$a
0540
690
$a
0389
710
2
$a
University of Maryland, College Park.
$b
Mechanical Engineering.
$3
1018396
773
0
$t
Dissertations Abstracts International
$g
84-12A.
790
$a
0117
791
$a
Ph.D.
792
$a
2023
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30420852
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9503797
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入