Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Linked to FindBook
Google Book
Amazon
博客來
The Effect of Cone Beam CT Voxel Size on the Identification of Vertical and Horizontal Root Fractures : = An In-Vitro Study.
Record Type:
Electronic resources : Monograph/item
Title/Author:
The Effect of Cone Beam CT Voxel Size on the Identification of Vertical and Horizontal Root Fractures :/
Reminder of title:
An In-Vitro Study.
Author:
Amintavakoli, Niloufar.
Description:
1 online resource (97 pages)
Notes:
Source: Masters Abstracts International, Volume: 76-06.
Contained By:
Masters Abstracts International76-06.
Subject:
Dentistry. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1570684click for full text (PQDT)
ISBN:
9781321397949
The Effect of Cone Beam CT Voxel Size on the Identification of Vertical and Horizontal Root Fractures : = An In-Vitro Study.
Amintavakoli, Niloufar.
The Effect of Cone Beam CT Voxel Size on the Identification of Vertical and Horizontal Root Fractures :
An In-Vitro Study. - 1 online resource (97 pages)
Source: Masters Abstracts International, Volume: 76-06.
Thesis (M.Sc.)--University of Toronto (Canada), 2013.
Includes bibliographical references
Objective: The purpose of this study is to determine the relationship between cone beam CT (CBCT) voxel size and tooth root fracture detection. Materials and Methods: Vertical and horizontal root fractures were induced in a total of 30 teeth, and 15 teeth were left intact. Teeth were imaged with projection digital radiography and the Kodak 9000 3D CBCT system with a native voxel size of 76 μm. The CBCT voxels were then downsampled to 100 μm, 200 μm and 300 μm. Five blinded observers evaluated both sets of images with a 1 week washout interval between each set of observations. Results: CBCT outperformed the projection images for fracture detection for all voxel sizes except 300 μm (p0.05). Conclusion: Although voxel size does not impact the interpretation of root fractures, in vitro, CBCT outperformed projection imaging for voxel sizes less than 300 andmu;m.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9781321397949Subjects--Topical Terms:
828971
Dentistry.
Subjects--Index Terms:
Cone beam CTIndex Terms--Genre/Form:
542853
Electronic books.
The Effect of Cone Beam CT Voxel Size on the Identification of Vertical and Horizontal Root Fractures : = An In-Vitro Study.
LDR
:02246nmm a2200373K 4500
001
2360615
005
20231009073457.5
006
m o d
007
cr mn ---uuuuu
008
241011s2013 xx obm 000 0 eng d
020
$a
9781321397949
035
$a
(MiAaPQ)AAI1570684
035
$a
(MiAaPQ)utoronto:42669
035
$a
AAI1570684
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Amintavakoli, Niloufar.
$3
3701236
245
1 4
$a
The Effect of Cone Beam CT Voxel Size on the Identification of Vertical and Horizontal Root Fractures :
$b
An In-Vitro Study.
264
0
$c
2013
300
$a
1 online resource (97 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 76-06.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Lam, Ernest W.
502
$a
Thesis (M.Sc.)--University of Toronto (Canada), 2013.
504
$a
Includes bibliographical references
520
$a
Objective: The purpose of this study is to determine the relationship between cone beam CT (CBCT) voxel size and tooth root fracture detection. Materials and Methods: Vertical and horizontal root fractures were induced in a total of 30 teeth, and 15 teeth were left intact. Teeth were imaged with projection digital radiography and the Kodak 9000 3D CBCT system with a native voxel size of 76 μm. The CBCT voxels were then downsampled to 100 μm, 200 μm and 300 μm. Five blinded observers evaluated both sets of images with a 1 week washout interval between each set of observations. Results: CBCT outperformed the projection images for fracture detection for all voxel sizes except 300 μm (p0.05). Conclusion: Although voxel size does not impact the interpretation of root fractures, in vitro, CBCT outperformed projection imaging for voxel sizes less than 300 andmu;m.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Dentistry.
$3
828971
653
$a
Cone beam CT
653
$a
Root fractures
653
$a
Voxel size
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0567
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
University of Toronto (Canada).
$b
Dentistry.
$3
3434121
773
0
$t
Masters Abstracts International
$g
76-06.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1570684
$z
click for full text (PQDT)
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9482971
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login