Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Attachment ventilation theory
~
Li, Angui.
Linked to FindBook
Google Book
Amazon
博客來
Attachment ventilation theory
Record Type:
Electronic resources : Monograph/item
Title/Author:
Attachment ventilation theory/ by Angui Li.
Author:
Li, Angui.
Published:
Singapore :Springer Nature Singapore : : 2023.,
Description:
xxiii, 185 p. :ill. (some col.), digital ;24 cm.
[NT 15003449]:
Cooking history and development of kitchen appliances -- Kitchen ventilation requirements -- Pollutions of cooking oil fume and health risks -- Thermal comfort in kitchen -- Basis to calculate exhaust airflow rate -- Design of kitchen ventilation -- High performance kitchen ventilation -- Stack effects of kitchen exhaust shaft in high-rise building -- Case study and design of kitchen ventilation.
Contained By:
Springer Nature eBook
Subject:
Ventilation - Technological innovations. -
Online resource:
https://doi.org/10.1007/978-981-19-9259-9
ISBN:
9789811992599
Attachment ventilation theory
Li, Angui.
Attachment ventilation theory
[electronic resource] /by Angui Li. - Singapore :Springer Nature Singapore :2023. - xxiii, 185 p. :ill. (some col.), digital ;24 cm.
Cooking history and development of kitchen appliances -- Kitchen ventilation requirements -- Pollutions of cooking oil fume and health risks -- Thermal comfort in kitchen -- Basis to calculate exhaust airflow rate -- Design of kitchen ventilation -- High performance kitchen ventilation -- Stack effects of kitchen exhaust shaft in high-rise building -- Case study and design of kitchen ventilation.
Open access.
This open access book systematically summarizes the current research progress of attachment ventilation, covering vertical wall attachment, column attachment, and adaptive attachment ventilation. Attachment ventilation is a high-performance ventilation mode that was first proposed by the author, Prof. Angui Li 20 years ago. Now it has been widely used in office spaces, subway stations, high-speed railway stations, international airport terminals, and other large spaces. This book introduces attachment ventilation in detail to eliminate the cooling/heating load of the occupied zone and provide an expected environment for the air-conditioned zone. Attachment ventilation combines the advantages of traditional mixed ventilation and displacement ventilation. This book consists of six chapters, covering a series of airflow patterns, mechanisms, parameter correlations, and attachment ventilation design methods. It is helpful for HVAC engineers to design attachment ventilation effectively.
ISBN: 9789811992599
Standard No.: 10.1007/978-981-19-9259-9doiSubjects--Topical Terms:
3631757
Ventilation
--Technological innovations.
LC Class. No.: TH7678
Dewey Class. No.: 697.92
Attachment ventilation theory
LDR
:02369nmm a2200337 a 4500
001
2317557
003
DE-He213
005
20230502081823.0
006
m d
007
cr nn 008maaau
008
230902s2023 si s 0 eng d
020
$a
9789811992599
$q
(electronic bk.)
020
$a
9789811992582
$q
(paper)
024
7
$a
10.1007/978-981-19-9259-9
$2
doi
035
$a
978-981-19-9259-9
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
TH7678
072
7
$a
TNKH
$2
bicssc
072
7
$a
TEC009020
$2
bisacsh
072
7
$a
TNKE
$2
thema
082
0 4
$a
697.92
$2
23
090
$a
TH7678
$b
.L693 2023
100
1
$a
Li, Angui.
$3
2055148
245
1 0
$a
Attachment ventilation theory
$h
[electronic resource] /
$c
by Angui Li.
260
$a
Singapore :
$b
Springer Nature Singapore :
$b
Imprint: Springer,
$c
2023.
300
$a
xxiii, 185 p. :
$b
ill. (some col.), digital ;
$c
24 cm.
505
0
$a
Cooking history and development of kitchen appliances -- Kitchen ventilation requirements -- Pollutions of cooking oil fume and health risks -- Thermal comfort in kitchen -- Basis to calculate exhaust airflow rate -- Design of kitchen ventilation -- High performance kitchen ventilation -- Stack effects of kitchen exhaust shaft in high-rise building -- Case study and design of kitchen ventilation.
506
$a
Open access.
520
$a
This open access book systematically summarizes the current research progress of attachment ventilation, covering vertical wall attachment, column attachment, and adaptive attachment ventilation. Attachment ventilation is a high-performance ventilation mode that was first proposed by the author, Prof. Angui Li 20 years ago. Now it has been widely used in office spaces, subway stations, high-speed railway stations, international airport terminals, and other large spaces. This book introduces attachment ventilation in detail to eliminate the cooling/heating load of the occupied zone and provide an expected environment for the air-conditioned zone. Attachment ventilation combines the advantages of traditional mixed ventilation and displacement ventilation. This book consists of six chapters, covering a series of airflow patterns, mechanisms, parameter correlations, and attachment ventilation design methods. It is helpful for HVAC engineers to design attachment ventilation effectively.
650
0
$a
Ventilation
$x
Technological innovations.
$3
3631757
650
1 4
$a
Building Physics, HVAC.
$3
2055153
650
2 4
$a
Engineering Fluid Dynamics.
$3
891349
650
2 4
$a
Building Information Modeling.
$3
3598693
650
2 4
$a
Computer Modelling.
$3
3538541
710
2
$a
SpringerLink (Online service)
$3
836513
773
0
$t
Springer Nature eBook
856
4 0
$u
https://doi.org/10.1007/978-981-19-9259-9
950
$a
Engineering (SpringerNature-11647)
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9453807
電子資源
11.線上閱覽_V
電子書
EB TH7678
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login