Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
A Ne W Method to Estimate the Impact...
~
Al-lababidi, Suhaib.
Linked to FindBook
Google Book
Amazon
博客來
A Ne W Method to Estimate the Impact on the L5/Si Spinal Disc from Speed Lifting of Unstable Loads, Asymmetrically.
Record Type:
Electronic resources : Monograph/item
Title/Author:
A Ne W Method to Estimate the Impact on the L5/Si Spinal Disc from Speed Lifting of Unstable Loads, Asymmetrically./
Author:
Al-lababidi, Suhaib.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2020,
Description:
100 p.
Notes:
Source: Masters Abstracts International, Volume: 82-06.
Contained By:
Masters Abstracts International82-06.
Subject:
Industrial engineering. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28208250
ISBN:
9798678167774
A Ne W Method to Estimate the Impact on the L5/Si Spinal Disc from Speed Lifting of Unstable Loads, Asymmetrically.
Al-lababidi, Suhaib.
A Ne W Method to Estimate the Impact on the L5/Si Spinal Disc from Speed Lifting of Unstable Loads, Asymmetrically.
- Ann Arbor : ProQuest Dissertations & Theses, 2020 - 100 p.
Source: Masters Abstracts International, Volume: 82-06.
Thesis (M.Eng.)--The University of Texas at Arlington, 2020.
This item must not be sold to any third party vendors.
Background: The most significant causes of lower back injuries at work are probably from manual lifting activities. Lifting unstable loads pose a significant strain to the lower back and can cause debilitating lumbar spine injuries. The primary function of the vertebral column is to support the upper body. The L5/S1 disc junction located between the lumbar and the sacral regions of the vertebral column is the most critical joint in spine with respect to lifting strain. Because of its position and the amount of upper body weight it handles, it is particularly vulnerable to misalignment, wear and tear, and injury. Lifting loads has several adverse effects on the back: spinal compression and excessive strain on the back's tendons and ligaments may result in herniated or ruptured discs, disc degenerations, spinal stenosis, and other diseases. Biomechanical models have been developed to estimate the forces in the lumbar spine to determine the severity of lifting tasks, and NIOSH has developed an equation to determine a safe lifting load weight. However, neither covers all important types of lifting conditions adequately. The NIOSH equation does not include the lifting load type (stable versus unstable loads) as a variable due to insufficient research information, and the measurement of spinal force and body motion variables still need improvements to adequately measure and assess the severity of lifting unstable loads asymmetrically. Objective: The main objective of this study is to demonstrate a new method to measure compression, shear, and torque forces in L5/S1 disc when lifting unstable loads under different lifting conditions (load type, lifting style, and lifting speed). different lifting conditions (load type, lifting style, and lifting speed).Methods: A total of 3 subjects volunteered for this study to lift a bin, partly filled with water, with various lifting conditions while standing on force plates. Each subject lifted the bin (stable and unstable load) at two different speeds (normal and fast), and along two different planes of the body (sagittal and frontal) - a total of 8 lifting conditions. The water induced the required instability in the load during lifting. For simulating stable loads (of the same weight - 30 lb) solids replaced water in the same bin. Body joint angles, velocities, accelerations (using a visual 3D Vicon camera system), and forces from force plates and load cells along with 12 electromyography (EMG) signals for detecting muscle contractions were used to determine compression, shear and lateral forces on the L5/S1 disc. To get a more precise force impact on the L5/S1 disc, a technical coordinate system was created to define the orientation of the L5/S1 disc. A bottom-up approach of Newton-Euler dynamics was used using visual 3D software to estimate compression, shear, and torque force on estimated virtual landmark of L5/S1 disc. Results: This study has provided an alternative method to measure compression, shear, and torque forces at estimated location of L5/S1 disc proximal to the technical virtual landmarks. The results have shown to be consistent with other published research papers.
ISBN: 9798678167774Subjects--Topical Terms:
526216
Industrial engineering.
Subjects--Index Terms:
l5/s1 compression disc
A Ne W Method to Estimate the Impact on the L5/Si Spinal Disc from Speed Lifting of Unstable Loads, Asymmetrically.
LDR
:04381nmm a2200361 4500
001
2276779
005
20210510091909.5
008
220723s2020 ||||||||||||||||| ||eng d
020
$a
9798678167774
035
$a
(MiAaPQ)AAI28208250
035
$a
(MiAaPQ)2502vireo2099Al-lababidi
035
$a
AAI28208250
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Al-lababidi, Suhaib.
$3
3555075
245
1 0
$a
A Ne W Method to Estimate the Impact on the L5/Si Spinal Disc from Speed Lifting of Unstable Loads, Asymmetrically.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2020
300
$a
100 p.
500
$a
Source: Masters Abstracts International, Volume: 82-06.
500
$a
Advisor: Sheik, Imrhan;Ricard, Mark.
502
$a
Thesis (M.Eng.)--The University of Texas at Arlington, 2020.
506
$a
This item must not be sold to any third party vendors.
520
$a
Background: The most significant causes of lower back injuries at work are probably from manual lifting activities. Lifting unstable loads pose a significant strain to the lower back and can cause debilitating lumbar spine injuries. The primary function of the vertebral column is to support the upper body. The L5/S1 disc junction located between the lumbar and the sacral regions of the vertebral column is the most critical joint in spine with respect to lifting strain. Because of its position and the amount of upper body weight it handles, it is particularly vulnerable to misalignment, wear and tear, and injury. Lifting loads has several adverse effects on the back: spinal compression and excessive strain on the back's tendons and ligaments may result in herniated or ruptured discs, disc degenerations, spinal stenosis, and other diseases. Biomechanical models have been developed to estimate the forces in the lumbar spine to determine the severity of lifting tasks, and NIOSH has developed an equation to determine a safe lifting load weight. However, neither covers all important types of lifting conditions adequately. The NIOSH equation does not include the lifting load type (stable versus unstable loads) as a variable due to insufficient research information, and the measurement of spinal force and body motion variables still need improvements to adequately measure and assess the severity of lifting unstable loads asymmetrically. Objective: The main objective of this study is to demonstrate a new method to measure compression, shear, and torque forces in L5/S1 disc when lifting unstable loads under different lifting conditions (load type, lifting style, and lifting speed). different lifting conditions (load type, lifting style, and lifting speed).Methods: A total of 3 subjects volunteered for this study to lift a bin, partly filled with water, with various lifting conditions while standing on force plates. Each subject lifted the bin (stable and unstable load) at two different speeds (normal and fast), and along two different planes of the body (sagittal and frontal) - a total of 8 lifting conditions. The water induced the required instability in the load during lifting. For simulating stable loads (of the same weight - 30 lb) solids replaced water in the same bin. Body joint angles, velocities, accelerations (using a visual 3D Vicon camera system), and forces from force plates and load cells along with 12 electromyography (EMG) signals for detecting muscle contractions were used to determine compression, shear and lateral forces on the L5/S1 disc. To get a more precise force impact on the L5/S1 disc, a technical coordinate system was created to define the orientation of the L5/S1 disc. A bottom-up approach of Newton-Euler dynamics was used using visual 3D software to estimate compression, shear, and torque force on estimated virtual landmark of L5/S1 disc. Results: This study has provided an alternative method to measure compression, shear, and torque forces at estimated location of L5/S1 disc proximal to the technical virtual landmarks. The results have shown to be consistent with other published research papers.
590
$a
School code: 2502.
650
4
$a
Industrial engineering.
$3
526216
650
4
$a
Musical performances.
$3
3175508
653
$a
l5/s1 compression disc
653
$a
Unstable loads
653
$a
Asymmetrical lifting
653
$a
Fast speed lifting
690
$a
0546
690
$a
0943
710
2
$a
The University of Texas at Arlington.
$b
Industrial and Manufacturing Systems Engineering.
$3
3350190
773
0
$t
Masters Abstracts International
$g
82-06.
790
$a
2502
791
$a
M.Eng.
792
$a
2020
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28208250
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9428513
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login