Multivariate data analysis for root ...
~
SpringerLink (Online service)
Linked to FindBook
Google Book
Amazon
博客來
Multivariate data analysis for root cause analyses and time-of-flight secondary ion mass spectrometry
Record Type:
Electronic resources : Monograph/item
Title/Author:
Multivariate data analysis for root cause analyses and time-of-flight secondary ion mass spectrometry/ by Danica Heller-Krippendorf.
Author:
Heller-Krippendorf, Danica.
Published:
Wiesbaden :Springer Fachmedien Wiesbaden : : 2019.,
Description:
xix, 195 p. :ill. (some col.), digital ;24 cm.
[NT 15003449]:
Advantages of Correlation Loadings for MVA of ToF-SIMS Spectra -- Required Number of Replicate Measurements in an Industrial Context -- Selection of Suitable Data Pre-processing in Root Cause Analysis Including the Selection of an Efficient Peak List, Scaling, Normalization and Centering -- New Presentation of PCA Results in Order to Simplify Data Analysis.
Contained By:
Springer eBooks
Subject:
Time-of-flight mass spectrometry. -
Online resource:
https://doi.org/10.1007/978-3-658-28502-9
ISBN:
9783658285029
Multivariate data analysis for root cause analyses and time-of-flight secondary ion mass spectrometry
Heller-Krippendorf, Danica.
Multivariate data analysis for root cause analyses and time-of-flight secondary ion mass spectrometry
[electronic resource] /by Danica Heller-Krippendorf. - Wiesbaden :Springer Fachmedien Wiesbaden :2019. - xix, 195 p. :ill. (some col.), digital ;24 cm.
Advantages of Correlation Loadings for MVA of ToF-SIMS Spectra -- Required Number of Replicate Measurements in an Industrial Context -- Selection of Suitable Data Pre-processing in Root Cause Analysis Including the Selection of an Efficient Peak List, Scaling, Normalization and Centering -- New Presentation of PCA Results in Order to Simplify Data Analysis.
Danica Heller-Krippendorf develops concepts and approaches optimizing the applicability of MVA on data sets from an industrial context. They enable more time-efficient MVA of the respective ToF SIMS data. Priority is given to two main aspects by the author: First, the focus is on strategies for a more time-efficient collection of the input data. This includes the optimal selection of the number of replicate measurements, the selection of input data and guidelines for the selection appropriate data preprocessing methods. Second, strategies for more efficient analysis of MVA results are presented. Contents Advantages of Correlation Loadings for MVA of ToF-SIMS Spectra Required Number of Replicate Measurements in an Industrial Context Selection of Suitable Data Pre-processing in Root Cause Analysis Including the Selection of an Efficient Peak List, Scaling, Normalization and Centering New Presentation of PCA Results in Order to Simplify Data Analysis Target Groups Scientists and students in the field of surface analysis, data evaluation, ToF-SIMS and methods of multivariate data analysis Practitioners, especially in industry, in the field of surface and error analysis About the Author Danica Heller-Krippendorf did her research and dissertation at the University of Siegen, Germany, in collaboration with a German analytical service company. Now she is engineer in analytics at a DAX company.
ISBN: 9783658285029
Standard No.: 10.1007/978-3-658-28502-9doiSubjects--Topical Terms:
885130
Time-of-flight mass spectrometry.
LC Class. No.: QC454.M3 / H455 2019
Dewey Class. No.: 543.65
Multivariate data analysis for root cause analyses and time-of-flight secondary ion mass spectrometry
LDR
:02821nmm a2200325 a 4500
001
2218749
003
DE-He213
005
20200117160207.0
006
m d
007
cr nn 008maaau
008
201126s2019 gw s 0 eng d
020
$a
9783658285029
$q
(electronic bk.)
020
$a
9783658285012
$q
(paper)
024
7
$a
10.1007/978-3-658-28502-9
$2
doi
035
$a
978-3-658-28502-9
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
QC454.M3
$b
H455 2019
072
7
$a
PNFS
$2
bicssc
072
7
$a
SCI078000
$2
bisacsh
072
7
$a
PNFS
$2
thema
082
0 4
$a
543.65
$2
23
090
$a
QC454.M3
$b
H477 2019
100
1
$a
Heller-Krippendorf, Danica.
$3
3453352
245
1 0
$a
Multivariate data analysis for root cause analyses and time-of-flight secondary ion mass spectrometry
$h
[electronic resource] /
$c
by Danica Heller-Krippendorf.
260
$a
Wiesbaden :
$b
Springer Fachmedien Wiesbaden :
$b
Imprint: Springer Spektrum,
$c
2019.
300
$a
xix, 195 p. :
$b
ill. (some col.), digital ;
$c
24 cm.
505
0
$a
Advantages of Correlation Loadings for MVA of ToF-SIMS Spectra -- Required Number of Replicate Measurements in an Industrial Context -- Selection of Suitable Data Pre-processing in Root Cause Analysis Including the Selection of an Efficient Peak List, Scaling, Normalization and Centering -- New Presentation of PCA Results in Order to Simplify Data Analysis.
520
$a
Danica Heller-Krippendorf develops concepts and approaches optimizing the applicability of MVA on data sets from an industrial context. They enable more time-efficient MVA of the respective ToF SIMS data. Priority is given to two main aspects by the author: First, the focus is on strategies for a more time-efficient collection of the input data. This includes the optimal selection of the number of replicate measurements, the selection of input data and guidelines for the selection appropriate data preprocessing methods. Second, strategies for more efficient analysis of MVA results are presented. Contents Advantages of Correlation Loadings for MVA of ToF-SIMS Spectra Required Number of Replicate Measurements in an Industrial Context Selection of Suitable Data Pre-processing in Root Cause Analysis Including the Selection of an Efficient Peak List, Scaling, Normalization and Centering New Presentation of PCA Results in Order to Simplify Data Analysis Target Groups Scientists and students in the field of surface analysis, data evaluation, ToF-SIMS and methods of multivariate data analysis Practitioners, especially in industry, in the field of surface and error analysis About the Author Danica Heller-Krippendorf did her research and dissertation at the University of Siegen, Germany, in collaboration with a German analytical service company. Now she is engineer in analytics at a DAX company.
650
0
$a
Time-of-flight mass spectrometry.
$3
885130
650
0
$a
Multivariate analysis.
$3
517467
650
1 4
$a
Mass Spectrometry.
$3
683779
650
2 4
$a
Applied and Technical Physics.
$3
1245150
650
2 4
$a
Spectroscopy/Spectrometry.
$3
1084899
710
2
$a
SpringerLink (Online service)
$3
836513
773
0
$t
Springer eBooks
856
4 0
$u
https://doi.org/10.1007/978-3-658-28502-9
950
$a
Chemistry and Materials Science (Springer-11644)
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9393608
電子資源
11.線上閱覽_V
電子書
EB QC454.M3 H455 2019
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login