Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Structural and Functional Biomedical...
~
Black, Adam J.
Linked to FindBook
Google Book
Amazon
博客來
Structural and Functional Biomedical Imaging Using Polarization-Based Optical Coherence Tomography.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Structural and Functional Biomedical Imaging Using Polarization-Based Optical Coherence Tomography./
Author:
Black, Adam J.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2015,
Description:
117 p.
Notes:
Source: Dissertations Abstracts International, Volume: 79-07, Section: B.
Contained By:
Dissertations Abstracts International79-07B.
Subject:
Biomedical engineering. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10187337
ISBN:
9780355417739
Structural and Functional Biomedical Imaging Using Polarization-Based Optical Coherence Tomography.
Black, Adam J.
Structural and Functional Biomedical Imaging Using Polarization-Based Optical Coherence Tomography.
- Ann Arbor : ProQuest Dissertations & Theses, 2015 - 117 p.
Source: Dissertations Abstracts International, Volume: 79-07, Section: B.
Thesis (Ph.D.)--University of Minnesota, 2015.
This item must not be added to any third party search indexes.
Biomedical imaging has had an enormous impact in medicine and research. There are numerous imaging modalities covering a large range of spatial and temporal scales, penetration depths, along with indicators for function and disease. As these imaging technologies mature, the quality of the images they produce increases to resolve finer details with greater contrast at higher speeds which aids in a faster, more accurate diagnosis in the clinic. In this dissertation, polarization-based optical coherence tomography (OCT) systems are used and developed to image biological structure and function with greater speeds, signal-to-noise (SNR) and stability. OCT can image with spatial and temporal resolutions in the micro range. When imaging any sample, feedback is very important to verify the fidelity and desired location on the sample being imaged. To increase frame rates for display as well as data throughput, field-programmable gate arrays (FPGAs) were used with custom algorithms to realize real-time display and streaming output for continuous acquisition of large datasets of swept-source OCT systems. For spectral domain (SD) OCT systems, significant increases in signal-to-noise ratios were achieved from a custom balanced detection (BD) OCT system. The BD system doubled measured signals while reducing common term. For functional imaging, a real-time directed scanner was introduced to visualize the 3D image of a sample to identify regions of interest prior to recording. Elucidating the characteristics of functional OCT signals with the aid of simulations, novel processing methods were also developed to stabilize samples being imaged and identify possible origins of functional signals being measured. Polarization-sensitive OCT was used to image cardiac tissue before and after clearing to identify the regions of vascular perfusion from a coronary artery. The resulting 3D image provides a visualization of the perfusion boundaries for the tissue that would be damaged from a myocardial infarction to possibly identity features that lead to fatal cardiac arrhythmias. 3D functional imaging was used to measure functional retinal activity from a light stimulus. In some cases, single trial responses were possible; measured at the outer segment of the photoreceptor layer. The morphology and time-course of these signals are similar to the intrinsic optical signals reported from phototransduction. Assessing function in the retina could aid in early detection of degenerative diseases of the retina, such as glaucoma and macular degeneration.
ISBN: 9780355417739Subjects--Topical Terms:
535387
Biomedical engineering.
Structural and Functional Biomedical Imaging Using Polarization-Based Optical Coherence Tomography.
LDR
:03727nmm a2200337 4500
001
2207171
005
20190916101756.5
008
201008s2015 ||||||||||||||||| ||eng d
020
$a
9780355417739
035
$a
(MiAaPQ)AAI10187337
035
$a
(MiAaPQ)umn:16462
035
$a
AAI10187337
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Black, Adam J.
$3
3434115
245
1 0
$a
Structural and Functional Biomedical Imaging Using Polarization-Based Optical Coherence Tomography.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2015
300
$a
117 p.
500
$a
Source: Dissertations Abstracts International, Volume: 79-07, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Akkin, Taner.
502
$a
Thesis (Ph.D.)--University of Minnesota, 2015.
506
$a
This item must not be added to any third party search indexes.
506
$a
This item must not be sold to any third party vendors.
520
$a
Biomedical imaging has had an enormous impact in medicine and research. There are numerous imaging modalities covering a large range of spatial and temporal scales, penetration depths, along with indicators for function and disease. As these imaging technologies mature, the quality of the images they produce increases to resolve finer details with greater contrast at higher speeds which aids in a faster, more accurate diagnosis in the clinic. In this dissertation, polarization-based optical coherence tomography (OCT) systems are used and developed to image biological structure and function with greater speeds, signal-to-noise (SNR) and stability. OCT can image with spatial and temporal resolutions in the micro range. When imaging any sample, feedback is very important to verify the fidelity and desired location on the sample being imaged. To increase frame rates for display as well as data throughput, field-programmable gate arrays (FPGAs) were used with custom algorithms to realize real-time display and streaming output for continuous acquisition of large datasets of swept-source OCT systems. For spectral domain (SD) OCT systems, significant increases in signal-to-noise ratios were achieved from a custom balanced detection (BD) OCT system. The BD system doubled measured signals while reducing common term. For functional imaging, a real-time directed scanner was introduced to visualize the 3D image of a sample to identify regions of interest prior to recording. Elucidating the characteristics of functional OCT signals with the aid of simulations, novel processing methods were also developed to stabilize samples being imaged and identify possible origins of functional signals being measured. Polarization-sensitive OCT was used to image cardiac tissue before and after clearing to identify the regions of vascular perfusion from a coronary artery. The resulting 3D image provides a visualization of the perfusion boundaries for the tissue that would be damaged from a myocardial infarction to possibly identity features that lead to fatal cardiac arrhythmias. 3D functional imaging was used to measure functional retinal activity from a light stimulus. In some cases, single trial responses were possible; measured at the outer segment of the photoreceptor layer. The morphology and time-course of these signals are similar to the intrinsic optical signals reported from phototransduction. Assessing function in the retina could aid in early detection of degenerative diseases of the retina, such as glaucoma and macular degeneration.
590
$a
School code: 0130.
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Optics.
$3
517925
690
$a
0541
690
$a
0752
710
2
$a
University of Minnesota.
$b
Biomedical Engineering.
$3
1669049
773
0
$t
Dissertations Abstracts International
$g
79-07B.
790
$a
0130
791
$a
Ph.D.
792
$a
2015
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10187337
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9383720
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login