Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Resonant Sensors for Passive, Real-t...
~
Charkhabi, Sadaf.
Linked to FindBook
Google Book
Amazon
博客來
Resonant Sensors for Passive, Real-time, and Wireless Characterization of Biological Analytes.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Resonant Sensors for Passive, Real-time, and Wireless Characterization of Biological Analytes./
Author:
Charkhabi, Sadaf.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2018,
Description:
87 p.
Notes:
Source: Masters Abstracts International, Volume: 57-06.
Contained By:
Masters Abstracts International57-06(E).
Subject:
Chemical engineering. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10790308
ISBN:
9780438072756
Resonant Sensors for Passive, Real-time, and Wireless Characterization of Biological Analytes.
Charkhabi, Sadaf.
Resonant Sensors for Passive, Real-time, and Wireless Characterization of Biological Analytes.
- Ann Arbor : ProQuest Dissertations & Theses, 2018 - 87 p.
Source: Masters Abstracts International, Volume: 57-06.
Thesis (M.S.)--Iowa State University, 2018.
This item is not available from ProQuest Dissertations & Theses.
A passive, low-cost resonant sensor was developed with the potential application of wireless monitoring of hydrolytic enzyme activity in closed systems. The resonators are rapidly prototyped from polyimide substrates (25microm thickness) which are coated with a thin layer of copper (35microm thickness). The patterns of the resonators, which are Archimedean spirals, are drawn on these substrates using an indelible marker with an XY plotter. These substrates are etched with a solution containing hydrogen peroxide and hydrochloric acid in order to remove the undesired copper.
ISBN: 9780438072756Subjects--Topical Terms:
560457
Chemical engineering.
Resonant Sensors for Passive, Real-time, and Wireless Characterization of Biological Analytes.
LDR
:03596nmm a2200337 4500
001
2204947
005
20190718114218.5
008
201008s2018 ||||||||||||||||| ||eng d
020
$a
9780438072756
035
$a
(MiAaPQ)AAI10790308
035
$a
(MiAaPQ)iastate:17299
035
$a
AAI10790308
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Charkhabi, Sadaf.
$3
3431815
245
1 0
$a
Resonant Sensors for Passive, Real-time, and Wireless Characterization of Biological Analytes.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2018
300
$a
87 p.
500
$a
Source: Masters Abstracts International, Volume: 57-06.
500
$a
Adviser: Nigel F. Reuel.
502
$a
Thesis (M.S.)--Iowa State University, 2018.
506
$a
This item is not available from ProQuest Dissertations & Theses.
520
$a
A passive, low-cost resonant sensor was developed with the potential application of wireless monitoring of hydrolytic enzyme activity in closed systems. The resonators are rapidly prototyped from polyimide substrates (25microm thickness) which are coated with a thin layer of copper (35microm thickness). The patterns of the resonators, which are Archimedean spirals, are drawn on these substrates using an indelible marker with an XY plotter. These substrates are etched with a solution containing hydrogen peroxide and hydrochloric acid in order to remove the undesired copper.
520
$a
The initial resonant frequency of these resonators can be controlled by the Archimedean coil length and pitch size of the spiral. The frequency response window is tuned for the 1-100 MHz range for better penetration through soil, water, and tissue. The resonant frequency can be measured up to 5cm stand-off distance by a 3D-printed coplanar, two-loop coil reader antenna. This reader is attached to a vector network analyzer for monitoring the magnitude of S21 scattering parameter. The central hypothesis is that the Archimedean spiral sensors respond to any change in relative permittivity of the medium in contact with the resonator. This response is represented as a clear shift in the resonant frequency of the resonator. For instance, changing the medium from air to water results in approximately 50MHz redshift in the resonant frequency.
520
$a
In order to measure hydrolytic enzyme activity, the resonant sensors are coated by an enzyme substrate (e.g. hydrogel). The degradation of the enzyme substrate causes a change in the relative permittivity which results in a shift in the resonant frequency (up to 7MHz redshift). By fitting a transport-reaction model, which simulates the radial digestion profile, on the experimental data the activity (turnover rate, or kcat value) of the enzyme is calculated. This approach is used for testing purified Subtilisin A and unpurified bacterial protease samples at different concentrations ranging from 30mg/ml to 200mg/ml with kcat values of 0.003-0.002 and 0.009-0.004 gsubstrate /genzyme per second, respectively. The sensor response rate can be tuned by changing the substrate composition (i.e. changing the gelatin and glycerol plasticizer weight percentage in the hydrogel). Finally, the applicability of these resonant sensors in a real-life problem is demonstrated by wirelessly measuring the proteolytic activity of farm soil with a measured kcat of 0.00152 gsubstrate/(gsoil˙s) using 3D-printed plastic cases.
590
$a
School code: 0097.
650
4
$a
Chemical engineering.
$3
560457
650
4
$a
Soil sciences.
$3
2122699
690
$a
0542
690
$a
0481
710
2
$a
Iowa State University.
$b
Chemical and Biological Engineering.
$3
1286910
773
0
$t
Masters Abstracts International
$g
57-06(E).
790
$a
0097
791
$a
M.S.
792
$a
2018
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10790308
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9381496
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login