Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Powerline contamination in time-doma...
~
Bloss, Benjamin R.
Linked to FindBook
Google Book
Amazon
博客來
Powerline contamination in time-domain electromagnetic data: Experiment, theory, and basic building blocks.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Powerline contamination in time-domain electromagnetic data: Experiment, theory, and basic building blocks./
Author:
Bloss, Benjamin R.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2017,
Description:
105 p.
Notes:
Source: Masters Abstracts International, Volume: 56-03.
Contained By:
Masters Abstracts International56-03(E).
Subject:
Geophysics. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10255906
ISBN:
9781369632958
Powerline contamination in time-domain electromagnetic data: Experiment, theory, and basic building blocks.
Bloss, Benjamin R.
Powerline contamination in time-domain electromagnetic data: Experiment, theory, and basic building blocks.
- Ann Arbor : ProQuest Dissertations & Theses, 2017 - 105 p.
Source: Masters Abstracts International, Volume: 56-03.
Thesis (M.S.)--Colorado School of Mines, 2017.
Time-domain Electromagnetics (TEM) is a powerful tool to image the conductivity structure of the subsurface. These systems can be ground-based or can be mounted on an airborne platform, which allows for greater data density and resolution. Airborne electromagnetic (AEM) surveys are continually being pushed to regions with increasing culture; regions such as producing oil-fields with a need of ground-water contaminant monitoring, populated agricultural regions for water resource management, and/or mineral exploration around existing developments. Culture and cultural noise are proportional, and powerlines are a common and persistent source of cultural noise.
ISBN: 9781369632958Subjects--Topical Terms:
535228
Geophysics.
Powerline contamination in time-domain electromagnetic data: Experiment, theory, and basic building blocks.
LDR
:03467nmm a2200349 4500
001
2154180
005
20180330130621.5
008
190424s2017 ||||||||||||||||| ||eng d
020
$a
9781369632958
035
$a
(MiAaPQ)AAI10255906
035
$a
(MiAaPQ)mines:11220
035
$a
AAI10255906
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Bloss, Benjamin R.
$3
3341903
245
1 0
$a
Powerline contamination in time-domain electromagnetic data: Experiment, theory, and basic building blocks.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2017
300
$a
105 p.
500
$a
Source: Masters Abstracts International, Volume: 56-03.
500
$a
Includes supplementary digital materials.
500
$a
Adviser: Andrei Swidinsky.
502
$a
Thesis (M.S.)--Colorado School of Mines, 2017.
520
$a
Time-domain Electromagnetics (TEM) is a powerful tool to image the conductivity structure of the subsurface. These systems can be ground-based or can be mounted on an airborne platform, which allows for greater data density and resolution. Airborne electromagnetic (AEM) surveys are continually being pushed to regions with increasing culture; regions such as producing oil-fields with a need of ground-water contaminant monitoring, populated agricultural regions for water resource management, and/or mineral exploration around existing developments. Culture and cultural noise are proportional, and powerlines are a common and persistent source of cultural noise.
520
$a
Powerlines present a unique signature in TEM data. AEM data from Iowa, contracted by the USGS, exemplify these effects. The affected data are smoothly elevated and contamination can be seen as far as 400+ m away from a powerline. Standard data processing techniques simply cull the affected data from the dataset yielding a data loss in excess of 25%. While the problem is well documented in the literature, the basic building blocks of the physics behind the problem are not well understood. This thesis is an attempt to characterize and understand the powerline coupling problem, both theoretically and experimentally.
520
$a
A critical component of this work is the conceptual idea of a Skywire---a vertical loop of wire, simulating powerline grounding structures and their earth return. This concept was tested experimentally---by building a Skywire and performing TEM surveys around it, and studied theoretically---through modeling the coupling of a Skywire to an idealized TEM system. Both approaches show that powerline grounding structures are indeed the culprit, but also suggest that the mutual inductance between the earth and the Skywire plays a large role in the contamination.
520
$a
While the modeling does not fully capture the amplitudes and spatial extent of the contamination observed in AEM or ground-based data, many aspects of the problem were investigated. These aspects include Skywire resistance, Skywire self-inductance, Skywire--earth mutual-inductance, and differing geometries between airborne- and ground-based systems and Skywires. A methodology to repair affected TEM data and recover the earth structure has yet to be developed, however, I present a modeling algorithm and a way to quantify contamination levels in TEM data.
590
$a
School code: 0052.
650
4
$a
Geophysics.
$3
535228
650
4
$a
Electromagnetics.
$3
3173223
690
$a
0373
690
$a
0607
710
2
$a
Colorado School of Mines.
$b
Geophysics.
$3
3174445
773
0
$t
Masters Abstracts International
$g
56-03(E).
790
$a
0052
791
$a
M.S.
792
$a
2017
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10255906
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9353727
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login