PET/MR Imaging of Hypoxic Atherosclerotic Plaque Using 64Cu-ATSM.
Record Type:
Electronic resources : Monograph/item
Title/Author:
PET/MR Imaging of Hypoxic Atherosclerotic Plaque Using 64Cu-ATSM./
Author:
Nie, Xingyu.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2017,
Description:
165 p.
Notes:
Source: Dissertation Abstracts International, Volume: 78-08(E), Section: B.
Contained By:
Dissertation Abstracts International78-08B(E).
Subject:
Medical imaging. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10262628
ISBN:
9781369681628
PET/MR Imaging of Hypoxic Atherosclerotic Plaque Using 64Cu-ATSM.
Nie, Xingyu.
PET/MR Imaging of Hypoxic Atherosclerotic Plaque Using 64Cu-ATSM.
- Ann Arbor : ProQuest Dissertations & Theses, 2017 - 165 p.
Source: Dissertation Abstracts International, Volume: 78-08(E), Section: B.
Thesis (Ph.D.)--Washington University in St. Louis, 2017.
It is important to accurately identify the factors involved in the progression of atherosclerosis because advanced atherosclerotic lesions are prone to rupture, leading to disability or death. Hypoxic areas have been known to be present in human atherosclerotic lesions, and lesion progression is associated with the formation of lipid-loaded macrophages and increased local inflammation which are potential major factors in the formation of vulnerable plaque. This dissertation work represents a comprehensive investigation of non-invasive identification of hypoxic atherosclerotic plaque in animal models and human subjects using the PET hypoxia imaging agent 64Cu-ATSM.
ISBN: 9781369681628Subjects--Topical Terms:
3172799
Medical imaging.
PET/MR Imaging of Hypoxic Atherosclerotic Plaque Using 64Cu-ATSM.
LDR
:02795nmm a2200325 4500
001
2125192
005
20171113075201.5
008
180830s2017 ||||||||||||||||| ||eng d
020
$a
9781369681628
035
$a
(MiAaPQ)AAI10262628
035
$a
AAI10262628
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Nie, Xingyu.
$3
3287243
245
1 0
$a
PET/MR Imaging of Hypoxic Atherosclerotic Plaque Using 64Cu-ATSM.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2017
300
$a
165 p.
500
$a
Source: Dissertation Abstracts International, Volume: 78-08(E), Section: B.
500
$a
Advisers: Pamela K. Woodard; Suzanne Lapi.
502
$a
Thesis (Ph.D.)--Washington University in St. Louis, 2017.
520
$a
It is important to accurately identify the factors involved in the progression of atherosclerosis because advanced atherosclerotic lesions are prone to rupture, leading to disability or death. Hypoxic areas have been known to be present in human atherosclerotic lesions, and lesion progression is associated with the formation of lipid-loaded macrophages and increased local inflammation which are potential major factors in the formation of vulnerable plaque. This dissertation work represents a comprehensive investigation of non-invasive identification of hypoxic atherosclerotic plaque in animal models and human subjects using the PET hypoxia imaging agent 64Cu-ATSM.
520
$a
We first demonstrated the feasibility of 64Cu-ATSM for the identification of hypoxic atherosclerotic plaque and evaluated the relative effects of diet and genetics on hypoxia progression in atherosclerotic plaque in a genetically-altered mouse model. We then fully validated the feasibility of using 64Cu-ATSM to image the extent of hypoxia in a rabbit model with atherosclerotic-like plaque using a simultaneous PET-MR system. We also proceeded with a pilot clinical trial to determine whether 64Cu-ATSM MR/PET scanning is capable of detecting hypoxic carotid atherosclerosis in human subjects.
520
$a
In order to improve the 64Cu-ATSM PET image quality, we investigated the Siemens HD (high-definition) PET software and 4 partial volume correction methods to correct for partial volume effects. In addition, we incorporated the attenuation effect of the carotid surface coil into the MR attenuation correction mu-map to correct for photon attention.
520
$a
In the long term, this imaging strategy has the potential to help identify patients at risk for cardiovascular events, guide therapy, and add to the understanding of plaque biology in human patients.
590
$a
School code: 0252.
650
4
$a
Medical imaging.
$3
3172799
650
4
$a
Biomedical engineering.
$3
535387
690
$a
0574
690
$a
0541
710
2
$a
Washington University in St. Louis.
$b
Biomedical Engineering.
$3
1669544
773
0
$t
Dissertation Abstracts International
$g
78-08B(E).
790
$a
0252
791
$a
Ph.D.
792
$a
2017
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10262628
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9335804
電子資源
01.外借(書)_YB
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login