Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Development of a noninvasive in vivo...
~
Liakat, Sabbir.
Linked to FindBook
Google Book
Amazon
博客來
Development of a noninvasive in vivo glucose sensor based on mid-infrared quantum cascade laser spectroscopy.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Development of a noninvasive in vivo glucose sensor based on mid-infrared quantum cascade laser spectroscopy./
Author:
Liakat, Sabbir.
Description:
144 p.
Notes:
Source: Dissertation Abstracts International, Volume: 76-11(E), Section: B.
Contained By:
Dissertation Abstracts International76-11B(E).
Subject:
Biomedical engineering. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3712609
ISBN:
9781321895476
Development of a noninvasive in vivo glucose sensor based on mid-infrared quantum cascade laser spectroscopy.
Liakat, Sabbir.
Development of a noninvasive in vivo glucose sensor based on mid-infrared quantum cascade laser spectroscopy.
- 144 p.
Source: Dissertation Abstracts International, Volume: 76-11(E), Section: B.
Thesis (Ph.D.)--Princeton University, 2015.
Diabetes mellitus impacts over 340 million people across the world. Diabetics must monitor their glucose levels multiple times a day and currently, the most accurate method of doing so involves pricking one's finger, an often-painful procedure. This dissertation documents research aimed at developing a noninvasive in vivo glucose sensor, with the motivation of implementing a pain-free means of measuring glucose for diabetics. We utilize a novel approach based on mid-infrared (mid-IR) Quantum Cascade (QC) laser spectroscopy. While previous optical solutions using near-IR light between 1300--1900 nm have failed due to limits on glucose absorption feature specificity, the mid-IR region between 8--10 &mgr;m contains strong absorption features with cross-sections up to four orders of magnitude greater than their near-IR counterparts. Although mid-IR spectroscopy has traditionally been neglected for in vivo applications due to the lack of light sources capable of sufficient skin penetration, the advent of powerful QC lasers allows us to overcome this limitation. Here, theoretical background of light-matter interaction is presented, followed by discussion of experimental research progressing towards noninvasive glucose sensing. First, the feasibility of mid-IR noninvasive glucose sensing is shown through measurements of angular scattering patterns in skin, which show that QC laser light can penetrate deep enough into skin. Next, we show clinically accurate sensing of physiological glucose concentrations in vitro using partial least squares regression (PLSR) analysis on mid-IR transmission spectra of proxy solutions for dermal interstitial fluid. Finally, we record breakthrough results showing clinically accurate glucose prediction capability in vivo with human subjects using a setup featuring hollow-core fiber optics, liquid nitrogen cooled detection, and PLSR analysis. This sensor is then made more compact by replacing the fibers with an integrating sphere that significantly increases the collection efficiency of scattered light from skin. This allows the sensor to be housed on a mobile cart, and it removes the system's nitrogen dependency by allowing the use of a thermoelectrically cooled detector, all while maintaining glucose sensing accuracy. We conclude with an outlook for the improved portable sensor to move on from laboratory trials with volunteers to large-scale trials in diabetes clinics.
ISBN: 9781321895476Subjects--Topical Terms:
535387
Biomedical engineering.
Development of a noninvasive in vivo glucose sensor based on mid-infrared quantum cascade laser spectroscopy.
LDR
:03362nmm a2200289 4500
001
2070837
005
20160621141228.5
008
170521s2015 ||||||||||||||||| ||eng d
020
$a
9781321895476
035
$a
(MiAaPQ)AAI3712609
035
$a
AAI3712609
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Liakat, Sabbir.
$3
3185914
245
1 0
$a
Development of a noninvasive in vivo glucose sensor based on mid-infrared quantum cascade laser spectroscopy.
300
$a
144 p.
500
$a
Source: Dissertation Abstracts International, Volume: 76-11(E), Section: B.
500
$a
Adviser: Claire F. Gmachl.
502
$a
Thesis (Ph.D.)--Princeton University, 2015.
520
$a
Diabetes mellitus impacts over 340 million people across the world. Diabetics must monitor their glucose levels multiple times a day and currently, the most accurate method of doing so involves pricking one's finger, an often-painful procedure. This dissertation documents research aimed at developing a noninvasive in vivo glucose sensor, with the motivation of implementing a pain-free means of measuring glucose for diabetics. We utilize a novel approach based on mid-infrared (mid-IR) Quantum Cascade (QC) laser spectroscopy. While previous optical solutions using near-IR light between 1300--1900 nm have failed due to limits on glucose absorption feature specificity, the mid-IR region between 8--10 &mgr;m contains strong absorption features with cross-sections up to four orders of magnitude greater than their near-IR counterparts. Although mid-IR spectroscopy has traditionally been neglected for in vivo applications due to the lack of light sources capable of sufficient skin penetration, the advent of powerful QC lasers allows us to overcome this limitation. Here, theoretical background of light-matter interaction is presented, followed by discussion of experimental research progressing towards noninvasive glucose sensing. First, the feasibility of mid-IR noninvasive glucose sensing is shown through measurements of angular scattering patterns in skin, which show that QC laser light can penetrate deep enough into skin. Next, we show clinically accurate sensing of physiological glucose concentrations in vitro using partial least squares regression (PLSR) analysis on mid-IR transmission spectra of proxy solutions for dermal interstitial fluid. Finally, we record breakthrough results showing clinically accurate glucose prediction capability in vivo with human subjects using a setup featuring hollow-core fiber optics, liquid nitrogen cooled detection, and PLSR analysis. This sensor is then made more compact by replacing the fibers with an integrating sphere that significantly increases the collection efficiency of scattered light from skin. This allows the sensor to be housed on a mobile cart, and it removes the system's nitrogen dependency by allowing the use of a thermoelectrically cooled detector, all while maintaining glucose sensing accuracy. We conclude with an outlook for the improved portable sensor to move on from laboratory trials with volunteers to large-scale trials in diabetes clinics.
590
$a
School code: 0181.
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Optics.
$3
517925
650
4
$a
Engineering.
$3
586835
690
$a
0541
690
$a
0752
690
$a
0537
710
2
$a
Princeton University.
$b
Electrical Engineering.
$3
2095953
773
0
$t
Dissertation Abstracts International
$g
76-11B(E).
790
$a
0181
791
$a
Ph.D.
792
$a
2015
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3712609
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9303705
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login