語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Investigating blood flow and antibio...
~
Meisel, Jayda Erkal.
FindBook
Google Book
Amazon
博客來
Investigating blood flow and antibiotic dosing using traditional microfluidics and novel 3D printed devices.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Investigating blood flow and antibiotic dosing using traditional microfluidics and novel 3D printed devices./
作者:
Meisel, Jayda Erkal.
面頁冊數:
134 p.
附註:
Source: Dissertation Abstracts International, Volume: 76-08(E), Section: B.
Contained By:
Dissertation Abstracts International76-08B(E).
標題:
Biochemistry. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3688513
ISBN:
9781321671858
Investigating blood flow and antibiotic dosing using traditional microfluidics and novel 3D printed devices.
Meisel, Jayda Erkal.
Investigating blood flow and antibiotic dosing using traditional microfluidics and novel 3D printed devices.
- 134 p.
Source: Dissertation Abstracts International, Volume: 76-08(E), Section: B.
Thesis (Ph.D.)--Michigan State University, 2015.
This item must not be sold to any third party vendors.
Over the last 25 years, it has been established that the red blood cell (RBC) is a major determinant in blood flow, which it can modulate through release of adenosine triphosphate (ATP). Although RBCs store intracellular ATP inmMconcentrations, measurements indicate that the cells release nM concentrations when stimulated by deformation, hypoxia (lowered oxygen tension), or incubation with pharmacological stimuli such as hydroxyurea (HU), which is the only approved drug for treatment of sickle cell disease. Upon release, RBC-derived ATP can induce vessel dilation via activation of endothelial cell nitric oxide synthase (eNOS) to produce nitric oxide (NO).
ISBN: 9781321671858Subjects--Topical Terms:
518028
Biochemistry.
Investigating blood flow and antibiotic dosing using traditional microfluidics and novel 3D printed devices.
LDR
:05480nmm a2200325 4500
001
2066485
005
20151106144906.5
008
170521s2015 ||||||||||||||||| ||eng d
020
$a
9781321671858
035
$a
(MiAaPQ)AAI3688513
035
$a
AAI3688513
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Meisel, Jayda Erkal.
$3
3181287
245
1 0
$a
Investigating blood flow and antibiotic dosing using traditional microfluidics and novel 3D printed devices.
300
$a
134 p.
500
$a
Source: Dissertation Abstracts International, Volume: 76-08(E), Section: B.
500
$a
Adviser: Dana M. Spence.
502
$a
Thesis (Ph.D.)--Michigan State University, 2015.
506
$a
This item must not be sold to any third party vendors.
520
$a
Over the last 25 years, it has been established that the red blood cell (RBC) is a major determinant in blood flow, which it can modulate through release of adenosine triphosphate (ATP). Although RBCs store intracellular ATP inmMconcentrations, measurements indicate that the cells release nM concentrations when stimulated by deformation, hypoxia (lowered oxygen tension), or incubation with pharmacological stimuli such as hydroxyurea (HU), which is the only approved drug for treatment of sickle cell disease. Upon release, RBC-derived ATP can induce vessel dilation via activation of endothelial cell nitric oxide synthase (eNOS) to produce nitric oxide (NO).
520
$a
To probe the fate of increased ATP release from human RBCs incubated with the drug hydroxyurea, a traditional soft polymer platform was utilized to facilitate measurement of cell-to-cell communication between RBCs and a cultured endothelium. This device contained an array of micron-scale channels through which RBC samples were pumped. The sample flow was separated from a detection well by a porous polycarbonate membrane. Stimulated ATP released from the RBCs diffused across the membrane to the detection wells and was measured using the luciferinluciferase chemiluminescence assay, integrated with a plate reader for detection. RBCs incubated with 100 muM of HU released on average 2.06 +/- 0.37 times more ATP relative to the control sample. Through the use of various inhibitors, this increase in ATP release was subsequently demonstrated to depend on RBC deformability, RBC NOS activity, and the cystic fibrosis transmembrane conductance regulator protein (CFTR). The fate of the measured RBC-derived ATP was also investigated by probing ATP signalling to an adjacent cultured endothelium.
520
$a
ATP release from RBCs increases in response to hypoxia, or lowered oxygen tension; however, the dependence of RBC ATP release on oxygen tension has not been investigated. To enable measurement of RBC ATP release and oxygen tension in a flowing stream of RBCs, a 3D printed device was designed to accomodate commercial transwell inserts for ATP measurements, as well as threaded Clark-type electrodes for amperometric oxygen measurements. The device consisted of a channel 2 mm wide and 0.5 mm in height with two ports for analyte detection and one threaded port for an electrode. The Clark-type electrode was fabricated from gold and silver wires secured into a finger tight fitting. Oxygen standards and RBC samples were prepared using air and argon purged buffers. Using the 3D printed device, RBC ATP release and oxygen tension were measured simultaneously from prepared RBC samples. Relative to controls, RBC ATP release increased significantly in response to systematically lowered oxygen tension with a maximum increase of 2.38 +/- 0.43 fold more ATP when exposed to 5.35 +/- 0.12 ppm O2. ATP release saturated, i.e., was not significantly different, at lower oxygen tensions. This increase in ATP release was inhibited by incubating RBCs with the cell stiffening agent, diamide. The dependence of hypoxic RBC ATP release on the conformation of heme in hemoglobin (Hb) is demonstrated by converting measured oxygen tensions to Hb saturation.
520
$a
The 3D printed platforms presented herein were also utilized as in vitro tools to model pharmacokinetic dosing profiles, specifically with applications for studying antibiotic resistance. The World Health Organization, Centers for Disease Control, and the White House have issued reports that outline strategies to combat antibiotic resistance. The Spence lab has developed a 3D printed device to mimic in vivo drug dosing profiles on an in vitro platform for applications in drug discovery. This 3D printed diffusion-based dynamic dosing device mimics the dosing capabilities of the hollow fiber chamber reactor (HFCR). The in vitro 3D printed device contains 6 ports to house commercial polyester transwell membrane inserts (0.4 mum) and in house fabricated 0.2 mum pore size inserts (polyester), which can be loaded with a sample of Escherichia coli. Chemically competent, kanamycin resistant E. coli were dosed with the DNA gyrase and topoisomerase IV inhibitor levofloxacin, which reached a maximum concentration (Cmax) of 21.0 +/- 5.7 muM (0.4 mum pore size) and 68.5 +/- 5.0 muM (0.2 mum pore size) of levofloxacin in approximately 1 hour. After dosing, the viability of the bacteria samples was measured using standard plating methods.
590
$a
School code: 0128.
650
4
$a
Biochemistry.
$3
518028
650
4
$a
Physiology.
$3
518431
690
$a
0487
690
$a
0719
710
2
$a
Michigan State University.
$b
Chemistry - Doctor of Philosophy.
$3
2094041
773
0
$t
Dissertation Abstracts International
$g
76-08B(E).
790
$a
0128
791
$a
Ph.D.
792
$a
2015
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3688513
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9299195
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入