Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Towards ultrasound-guided spinal fus...
~
Manbachi, Amir.
Linked to FindBook
Google Book
Amazon
博客來
Towards ultrasound-guided spinal fusion surgery
Record Type:
Electronic resources : Monograph/item
Title/Author:
Towards ultrasound-guided spinal fusion surgery/ by Amir Manbachi.
Author:
Manbachi, Amir.
Published:
Cham :Springer International Publishing : : 2016.,
Description:
xiii, 95 p. :ill. (some col.), digital ;24 cm.
[NT 15003449]:
Introduction -- Background Review -- Organization of Pedicle Trabeculae -- Single Element Transducers -- Ultrasound Imaging Radial Array: Design and Fabrication -- Experimental Evaluation of the Array Performance -- Summary, Limitations and Future Directions.
Contained By:
Springer eBooks
Subject:
Spinal fusion. -
Online resource:
http://dx.doi.org/10.1007/978-3-319-29832-0
ISBN:
9783319298320
Towards ultrasound-guided spinal fusion surgery
Manbachi, Amir.
Towards ultrasound-guided spinal fusion surgery
[electronic resource] /by Amir Manbachi. - Cham :Springer International Publishing :2016. - xiii, 95 p. :ill. (some col.), digital ;24 cm. - Springer theses,2190-5053. - Springer theses..
Introduction -- Background Review -- Organization of Pedicle Trabeculae -- Single Element Transducers -- Ultrasound Imaging Radial Array: Design and Fabrication -- Experimental Evaluation of the Array Performance -- Summary, Limitations and Future Directions.
This thesis describes the design and fabrication of ultrasound probes for pedicle screw guidance. The author details the fabrication of a 2MHz radial array for a pedicle screw insertion eliminating the need for manual rotation of the transducer. He includes radial images obtained from successive groupings of array elements in various fluids. He also examines the manner in which it can affect ultrasound propagation. Nominated as an outstanding Ph.D. thesis by the University of Toronto, Ontario, Canada Describes the design and fabrication of 2Mhz ultrasound probes for pedicle screw guidance Explores radial array designs that eliminate the need for manual rotation of the transducer Depicts a quantitative method for investigating the directionality distribution for analysis of ultrasound propagation with potential uses for a variety of applications.
ISBN: 9783319298320
Standard No.: 10.1007/978-3-319-29832-0doiSubjects--Topical Terms:
2191512
Spinal fusion.
LC Class. No.: RD768
Dewey Class. No.: 617.56059
Towards ultrasound-guided spinal fusion surgery
LDR
:02083nmm a2200325 a 4500
001
2035854
003
DE-He213
005
20161012134607.0
006
m d
007
cr nn 008maaau
008
161117s2016 gw s 0 eng d
020
$a
9783319298320
$q
(electronic bk.)
020
$a
9783319298313
$q
(paper)
024
7
$a
10.1007/978-3-319-29832-0
$2
doi
035
$a
978-3-319-29832-0
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
RD768
072
7
$a
MQW
$2
bicssc
072
7
$a
TEC009000
$2
bisacsh
082
0 4
$a
617.56059
$2
23
090
$a
RD768
$b
.M267 2016
100
1
$a
Manbachi, Amir.
$3
2191511
245
1 0
$a
Towards ultrasound-guided spinal fusion surgery
$h
[electronic resource] /
$c
by Amir Manbachi.
260
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2016.
300
$a
xiii, 95 p. :
$b
ill. (some col.), digital ;
$c
24 cm.
490
1
$a
Springer theses,
$x
2190-5053
505
0
$a
Introduction -- Background Review -- Organization of Pedicle Trabeculae -- Single Element Transducers -- Ultrasound Imaging Radial Array: Design and Fabrication -- Experimental Evaluation of the Array Performance -- Summary, Limitations and Future Directions.
520
$a
This thesis describes the design and fabrication of ultrasound probes for pedicle screw guidance. The author details the fabrication of a 2MHz radial array for a pedicle screw insertion eliminating the need for manual rotation of the transducer. He includes radial images obtained from successive groupings of array elements in various fluids. He also examines the manner in which it can affect ultrasound propagation. Nominated as an outstanding Ph.D. thesis by the University of Toronto, Ontario, Canada Describes the design and fabrication of 2Mhz ultrasound probes for pedicle screw guidance Explores radial array designs that eliminate the need for manual rotation of the transducer Depicts a quantitative method for investigating the directionality distribution for analysis of ultrasound propagation with potential uses for a variety of applications.
650
0
$a
Spinal fusion.
$3
2191512
650
0
$a
Operative ultrasonography.
$3
2018975
650
1 4
$a
Engineering.
$3
586835
650
2 4
$a
Biomedical Engineering.
$3
720279
650
2 4
$a
Optical and Electronic Materials.
$3
891120
650
2 4
$a
Ultrasound.
$3
894572
710
2
$a
SpringerLink (Online service)
$3
836513
773
0
$t
Springer eBooks
830
0
$a
Springer theses.
$3
1314442
856
4 0
$u
http://dx.doi.org/10.1007/978-3-319-29832-0
950
$a
Engineering (Springer-11647)
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9279698
電子資源
11.線上閱覽_V
電子書
EB RD768
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login