Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Collimator-based tracking with an ad...
~
Bohler, Andreas.
Linked to FindBook
Google Book
Amazon
博客來
Collimator-based tracking with an add-on multileaf collimator = modification of a commercial collimator system for realtime applications /
Record Type:
Electronic resources : Monograph/item
Title/Author:
Collimator-based tracking with an add-on multileaf collimator/ by Andreas Bohler.
Reminder of title:
modification of a commercial collimator system for realtime applications /
Author:
Bohler, Andreas.
Published:
Wiesbaden :Springer Fachmedien Wiesbaden : : 2016.,
Description:
xiv, 53 p. :ill., digital ;24 cm.
[NT 15003449]:
1 Introduction -- 2 Literature Overview -- 3 Hypothesis & Goals -- 4 Materials & Methods -- 5 Results -- 6 Discussion -- 7 Conclusions.
Contained By:
Springer eBooks
Subject:
Radiotherapy - Equipment and supplies. -
Online resource:
http://dx.doi.org/10.1007/978-3-658-10658-4
ISBN:
9783658106584$q(electronic bk.)
Collimator-based tracking with an add-on multileaf collimator = modification of a commercial collimator system for realtime applications /
Bohler, Andreas.
Collimator-based tracking with an add-on multileaf collimator
modification of a commercial collimator system for realtime applications /[electronic resource] :by Andreas Bohler. - Wiesbaden :Springer Fachmedien Wiesbaden :2016. - xiv, 53 p. :ill., digital ;24 cm. - BestMedDiss. - BestMedDiss..
1 Introduction -- 2 Literature Overview -- 3 Hypothesis & Goals -- 4 Materials & Methods -- 5 Results -- 6 Discussion -- 7 Conclusions.
In this thesis, a tracking system was developed by modifying an add-on collimator, the Siemens Moduleaf, for realtime applications in radiotherapy. As the add-on collimator works almost completely autonomously of the linear accelerator (LinAc), no modifications to the latter were necessary. The adaptations to the Moduleaf were mainly software-based. In order to reduce the complexity of the system, outdated electronic parts were replaced with newer components where practical. Verification was performed by measuring the latency of the system as well as the impact on applied dose to a predefined target volume, moving in the leaf's travel direction. Latency measurements in software were accomplished by comparing the target and current positions of the leaves. For dose measurements, a Gafchromic EBT2 film was placed beneath the target 4D phantom, in between solid water plates, and moved alongside with it. Based on the results, a tracking-capable add-on collimator seems to be a useful tool for reducing the margins for the treatment of small, slow-moving targets. Radiotherapy is one of the most important methods used for the treatment of cancer. Irradiating a moving target is also one of the most challenging tasks to accomplish in modern radiotherapy.
ISBN: 9783658106584$q(electronic bk.)
Standard No.: 10.1007/978-3-658-10658-4doiSubjects--Topical Terms:
2180409
Radiotherapy
--Equipment and supplies.
LC Class. No.: RM862.5
Dewey Class. No.: 615.842
Collimator-based tracking with an add-on multileaf collimator = modification of a commercial collimator system for realtime applications /
LDR
:02434nmm a2200325 a 4500
001
2029410
003
DE-He213
005
20160727142611.0
006
m d
007
cr nn 008maaau
008
160908s2016 gw s 0 eng d
020
$a
9783658106584$q(electronic bk.)
020
$a
9783658106577$q(paper)
024
7
$a
10.1007/978-3-658-10658-4
$2
doi
035
$a
978-3-658-10658-4
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
RM862.5
072
7
$a
MJCL1
$2
bicssc
072
7
$a
MED080000
$2
bisacsh
082
0 4
$a
615.842
$2
23
090
$a
RM862.5
$b
.B676 2016
100
1
$a
Bohler, Andreas.
$3
2180407
245
1 0
$a
Collimator-based tracking with an add-on multileaf collimator
$h
[electronic resource] :
$b
modification of a commercial collimator system for realtime applications /
$c
by Andreas Bohler.
260
$a
Wiesbaden :
$b
Springer Fachmedien Wiesbaden :
$b
Imprint: Springer,
$c
2016.
300
$a
xiv, 53 p. :
$b
ill., digital ;
$c
24 cm.
490
1
$a
BestMedDiss
505
0
$a
1 Introduction -- 2 Literature Overview -- 3 Hypothesis & Goals -- 4 Materials & Methods -- 5 Results -- 6 Discussion -- 7 Conclusions.
520
$a
In this thesis, a tracking system was developed by modifying an add-on collimator, the Siemens Moduleaf, for realtime applications in radiotherapy. As the add-on collimator works almost completely autonomously of the linear accelerator (LinAc), no modifications to the latter were necessary. The adaptations to the Moduleaf were mainly software-based. In order to reduce the complexity of the system, outdated electronic parts were replaced with newer components where practical. Verification was performed by measuring the latency of the system as well as the impact on applied dose to a predefined target volume, moving in the leaf's travel direction. Latency measurements in software were accomplished by comparing the target and current positions of the leaves. For dose measurements, a Gafchromic EBT2 film was placed beneath the target 4D phantom, in between solid water plates, and moved alongside with it. Based on the results, a tracking-capable add-on collimator seems to be a useful tool for reducing the margins for the treatment of small, slow-moving targets. Radiotherapy is one of the most important methods used for the treatment of cancer. Irradiating a moving target is also one of the most challenging tasks to accomplish in modern radiotherapy.
650
0
$a
Radiotherapy
$x
Equipment and supplies.
$3
2180409
650
0
$a
Collimators (Optical instrument)
$3
2180410
650
1 4
$a
Medicine & Public Health.
$3
890906
650
2 4
$a
Radiotherapy.
$3
862372
650
2 4
$a
Oncology.
$3
751006
710
2
$a
SpringerLink (Online service)
$3
836513
773
0
$t
Springer eBooks
830
0
$a
BestMedDiss.
$3
2180408
856
4 0
$u
http://dx.doi.org/10.1007/978-3-658-10658-4
950
$a
Medicine (Springer-11650)
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9276674
電子資源
11.線上閱覽_V
電子書
EB RM862.5 .B676 2016
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login