語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Development of novel methods for the...
~
Mamunooru, Manasa.
FindBook
Google Book
Amazon
博客來
Development of novel methods for the rapid separation of biomolecules.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Development of novel methods for the rapid separation of biomolecules./
作者:
Mamunooru, Manasa.
面頁冊數:
184 p.
附註:
Source: Dissertation Abstracts International, Volume: 74-06(E), Section: B.
Contained By:
Dissertation Abstracts International74-06B(E).
標題:
Chemistry, General. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3552342
ISBN:
9781267907936
Development of novel methods for the rapid separation of biomolecules.
Mamunooru, Manasa.
Development of novel methods for the rapid separation of biomolecules.
- 184 p.
Source: Dissertation Abstracts International, Volume: 74-06(E), Section: B.
Thesis (Ph.D.)--Temple University, 2013.
Successful methods for the separation of biomolecules like amino acids, proteins, peptides, and DNA have been developed previously using HPLC, GC, GC-MS, and CE. Recently CE has become a routine laboratory technique in the analysis of biological molecules. Even though high-resolution separations with small sample volumes is the main advantage, CE is limited by lower sensitivity detection of analytes when universal detectors like UV absorption or refractive index detectors are used. Therefore, sensitivity enhancement can be obtained by either using different detection schemes or electrophoretically based pre- or on-line concentration methods. These can be grouped into two categories. The first category includes IEF, CGF or TGF where sensitivity is achieved through equilibrium electrofocusing. In these methods, electrophoresis and bulk solution is combined in the capillary or separation column to form a null velocity point, a point at which the net velocity of the analyte is zero. Using these methods 10-10,000 fold sensitivity enhancement is achieved. The second category uses velocity gradients but not the nul velocity for the enrichment of samples. These methods include FASS, LVSS, NSM, etc., which are applied for the analysis of small molecules, and 10-10,000 fold sensitivity enhancement is reported by using these methods.
ISBN: 9781267907936Subjects--Topical Terms:
1021807
Chemistry, General.
Development of novel methods for the rapid separation of biomolecules.
LDR
:04648nam a2200313 4500
001
1967593
005
20141124080558.5
008
150210s2013 ||||||||||||||||| ||eng d
020
$a
9781267907936
035
$a
(MiAaPQ)AAI3552342
035
$a
AAI3552342
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Mamunooru, Manasa.
$3
2104633
245
1 0
$a
Development of novel methods for the rapid separation of biomolecules.
300
$a
184 p.
500
$a
Source: Dissertation Abstracts International, Volume: 74-06(E), Section: B.
500
$a
Adviser: Robert J. Stanley.
502
$a
Thesis (Ph.D.)--Temple University, 2013.
520
$a
Successful methods for the separation of biomolecules like amino acids, proteins, peptides, and DNA have been developed previously using HPLC, GC, GC-MS, and CE. Recently CE has become a routine laboratory technique in the analysis of biological molecules. Even though high-resolution separations with small sample volumes is the main advantage, CE is limited by lower sensitivity detection of analytes when universal detectors like UV absorption or refractive index detectors are used. Therefore, sensitivity enhancement can be obtained by either using different detection schemes or electrophoretically based pre- or on-line concentration methods. These can be grouped into two categories. The first category includes IEF, CGF or TGF where sensitivity is achieved through equilibrium electrofocusing. In these methods, electrophoresis and bulk solution is combined in the capillary or separation column to form a null velocity point, a point at which the net velocity of the analyte is zero. Using these methods 10-10,000 fold sensitivity enhancement is achieved. The second category uses velocity gradients but not the nul velocity for the enrichment of samples. These methods include FASS, LVSS, NSM, etc., which are applied for the analysis of small molecules, and 10-10,000 fold sensitivity enhancement is reported by using these methods.
520
$a
In this work, first GEITP an on-line preconcentration technique is applied for the detection of amino acids (using Trp and Tyr as model analytes). This work also established the effects of different parameters on enrichment. The parameters studied include effect of current flow acceleration across capillary inner diameter, the effect of leading electrolyte (LE) concentration on current density, and the effect of applied electric fields on the current density. To explore the application of GEITP in biological fluids, optimized parameters were developed for the detection and separation of Trp and Tyr in artificial cerebrospinal fluid (aCSF). Next, GEITP was applied for enrichment and separation of physiologically relevant concentrations of chromophore-derivatized Asp and Glu in high conductivity samples like artificial cerebrospinal fluid (aCSF). It was concluded from this work that the major factors which influence the enrichment is the ratio of current density to sample conductivity. Finally, GEITP is applied as a prior step before CZE to increase the resolution between analytes without using ampholyte mixtures. In this method GEITP was combined to CZE to achieve resolution adjustment between amino acids mixture using low pressure hydrodynamic flow during CZE without changing the separation column, field strength, or electrolyte system.
520
$a
In this work, a rapid CE method for extraction and analysis of amino acids in planarians, labeled with 4-Fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F), was developed. This method was applied to detect the changes in the levels of amino acids when planarians were fed and starved. This method can be applied to study pharmacological effects in planaria, as it can monitor different amino acid levels with respect to feeding. Finally, ssDNA photoproducts of different lengths (11-mer and 63-mer) were separated using two different matrices, a traditional C18 and a PV/DBS (PLRP-S) matrix. A faster separation (within ∼ 10 mins) was achieved for a 11-mer by the PLRP-S column. A separation was achieved in the PLRP-S column for the 63-mer while there was no separation in C18 column. Baseline resolution was not achieved. Therefore, C18 can best be used for small length DNA while PLRP-S can be applied for longer length DNA, as it is more hydrophobic than C18 column. Parameters can still be optimized for a baseline separation.
590
$a
School code: 0225.
650
4
$a
Chemistry, General.
$3
1021807
650
4
$a
Chemistry, Analytical.
$3
586156
650
4
$a
Chemistry, Biochemistry.
$3
1017722
690
$a
0485
690
$a
0486
690
$a
0487
710
2
$a
Temple University.
$b
Chemistry.
$3
1029985
773
0
$t
Dissertation Abstracts International
$g
74-06B(E).
790
$a
0225
791
$a
Ph.D.
792
$a
2013
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3552342
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9262599
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入