Determination of aflatoxin M1 using ...
~
Muhammad, Jameelah.
Linked to FindBook
Google Book
Amazon
博客來
Determination of aflatoxin M1 using in milk using disposable pipette extraction (DPX) followed by high performance liquid chromatography (HPLC) analysis.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Determination of aflatoxin M1 using in milk using disposable pipette extraction (DPX) followed by high performance liquid chromatography (HPLC) analysis./
Author:
Muhammad, Jameelah.
Description:
84 p.
Notes:
Source: Masters Abstracts International, Volume: 51-06.
Contained By:
Masters Abstracts International51-06(E).
Subject:
Chemistry, Analytical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1538800
ISBN:
9781303127991
Determination of aflatoxin M1 using in milk using disposable pipette extraction (DPX) followed by high performance liquid chromatography (HPLC) analysis.
Muhammad, Jameelah.
Determination of aflatoxin M1 using in milk using disposable pipette extraction (DPX) followed by high performance liquid chromatography (HPLC) analysis.
- 84 p.
Source: Masters Abstracts International, Volume: 51-06.
Thesis (M.S.)--Western Illinois University, 2013.
Aflatoxin M1 (AFM1), the major hydroxylated metabolite of aflatoxin B1 (AFB1), is considered possibly carcinogenic. It is primarily excreted through the milk and urine of animals that have consumed aflatoxin B1 contaminated feed. Overall, brief exposure to aflatoxins from the diet can lead to disease and death in humans. Since animal milk is utilized for the production of dairy products, the consumption of milk, by humans, provides a direct exposure route for the intake of aflatoxin M1. Because of this, there is a constant need to monitor the AFM 1 content in milk via an uncomplicated method that is both quick and reliable.
ISBN: 9781303127991Subjects--Topical Terms:
586156
Chemistry, Analytical.
Determination of aflatoxin M1 using in milk using disposable pipette extraction (DPX) followed by high performance liquid chromatography (HPLC) analysis.
LDR
:02631nam a2200277 4500
001
1967531
005
20141124080543.5
008
150210s2013 ||||||||||||||||| ||eng d
020
$a
9781303127991
035
$a
(MiAaPQ)AAI1538800
035
$a
AAI1538800
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Muhammad, Jameelah.
$3
2104556
245
1 0
$a
Determination of aflatoxin M1 using in milk using disposable pipette extraction (DPX) followed by high performance liquid chromatography (HPLC) analysis.
300
$a
84 p.
500
$a
Source: Masters Abstracts International, Volume: 51-06.
500
$a
Adviser: Hongxia Guan.
502
$a
Thesis (M.S.)--Western Illinois University, 2013.
520
$a
Aflatoxin M1 (AFM1), the major hydroxylated metabolite of aflatoxin B1 (AFB1), is considered possibly carcinogenic. It is primarily excreted through the milk and urine of animals that have consumed aflatoxin B1 contaminated feed. Overall, brief exposure to aflatoxins from the diet can lead to disease and death in humans. Since animal milk is utilized for the production of dairy products, the consumption of milk, by humans, provides a direct exposure route for the intake of aflatoxin M1. Because of this, there is a constant need to monitor the AFM 1 content in milk via an uncomplicated method that is both quick and reliable.
520
$a
Proposed here is an alternative to the numerous enzyme-linked immunosorbent assay (ELISA), liquid-liquid extraction (LLE) and solid-phase extraction (SPE) techniques currently employed for the extraction of AFM1 from milk. The proposed disposable pipette extraction (DPX) method provided several advantages over these conventional techniques, such as reliability at low concentrations, along with a reduction in time and total organic solvent volume necessary for the extraction process. Upon development of a DPX method, samples were analyzed using high-performance liquid chromatography (HPLC) with UV detection. An elution solvent study, followed by a DPX sorbent study, allowed for maximum analyte recovery; accuracy was shown to be greater than 82%. Lastly, a calibration study, which displayed an R² value of 0.9961, was performed along with other forms of method validation. High precision was shown through relative standard deviations which were lower than 6.76%. The limit of detection (LOD) and limit of quantification (LOQ) were 2.14 ppb and 6.49 ppb, respectively.
590
$a
School code: 6012.
650
4
$a
Chemistry, Analytical.
$3
586156
690
$a
0486
710
2
$a
Western Illinois University.
$b
Chemistry.
$3
2094682
773
0
$t
Masters Abstracts International
$g
51-06(E).
790
$a
6012
791
$a
M.S.
792
$a
2013
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1538800
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9262537
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login