Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Mouse HCI through combined EMG and IMU.
~
Forbes, Timothy.
Linked to FindBook
Google Book
Amazon
博客來
Mouse HCI through combined EMG and IMU.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Mouse HCI through combined EMG and IMU./
Author:
Forbes, Timothy.
Description:
111 p.
Notes:
Source: Masters Abstracts International, Volume: 51-05.
Contained By:
Masters Abstracts International51-05(E).
Subject:
Engineering, Computer. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1536047
ISBN:
9781303035845
Mouse HCI through combined EMG and IMU.
Forbes, Timothy.
Mouse HCI through combined EMG and IMU.
- 111 p.
Source: Masters Abstracts International, Volume: 51-05.
Thesis (M.S.)--University of Rhode Island, 2013.
Since the invention of the computer mouse interface there have been no major changes in its design. The way we interact with computers through keyboards and mice are still the same as they first were. Recent new technologies try to replace or emulate the mouse and each have their own disadvantages. Some require the use of surfaces, cameras, sensor bars, or tethering. Other technologies are gesture based, require training, and are not intuitive. Not only is there the need for a mouse interface that is intuitive and convenient, but advancements in the field of human computer interfacing, especially using electromyogram (EMG) sensors, further open doors. The objective of this project is to design and create a wearable computer mouse interface, independent of cameras, sensor bars, surfaces, or tethering, that is intuitive, fast, accurate and convenient. This is accomplished by combining the output of both EMG sensors and an inertial measurement unit (IMU) to control the cursor and clicking functions of a mouse. The goal is to be intuitive and accurate in order to overcome the shortcomings in existing technologies.
ISBN: 9781303035845Subjects--Topical Terms:
1669061
Engineering, Computer.
Mouse HCI through combined EMG and IMU.
LDR
:04565nam a2200349 4500
001
1966149
005
20141106122623.5
008
150210s2013 ||||||||||||||||| ||eng d
020
$a
9781303035845
035
$a
(MiAaPQ)AAI1536047
035
$a
AAI1536047
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Forbes, Timothy.
$3
2102943
245
1 0
$a
Mouse HCI through combined EMG and IMU.
300
$a
111 p.
500
$a
Source: Masters Abstracts International, Volume: 51-05.
500
$a
Includes supplementary digital materials.
500
$a
Adviser: Qing Yang.
502
$a
Thesis (M.S.)--University of Rhode Island, 2013.
520
$a
Since the invention of the computer mouse interface there have been no major changes in its design. The way we interact with computers through keyboards and mice are still the same as they first were. Recent new technologies try to replace or emulate the mouse and each have their own disadvantages. Some require the use of surfaces, cameras, sensor bars, or tethering. Other technologies are gesture based, require training, and are not intuitive. Not only is there the need for a mouse interface that is intuitive and convenient, but advancements in the field of human computer interfacing, especially using electromyogram (EMG) sensors, further open doors. The objective of this project is to design and create a wearable computer mouse interface, independent of cameras, sensor bars, surfaces, or tethering, that is intuitive, fast, accurate and convenient. This is accomplished by combining the output of both EMG sensors and an inertial measurement unit (IMU) to control the cursor and clicking functions of a mouse. The goal is to be intuitive and accurate in order to overcome the shortcomings in existing technologies.
520
$a
Many different muscles were examined as potential candidates for the EMG sensors. The output of each sensor was observed and several different sensor setups were chosen for focus. For each setup, at least one classifier configuration was designed in the attempt to obtain the highest testing accuracy. The angular velocity measurements of the z and y axis in the IMU were chosen to physically control the mouse cursor. Several different techniques were designed based on the different sensor setups and classifier configurations to obtain the highest overall system accuracy and fewest false positives.
520
$a
Training data was collected in MatLab for processing. Time domain features were extracted and provided as input to a linear discriminant classifier. The implementation of the designs were programed in C++ for fast and efficient real-time performance. The setup and configuration with the highest training accuracy, highest testing accuracy, lowest false positive rate, and best overall IMU integration, was the setup with EMG sensors on the muscles: Extensor Carpi Radialis, Extensor Carpi Ulnaris, Flexor Carpi Ulnaris, Flexor Carpi Radialis, and Flexor Digitorum Superficialis (Near Wrist). One classifier took the input of all five channels for classification into a total of seven classes or actions: Rest, Up, Down, Left, Right, Left Click, and Right Click. This design took the least time to complete the accuracy program designed to evaluate the different configurations. This design also saw the lowest false positives.
520
$a
Compared to a standard mouse or track pad, the best design still fell far short in performance. However, the common user has been using a standard mouse or track pad their whole life, and the need for time to practice with the device is expected. With practice, the design has the potential to match or come close to the accuracy of existing mice. With further automation of the training data collection and classifier training, the device would require little configuration to start using. Further development towards a commercial product would minimize the equipment required, the sensor setup time, and make the device no less convenient than a standard mouse.
520
$a
One of the design goals at the forefront of this project, is the application and usability by hand amputees. Muscle locations are located in the forearm, and the IMU device located on the back of the wrist or forearm, allows hand amputees and those with hand disabilities to operate the device.
590
$a
School code: 0186.
650
4
$a
Engineering, Computer.
$3
1669061
650
4
$a
Computer Science.
$3
626642
650
4
$a
Engineering, Biomedical.
$3
1017684
690
$a
0464
690
$a
0984
690
$a
0541
710
2
$a
University of Rhode Island.
$b
Electrical Engineering.
$3
1682357
773
0
$t
Masters Abstracts International
$g
51-05(E).
790
$a
0186
791
$a
M.S.
792
$a
2013
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1536047
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9261154
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login