Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Biomedical imaging and therapy with ...
~
Khandhar, Amit Praful.
Linked to FindBook
Google Book
Amazon
博客來
Biomedical imaging and therapy with physically and physiologically tailored magnetic nanoparticles.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Biomedical imaging and therapy with physically and physiologically tailored magnetic nanoparticles./
Author:
Khandhar, Amit Praful.
Description:
184 p.
Notes:
Source: Dissertation Abstracts International, Volume: 75-05(E), Section: B.
Contained By:
Dissertation Abstracts International75-05B(E).
Subject:
Engineering, Materials Science. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3608958
ISBN:
9781303675058
Biomedical imaging and therapy with physically and physiologically tailored magnetic nanoparticles.
Khandhar, Amit Praful.
Biomedical imaging and therapy with physically and physiologically tailored magnetic nanoparticles.
- 184 p.
Source: Dissertation Abstracts International, Volume: 75-05(E), Section: B.
Thesis (Ph.D.)--University of Washington, 2013.
Magnetic particle imaging (MPI) and magnetic fluid hyperthermia (MFH) are emerging imaging and therapy approaches that have the potential to improve diagnostic safety and disease management of heart disease and cancer - the number 1 and 2 leading causes of deaths in the United States. MPI promises real-time, tomographic and quantitative imaging of superparamagnetic iron oxide nanoparticle (SPION) tracers distributed in vivo, and is targeted to offer a safer angiography alternative for its first clinical application. MFH uses ac-fields to dissipate heat from SPIONs that can be delivered locally to promote hyperthermia therapy (~42°C) in cancer cells.
ISBN: 9781303675058Subjects--Topical Terms:
1017759
Engineering, Materials Science.
Biomedical imaging and therapy with physically and physiologically tailored magnetic nanoparticles.
LDR
:04612nam a2200325 4500
001
1964657
005
20141010092631.5
008
150210s2013 ||||||||||||||||| ||eng d
020
$a
9781303675058
035
$a
(MiAaPQ)AAI3608958
035
$a
AAI3608958
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Khandhar, Amit Praful.
$3
2101146
245
1 0
$a
Biomedical imaging and therapy with physically and physiologically tailored magnetic nanoparticles.
300
$a
184 p.
500
$a
Source: Dissertation Abstracts International, Volume: 75-05(E), Section: B.
500
$a
Adviser: Kannan M. Krishnan.
502
$a
Thesis (Ph.D.)--University of Washington, 2013.
520
$a
Magnetic particle imaging (MPI) and magnetic fluid hyperthermia (MFH) are emerging imaging and therapy approaches that have the potential to improve diagnostic safety and disease management of heart disease and cancer - the number 1 and 2 leading causes of deaths in the United States. MPI promises real-time, tomographic and quantitative imaging of superparamagnetic iron oxide nanoparticle (SPION) tracers distributed in vivo, and is targeted to offer a safer angiography alternative for its first clinical application. MFH uses ac-fields to dissipate heat from SPIONs that can be delivered locally to promote hyperthermia therapy (~42°C) in cancer cells.
520
$a
Both technologies use safe radiofrequency magnetic fields to exploit the fundamental magnetic relaxation properties of superparamagnetic iron oxide nanoparticles (SPIONs), which must be tailored for optimal imaging in the case of MPI, and maximum hyperthermia potency in the case of MFH. Furthermore, the magnetic core and shell of SPIONs are both central to the optimization process; the shell, in particular, bridges the translational gap between the optimized core and its safe and effective use in the physiological environment. Unfortunately, existing SPIONs that were originally designed as MRI contrast agents lack the basic physical properties that enable the clinical translation of MPI and MFH.
520
$a
In this work, the core and shell of monodisperse SPIONs were optimized in concert to accomplish two equally important objectives: (1) biocompatibility, and (2) MPI and MFH efficacy of SPIONs in physiological environments. Critically, it was found that the physical and physiological responses of SPIONs are coupled, and impacting one can have consequences on the other. It was shown that the poly(ethylene glycol) (PEG)-based shell when properly optimized reduced protein adsorption to SPION surface and phagocytic uptake in macrophages - both prerequisites for designing long-circulating SPIONs. In MPI, tailoring the surface coating reduced protein adsorption and improved colloidal stability, which were critical in retaining the magnetization relaxation properties of the SPIONs. The improvements in surface coatings enabled the use of larger SPION cores (> 20 nm core diameter), which were used to demonstrate benchmark-imaging performance in some of the world's first MPI scanners at Philips Medical Imaging and University of California, Berkeley. In MFH, it was shown for the first time that optimization of heat loss from SPIONs (W/g) is possible by tailoring the core size and size distribution for the given ac-field conditions. Biodistribution and blood circulation studies in mice showed that SPIONs accumulated primarily in the liver and spleen with minimal renal involvement, and demonstrated gradual clearance. Circulation time was evaluated using the MPI signal detected over time in blood, which offered insight on the relevant circulation time for angiography applications. In comparison with carboxy-dextran coated ResovistRTM SPIONs, the PEG-coated SPIONs developed in this work circulated substantially longer; furthermore, reducing the hydrodynamic diameter showed a 4.5x improvement in blood half-life.
520
$a
The work presented in this thesis demonstrates that the combined effort in optimizing the core and shell properties of SPIONs enhances biocompatibility and efficacy, with the in vivo studies providing critical feedback on the success (or failure) of the optimization process. Future work will entail designing functionalized SPIONs for targeting specific disease sites, which will further enable the molecular level diagnosis and therapy of diseases.
590
$a
School code: 0250.
650
4
$a
Engineering, Materials Science.
$3
1017759
650
4
$a
Health Sciences, Radiology.
$3
1019076
650
4
$a
Engineering, Biomedical.
$3
1017684
690
$a
0794
690
$a
0574
690
$a
0541
710
2
$a
University of Washington.
$b
Materials Science and Engineering.
$3
2094236
773
0
$t
Dissertation Abstracts International
$g
75-05B(E).
790
$a
0250
791
$a
Ph.D.
792
$a
2013
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3608958
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9259656
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login