Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Tactile sensing and display for robo...
~
Gwilliam, James C.
Linked to FindBook
Google Book
Amazon
博客來
Tactile sensing and display for robot-assisted minimally invasive surgery: Detecting lumps in soft tissue.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Tactile sensing and display for robot-assisted minimally invasive surgery: Detecting lumps in soft tissue./
Author:
Gwilliam, James C.
Description:
265 p.
Notes:
Source: Dissertation Abstracts International, Volume: 74-12(E), Section: B.
Contained By:
Dissertation Abstracts International74-12B(E).
Subject:
Engineering, Biomedical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3573079
ISBN:
9781303422225
Tactile sensing and display for robot-assisted minimally invasive surgery: Detecting lumps in soft tissue.
Gwilliam, James C.
Tactile sensing and display for robot-assisted minimally invasive surgery: Detecting lumps in soft tissue.
- 265 p.
Source: Dissertation Abstracts International, Volume: 74-12(E), Section: B.
Thesis (Ph.D.)--The Johns Hopkins University, 2013.
An important task in clinical diagnosis and surgery is detecting and localizing hard lumps in the soft tissues of the body. Since these lumps are embedded beneath the tissue surface and typically not visible, they must be found through palpation. During open procedures, lumps can be located with relative ease since the surgeon receives natural tactile (cutaneous) feedback while palpating directly with the fingers. In contrast, lump detection becomes considerably more challenging during robot-assisted minimally invasive surgery (RMIS), because distributed tactile information is not sensed or displayed to the surgeon. Artificial tactile feedback (ATF) systems have been proposed to restore tactile information during RMIS that could improve intra-operative assessment and lump localization.
ISBN: 9781303422225Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Tactile sensing and display for robot-assisted minimally invasive surgery: Detecting lumps in soft tissue.
LDR
:03503nam a2200301 4500
001
1963646
005
20141007080200.5
008
150210s2013 ||||||||||||||||| ||eng d
020
$a
9781303422225
035
$a
(MiAaPQ)AAI3573079
035
$a
AAI3573079
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Gwilliam, James C.
$3
2099946
245
1 0
$a
Tactile sensing and display for robot-assisted minimally invasive surgery: Detecting lumps in soft tissue.
300
$a
265 p.
500
$a
Source: Dissertation Abstracts International, Volume: 74-12(E), Section: B.
500
$a
Adviser: Allison Okamura.
502
$a
Thesis (Ph.D.)--The Johns Hopkins University, 2013.
520
$a
An important task in clinical diagnosis and surgery is detecting and localizing hard lumps in the soft tissues of the body. Since these lumps are embedded beneath the tissue surface and typically not visible, they must be found through palpation. During open procedures, lumps can be located with relative ease since the surgeon receives natural tactile (cutaneous) feedback while palpating directly with the fingers. In contrast, lump detection becomes considerably more challenging during robot-assisted minimally invasive surgery (RMIS), because distributed tactile information is not sensed or displayed to the surgeon. Artificial tactile feedback (ATF) systems have been proposed to restore tactile information during RMIS that could improve intra-operative assessment and lump localization.
520
$a
This dissertation describes several studies aimed to improve and evaluate tactile feedback for RMIS lump detection: First, we evaluate the ability of humans and artificial tactile sensors to detect lumps in a constrained, passive, one-dimensional lump detection task. Using a classifier based on signal detection theory, we show that a tactile sensor can detect lumps at lower average applied pressures than a human finger. ii We show the effects of lump size, depth, tissue compliance, and palpation velocity on human and artificial lump detection thresholds. Second, we identify the neural mechanisms underlying lump detection in soft tissue, and demonstrate that firing rate encodes for lump depth, while spatial spread encodes for lump size. We con-dude that lump detection is based on a spatial population code of the SA1 afferents. Third, we develop a novel air-jet lump display that creates a lump percept by directing pressurized air through an aperture onto the finger. We quantitatively characterize the set of achievable pressure profiles and identify the display control mechanisms. Through psychophysical studies, we determine the just noticeable difference (JND) values for the display control parameters. Fourth, we develop an ATF system for teleoperated lump detection in soft tissue. We develop custom algorithms for lump detection and size estimation and show that the ATF system can reliably detect the presence and size of lumps in soft tissue and that the sizes are discriminable through tactile feedback from the air-jet display. Collectively, this dissertation demonstrates the potential of tactile feedback as applied to RMIS, though the methods described can be generally abstracted to traditional minimally invasive approaches as well.
590
$a
School code: 0098.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Engineering, Robotics.
$3
1018454
650
4
$a
Health Sciences, Surgery.
$3
1681670
690
$a
0541
690
$a
0771
690
$a
0576
710
2
$a
The Johns Hopkins University.
$b
Biomedical Engineering.
$3
2099947
773
0
$t
Dissertation Abstracts International
$g
74-12B(E).
790
$a
0098
791
$a
Ph.D.
792
$a
2013
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3573079
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9258644
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login