Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Luminescent sensor improvements: Ma...
~
Rowe, Heather Marie.
Linked to FindBook
Google Book
Amazon
博客來
Luminescent sensor improvements: Materials to techniques.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Luminescent sensor improvements: Materials to techniques./
Author:
Rowe, Heather Marie.
Description:
154 p.
Notes:
Source: Dissertation Abstracts International, Volume: 65-04, Section: B, page: 1885.
Contained By:
Dissertation Abstracts International65-04B.
Subject:
Chemistry, Physical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3131446
Luminescent sensor improvements: Materials to techniques.
Rowe, Heather Marie.
Luminescent sensor improvements: Materials to techniques.
- 154 p.
Source: Dissertation Abstracts International, Volume: 65-04, Section: B, page: 1885.
Thesis (Ph.D.)--University of Virginia, 2004.
Multiple approaches to improving luminescent sensor technology have been pursued. The first approach seeks novel sensor-polymer support systems to elucidate the significant, yet not fully characterized, role of polymer supports in sensor performance and to detect specific analytes including copper(II) ions and carbon dioxide. Both detection systems utilize luminescent ruthenium(II) complexes as the sensor molecule. The polymers used contain a hydrophobic binding region for the sensor molecule.Subjects--Topical Terms:
560527
Chemistry, Physical.
Luminescent sensor improvements: Materials to techniques.
LDR
:03557nmm 2200313 4500
001
1865729
005
20041222104215.5
008
130614s2004 eng d
035
$a
(UnM)AAI3131446
035
$a
AAI3131446
040
$a
UnM
$c
UnM
100
1
$a
Rowe, Heather Marie.
$3
1953155
245
1 0
$a
Luminescent sensor improvements: Materials to techniques.
300
$a
154 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-04, Section: B, page: 1885.
500
$a
Adviser: James Demas.
502
$a
Thesis (Ph.D.)--University of Virginia, 2004.
520
$a
Multiple approaches to improving luminescent sensor technology have been pursued. The first approach seeks novel sensor-polymer support systems to elucidate the significant, yet not fully characterized, role of polymer supports in sensor performance and to detect specific analytes including copper(II) ions and carbon dioxide. Both detection systems utilize luminescent ruthenium(II) complexes as the sensor molecule. The polymers used contain a hydrophobic binding region for the sensor molecule.
520
$a
The first sensing model consisted of a sensor complex (Ru-cyclam = [Ru(Ph 2phen)2(4-cyclamCH2(4'-Me)bpy)]Cl 2 where Ph2phen = 4,7-diphenyl-1,10-phenanthroline, bpy = 2,2'-bipyridine, and cyclam = 1,4,8,11-tetraazacyclotetradecane), a quenching analyte (copper(II) ions), and a polymer support. The second sensing system was designed to measure carbon dioxide-induced pH changes. This model system consisted of a sensor complex ([Ru(Ph2phen)2(DEAM 2bpy)]2+ where DEAM2bpy = 4,4' -bis (diethylaminomethyl)-2,2' bipyridine), a phase transfer agent, and a polymer support.
520
$a
To further the understanding of the gas diffusion measurements and interactions between sensor molecules and polymer supports, a computerized intensity-based diffusion coefficient instrument (CDI) was designed and constructed. Design considerations, a series of mathematical simulations, and experimental results for automated luminescence-based oxygen diffusion coefficient measurements are discussed.
520
$a
Sensor technology can also be improved by modifying existing measurement methods. Gated phase-modulation (GPM) fluorometry was developed to measure lifetimes from relative long-lived samples without or with reduced errors from scattered light and short-lived fluorescences. The use of an offset time prior to gating the detector on mitigates errors from fluorescence bleed-through into the detection period or a slow excitation source turn off for relative long-lived samples. Theory and experimental results are presented.
520
$a
An adaptation of GPM fluorimetry allows for self-referenced intensity measurements. A combination of theory and experimental results demonstrated the validity of GPM and its adaptation. As the concentration of the analyte changed, the corresponding sensor intensity changes can be quantified through several schemes including digitization of the signal and digital integration or AC methods. The adaptation requires the use of a reference emitter and an analyte-sensitive molecule with very different lifetimes. The fluctuations of the excitation source and any optical transmission changes are eliminated by ratioing the sensor emission to the reference emission.
590
$a
School code: 0246.
650
4
$a
Chemistry, Physical.
$3
560527
650
4
$a
Chemistry, Analytical.
$3
586156
690
$a
0494
690
$a
0486
710
2 0
$a
University of Virginia.
$3
645578
773
0
$t
Dissertation Abstracts International
$g
65-04B.
790
1 0
$a
Demas, James,
$e
advisor
790
$a
0246
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3131446
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9184605
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login