Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
SWAP & PAWS - Quantum Logic Gates in...
~
Yue, Kenneth.
Linked to FindBook
Google Book
Amazon
博客來
SWAP & PAWS - Quantum Logic Gates in Biomedical Magnetic Resonance.
Record Type:
Electronic resources : Monograph/item
Title/Author:
SWAP & PAWS - Quantum Logic Gates in Biomedical Magnetic Resonance./
Author:
Yue, Kenneth.
Description:
158 p.
Notes:
Source: Dissertation Abstracts International, Volume: 64-10, Section: B, page: 4824.
Contained By:
Dissertation Abstracts International64-10B.
Subject:
Biophysics, Medical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3110843
SWAP & PAWS - Quantum Logic Gates in Biomedical Magnetic Resonance.
Yue, Kenneth.
SWAP & PAWS - Quantum Logic Gates in Biomedical Magnetic Resonance.
- 158 p.
Source: Dissertation Abstracts International, Volume: 64-10, Section: B, page: 4824.
Thesis (Ph.D.)--University of California, Los Angeles, 2004.
Two-dimensional magnetic resonance spectroscopy has shown the promise to detect more metabolites of low concentrations and resolve overlapping resonances in the one-dimensional counterpart. However, besides a longer acquisition time, there are other tradeoffs including an intrinsic signal loss of above half and a broad peakshape due to the effects of the mixing pulse in some correlation techniques. When the mixing pulse is replaced by an isotropic mixing module as used in total correlation or homonuclear Hartmann-Hahn spectroscopy, higher sensitivity and resolution can be achieved. However, the implementations of such a module commonly require a train of high-power radiofrequency pulses which deposits a large amount of energy within a short period of time, heating body tissues up to a temperature beyond the safety threshold. The current study aims at reducing the power deposition while retaining the similar effects of such mixing module by a universal swap (SWAP) quantum logic gate. The SWAP module can be implemented in magnetic resonance using only seven pulses, including two slice-selective pulses. By appending the module to a slice-selective excitation pulse and introducing some incremental delays, a volume-localized, two-dimensional sequence is developed. This novel quantum logic sequence earns a new name called PAWS for achieving power abatement with SWAP. Theoretical analyses suggest that PAWS spectra have intrinsically higher signal gains or even full signal recovery for some spin systems, and have better peakshapes due to improved phase characteristics. Moreover, a series of phantom experiments demonstrates some special features of PAWS. For examples, dominant singlets in water and N-acetylaspartate resonances can be reduced in the N-type region but preserved in the P-type region within the same spectrum. Coupled-spin signals in alanine and lactate can be withdrawn from their diagonals and deposited back into their cross peaks while the dominant lipid signals are preserved. Fine structures of the well-known methylene singlet in creatine resonances can be readily resolved even in an isotropic solution. Furthermore, spatially imbedded product operator (SIMPO) formalism, developed here based on the popular product operator formalism, makes the theoretical expositions more concise and efficient for the practitioners in the field of biomedical magnetic resonance.Subjects--Topical Terms:
1017681
Biophysics, Medical.
SWAP & PAWS - Quantum Logic Gates in Biomedical Magnetic Resonance.
LDR
:03304nmm 2200277 4500
001
1864975
005
20041216133907.5
008
130614s2004 eng d
035
$a
(UnM)AAI3110843
035
$a
AAI3110843
040
$a
UnM
$c
UnM
100
1
$a
Yue, Kenneth.
$3
1952438
245
1 0
$a
SWAP & PAWS - Quantum Logic Gates in Biomedical Magnetic Resonance.
300
$a
158 p.
500
$a
Source: Dissertation Abstracts International, Volume: 64-10, Section: B, page: 4824.
500
$a
Chair: Michael Albert Thomas.
502
$a
Thesis (Ph.D.)--University of California, Los Angeles, 2004.
520
$a
Two-dimensional magnetic resonance spectroscopy has shown the promise to detect more metabolites of low concentrations and resolve overlapping resonances in the one-dimensional counterpart. However, besides a longer acquisition time, there are other tradeoffs including an intrinsic signal loss of above half and a broad peakshape due to the effects of the mixing pulse in some correlation techniques. When the mixing pulse is replaced by an isotropic mixing module as used in total correlation or homonuclear Hartmann-Hahn spectroscopy, higher sensitivity and resolution can be achieved. However, the implementations of such a module commonly require a train of high-power radiofrequency pulses which deposits a large amount of energy within a short period of time, heating body tissues up to a temperature beyond the safety threshold. The current study aims at reducing the power deposition while retaining the similar effects of such mixing module by a universal swap (SWAP) quantum logic gate. The SWAP module can be implemented in magnetic resonance using only seven pulses, including two slice-selective pulses. By appending the module to a slice-selective excitation pulse and introducing some incremental delays, a volume-localized, two-dimensional sequence is developed. This novel quantum logic sequence earns a new name called PAWS for achieving power abatement with SWAP. Theoretical analyses suggest that PAWS spectra have intrinsically higher signal gains or even full signal recovery for some spin systems, and have better peakshapes due to improved phase characteristics. Moreover, a series of phantom experiments demonstrates some special features of PAWS. For examples, dominant singlets in water and N-acetylaspartate resonances can be reduced in the N-type region but preserved in the P-type region within the same spectrum. Coupled-spin signals in alanine and lactate can be withdrawn from their diagonals and deposited back into their cross peaks while the dominant lipid signals are preserved. Fine structures of the well-known methylene singlet in creatine resonances can be readily resolved even in an isotropic solution. Furthermore, spatially imbedded product operator (SIMPO) formalism, developed here based on the popular product operator formalism, makes the theoretical expositions more concise and efficient for the practitioners in the field of biomedical magnetic resonance.
590
$a
School code: 0031.
650
4
$a
Biophysics, Medical.
$3
1017681
650
4
$a
Health Sciences, Radiology.
$3
1019076
650
4
$a
Engineering, Biomedical.
$3
1017684
690
$a
0760
690
$a
0574
690
$a
0541
710
2 0
$a
University of California, Los Angeles.
$3
626622
773
0
$t
Dissertation Abstracts International
$g
64-10B.
790
1 0
$a
Thomas, Michael Albert,
$e
advisor
790
$a
0031
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3110843
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9183850
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login